BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 23556876)

  • 1. Accuracy verification of infrared marker-based dynamic tumor-tracking irradiation using the gimbaled x-ray head of the Vero4DRT (MHI-TM2000).
    Mukumoto N; Nakamura M; Sawada A; Suzuki Y; Takahashi K; Miyabe Y; Kaneko S; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2013 Apr; 40(4):041706. PubMed ID: 23556876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictive uncertainty in infrared marker-based dynamic tumor tracking with Vero4DRT.
    Akimoto M; Nakamura M; Mukumoto N; Tanabe H; Yamada M; Matsuo Y; Monzen H; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2013 Sep; 40(9):091705. PubMed ID: 24007138
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Positional accuracy of novel x-ray-image-based dynamic tumor-tracking irradiation using a gimbaled MV x-ray head of a Vero4DRT (MHI-TM2000).
    Mukumoto N; Nakamura M; Sawada A; Takahashi K; Miyabe Y; Takayama K; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2012 Oct; 39(10):6287-96. PubMed ID: 23039664
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term stability assessment of a 4D tumor tracking system integrated into a gimbaled linear accelerator.
    Akimoto M; Nakamura M; Miyabe Y; Mukumoto N; Yokota K; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2015 Sep; 16(5):373–380. PubMed ID: 26699328
    [TBL] [Abstract][Full Text] [Related]  

  • 5. WE-G-213CD-09: Quality Assurance of the Surrogate Signal-Based Dynamic Tumor-Tracking Irradiation with Vero4DRT (MHI-TM2000).
    Mukumoto N; Nakamura M; Sawada A; Suzuki Y; Takahashi K; Miyabe Y; Kaneko S; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2012 Jun; 39(6Part28):3972. PubMed ID: 28519631
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality assurance of a gimbaled head swing verification using feature point tracking.
    Miura H; Ozawa S; Enosaki T; Kawakubo A; Hosono F; Yamada K; Nagata Y
    J Appl Clin Med Phys; 2017 Jan; 18(1):49-52. PubMed ID: 28291928
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of audio instruction on tracking errors using a four-dimensional image-guided radiotherapy system.
    Nakamura M; Sawada A; Mukumoto N; Takahashi K; Mizowaki T; Kokubo M; Hiraoka M
    J Appl Clin Med Phys; 2013 Sep; 14(5):255-64. PubMed ID: 24036880
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system.
    Ebe K; Sugimoto S; Utsunomiya S; Kagamu H; Aoyama H; Court L; Tokuyama K; Baba R; Ogihara Y; Ichikawa K; Toyama J
    Med Phys; 2015 Aug; 42(8):4745-54. PubMed ID: 26233202
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Baseline correction of a correlation model for improving the prediction accuracy of infrared marker-based dynamic tumor tracking.
    Akimoto M; Nakamura M; Mukumoto N; Yamada M; Tanabe H; Ueki N; Kaneko S; Matsuo Y; Mizowaki T; Kokubo M; Hiraoka M
    J Appl Clin Med Phys; 2015 Mar; 16(2):4896. PubMed ID: 26103167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head.
    Ono T; Miyabe Y; Yamada M; Shiinoki T; Sawada A; Kaneko S; Monzen H; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2014 Mar; 41(3):031705. PubMed ID: 24593709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of tumor amplitude and frequency on 4D modeling of Vero4DRT system.
    Miura H; Ozawa S; Hayata M; Tsuda S; Yamada K; Nagata Y
    Rep Pract Oncol Radiother; 2017; 22(4):290-294. PubMed ID: 28507458
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization of the x-ray monitoring angle for creating a correlation model between internal and external respiratory signals.
    Akimoto M; Nakamura M; Mukumoto N; Yamada M; Ueki N; Matsuo Y; Sawada A; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2012 Oct; 39(10):6309-15. PubMed ID: 23039666
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of the correlation modeling period on the prediction accuracy of infrared marker-based dynamic tumor tracking using a gimbaled X-ray head.
    Nakamura M; Akimoto M; Mukumoto N; Yamada M; Tanabe H; Ueki N; Matsuo Y; Mizowaki T; Kokubo M; Hiraoka M
    Phys Med; 2015 May; 31(3):204-9. PubMed ID: 25639590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a four-dimensional Monte Carlo dose calculation system for real-time tumor-tracking irradiation with a gimbaled X-ray head.
    Ishihara Y; Nakamura M; Miyabe Y; Mukumoto N; Matsuo Y; Sawada A; Kokubo M; Mizowaki T; Hiraoka M
    Phys Med; 2017 Mar; 35():59-65. PubMed ID: 28216331
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intrafractional tracking accuracy in infrared marker-based hybrid dynamic tumour-tracking irradiation with a gimballed linac.
    Mukumoto N; Nakamura M; Yamada M; Takahashi K; Tanabe H; Yano S; Miyabe Y; Ueki N; Kaneko S; Matsuo Y; Mizowaki T; Sawada A; Kokubo M; Hiraoka M
    Radiother Oncol; 2014 May; 111(2):301-5. PubMed ID: 24746563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of image guided motion management methods in lung cancer radiotherapy.
    Zhuang L; Yan D; Liang J; Ionascu D; Mangona V; Yang K; Zhou J
    Med Phys; 2014 Mar; 41(3):031911. PubMed ID: 24593729
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery.
    Speidel MA; Wilfley BP; Hsu A; Hristov D
    Med Phys; 2012 Apr; 39(4):2163-9. PubMed ID: 22482637
    [TBL] [Abstract][Full Text] [Related]  

  • 18. GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.
    Kauweloa KI; Ruan D; Park JC; Sandhu A; Kim GY; Pawlicki T; Watkins WT; Song B; Song WY
    Med Phys; 2012 Jan; 39(1):492-502. PubMed ID: 22225320
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.
    Campbell WG; Miften M; Jones BL
    Med Phys; 2017 Feb; 44(2):364-374. PubMed ID: 28035655
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 4D ultrasound real-time tracking system for external beam radiotherapy of upper abdominal lesions under breath-hold.
    Sihono DS; Vogel L; Weiß C; Thölking J; Wenz F; Lohr F; Boda-Heggemann J; Wertz H
    Strahlenther Onkol; 2017 Mar; 193(3):213-220. PubMed ID: 27921121
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.