127 related articles for article (PubMed ID: 23551567)
1. Interference of cerebrospinal fluid white blood cell counts performed on the Sysmex XT-4000i by yeast and bacteria.
Omuse G; Makau P
Int J Lab Hematol; 2013 Dec; 35(6):e5-7. PubMed ID: 23551567
[No Abstract] [Full Text] [Related]
2. Cell analysis in cerebrospinal fluid (CSF) using Sysmex® hematology analyzers XT-4000i and XE-5000: evaluation with CSF controls of the Joint German Society for Clinical Chemistry and Laboratory Medicine (DGKL).
Kleine TO; Nebe CT; Löwer C; Geilenkeuser WJ; Dorn-Beineke A
Cytometry A; 2012 Mar; 81(3):255-64. PubMed ID: 22253065
[TBL] [Abstract][Full Text] [Related]
3. [Assessment of the capability of the fluid model of automatic blood cell analyzer in white blood cell count and classification].
Shen J; Chen Y; Wang GZ; Ma L; Han CW
Zhonghua Xue Ye Xue Za Zhi; 2013 Jul; 34(7):629-31. PubMed ID: 23906462
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of Sysmex UF-1000i for use in cerebrospinal fluid analysis.
Nanos NE; Delanghe JR
Clin Chim Acta; 2008 Jun; 392(1-2):30-3. PubMed ID: 18348868
[TBL] [Abstract][Full Text] [Related]
5. Automated flow cytometric analysis of cerebrospinal fluid.
Van Acker JT; Delanghe JR; Langlois MR; Taes YE; De Buyzere ML; Verstraete AG
Clin Chem; 2001 Mar; 47(3):556-60. PubMed ID: 11238311
[TBL] [Abstract][Full Text] [Related]
6. Automated flow cytometric analysis of blood cells in cerebrospinal fluid.
Sandhaus LM
Am J Clin Pathol; 2005 Jan; 123(1):154; author reply 154. PubMed ID: 15762292
[No Abstract] [Full Text] [Related]
7. Automated white blood cell counts in cerebrospinal fluid using the body fluid mode on the platform Sysmex XE-5000.
Li A; Grönlund E; Brattsand G
Scand J Clin Lab Invest; 2014 Nov; 74(8):673-80. PubMed ID: 25180445
[TBL] [Abstract][Full Text] [Related]
8. Flow cytometric characterization of cerebrospinal fluid cells.
de Graaf MT; de Jongste AH; Kraan J; Boonstra JG; Sillevis Smitt PA; Gratama JW
Cytometry B Clin Cytom; 2011 Sep; 80(5):271-81. PubMed ID: 21567940
[TBL] [Abstract][Full Text] [Related]
9. Improved software on the Sysmex XE-5000 BF mode for counting leukocytes in cerebrospinal fluid.
Fleming C; Brouwer R; Lindemans J; de Jonge R
Clin Chem Lab Med; 2013 Apr; 51(4):e61-3. PubMed ID: 23037515
[No Abstract] [Full Text] [Related]
10. Automated flow cytometric analysis of blood cells in cerebrospinal fluid: analytic performance.
Aune MW; Becker JL; Brugnara C; Canfield W; Dorfman DM; Fiehn W; Fischer G; Fitzpatrick P; Flaming TH; Henriksen HK; Kunicka JE; Lackner KJ; Minchello E; Mullenix PA; Myers M; Petersen A; Ternstrom W; Wilson SJ
Am J Clin Pathol; 2004 May; 121(5):690-700. PubMed ID: 15151209
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of cell counting and leukocyte differentiation in cerebrospinal fluid controls using hematology analyzers by the German Society for Clinical Chemistry and Laboratory Medicine.
Kleine TO; Nebe CT; Löwer C; Lehmitz R; Geilenkeuser WJ; Kruse R; Dorn-Beineke A
Clin Chem Lab Med; 2010 Jun; 48(6):839-48. PubMed ID: 20441472
[TBL] [Abstract][Full Text] [Related]
12. [Differential leukocyte counting with a new automatic particle counter].
Tvede K; Hansen FR; Wimberley PD; Partoft T
Ugeskr Laeger; 1987 Dec; 149(52):3535-9. PubMed ID: 3433568
[No Abstract] [Full Text] [Related]
13. Is the blood basophil count sufficiently precise, accurate, and specific?: three automated hematology instruments and flow cytometry compared.
Amundsen EK; Henriksson CE; Holthe MR; Urdal P
Am J Clin Pathol; 2012 Jan; 137(1):86-92. PubMed ID: 22180481
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of Mindray BC-6800 body fluid mode for automated cerebrospinal fluid cell counting.
Buoro S; Seghezzi M; Mecca T; Vavassori M; Crippa A; La Gioia A
Clin Chem Lab Med; 2016 Nov; 54(11):1799-1810. PubMed ID: 27101549
[TBL] [Abstract][Full Text] [Related]
15. [Automated cerebrospinal fluid cell count. A valuable contribution to diagnostics of brain diseases].
Wall M; Mattsson N; Zetterberg H; Blennow K
Lakartidningen; 2011 Oct 5-11; 108(40):1972-3. PubMed ID: 22111239
[No Abstract] [Full Text] [Related]
16. Performance evaluation of the Sysmex XE-5000 hematology analyzer for white blood cell analysis in cerebrospinal fluid.
Perné A; Hainfellner JA; Womastek I; Haushofer A; Szekeres T; Schwarzinger I
Arch Pathol Lab Med; 2012 Feb; 136(2):194-8. PubMed ID: 22288968
[TBL] [Abstract][Full Text] [Related]
17. Characteristic scattergram of white blood cells obtained using the Pentra MS CRP hematology analyzer in a patient with neutral lipid storage disease.
Inaba T; Nomura N; Takahashi M; Ishizuka K; Yoshika K; Yuasa S; Nakanishi M; Fujita N
Lab Hematol; 2013 Dec; 19(4):22-4. PubMed ID: 24370872
[No Abstract] [Full Text] [Related]
18. Modifications of haematology analyzers to improve cell counting and leukocyte differentiating in cerebrospinal fluid controls of the Joint German Society for Clinical Chemistry and Laboratory Medicine.
Kleine TO; Nebe CT; Löwer C; Lehmitz R; Kruse R; Geilenkeuser WJ; Dorn-Beineke A
Cytometry A; 2009 Aug; 75(8):688-91. PubMed ID: 19526484
[TBL] [Abstract][Full Text] [Related]
19. Automated cerebrospinal fluid cytology.
Heller T; Nagel I; Ehrlich B; Bähr M; Strik H
Anal Quant Cytol Histol; 2008 Jun; 30(3):139-44. PubMed ID: 18630838
[TBL] [Abstract][Full Text] [Related]
20. Low level leucocyte counting (LLLC) in blood products.
Brando B; Barnett D; Arroz MJ
J Biol Regul Homeost Agents; 2003; 17(3):234-40. PubMed ID: 14524608
[No Abstract] [Full Text] [Related]
[Next] [New Search]