These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 23557098)

  • 21. Split fractures of the lateral tibial plateau: evaluation of three fixation methods.
    Koval KJ; Polatsch D; Kummer FJ; Cheng D; Zuckerman JD
    J Orthop Trauma; 1996; 10(5):304-8. PubMed ID: 8814570
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Contribution of minimally invasive bone augmentation to primary stabilization of the osteosynthesis of Schatzker type II tibial plateau fractures: Balloon vs bone tamp.
    Vendeuvre T; Grunberg M; Germaneau A; Maloubier F; Faure JP; Gayet LE; Rigoard P; Brèque C
    Clin Biomech (Bristol, Avon); 2018 Nov; 59():27-33. PubMed ID: 30142475
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Arthroscopic Fixation of Tibial Eminence Fractures: A Biomechanical Comparative Study of Screw, Suture, and Suture Anchor.
    Li J; Yu Y; Liu C; Su X; Liao W; Li Z
    Arthroscopy; 2018 May; 34(5):1608-1616. PubMed ID: 29397286
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques.
    Gan Y; Xu D; Ding J; Xu Y
    Knee Surg Sports Traumatol Arthrosc; 2012 May; 20(5):909-15. PubMed ID: 21863305
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of additional fixation in tibial plateau impression fractures treated with balloon reduction and cement augmentation.
    Mayr R; Attal R; Zwierzina M; Blauth M; Schmoelz W
    Clin Biomech (Bristol, Avon); 2015 Oct; 30(8):847-51. PubMed ID: 26094777
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical analysis of different osteosyntheses and the combination with bone substitute in tibial head depression fractures.
    Jordan MC; Zimmermann C; Gho SA; Frey SP; Blunk T; Meffert RH; Hoelscher-Doht S
    BMC Musculoskelet Disord; 2016 Jul; 17():287. PubMed ID: 27422525
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study.
    Cift H; Cetik O; Kalaycioglu B; Dirikoglu MH; Ozkan K; Eksioglu F
    Orthop Traumatol Surg Res; 2010 May; 96(3):263-7. PubMed ID: 20488145
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model.
    Walsh MP; Wijdicks CA; Parker JB; Hapa O; LaPrade RF
    Am J Sports Med; 2009 Jan; 37(1):160-7. PubMed ID: 18832342
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Bone substitute first or screws first? A biomechanical comparison of two operative techniques for tibial-head depression fractures.
    Hoelscher-Doht S; Jordan MC; Bonhoff C; Frey S; Blunk T; Meffert RH
    J Orthop Sci; 2014 Nov; 19(6):978-83. PubMed ID: 25113667
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.
    Yang SW; Kuo SM; Chang SJ; Su TS; Chen HH; Renn JH; Lin TS
    Orthopedics; 2013 Oct; 36(10):e1316-21. PubMed ID: 24093710
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
    Cullen AB; Curtiss S; Lee MA
    J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Reverse Anterior Cruciate Ligament Reconstruction Fixation: A Biomechanical Comparison Study of Tibial Cross-Pin and Femoral Interference Screw Fixation.
    Lawley RJ; Klein SE; Chudik SC
    Arthroscopy; 2017 Mar; 33(3):625-632. PubMed ID: 27939069
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.
    Knobe M; Altgassen S; Maier KJ; Gradl-Dietsch G; Kaczmarek C; Nebelung S; Klos K; Kim BS; Gueorguiev B; Horst K; Buecking B
    Int Orthop; 2018 Feb; 42(2):409-418. PubMed ID: 28780597
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The use of bidirectional rapid reductor in minimally invasive treatment of bicondylar tibial plateau fractures: preliminary radiographic and clinical results.
    Chang H; Zheng Z; Yu Y; Shao J; Zhang Y
    BMC Musculoskelet Disord; 2018 Nov; 19(1):419. PubMed ID: 30497475
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?
    García Vélez DA; Headford M; Suresh KV; Liberatos PM; Bledsoe G; Revak T
    Injury; 2022 Oct; 53(10):3109-3114. PubMed ID: 36028376
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Bioabsorbable sutures versus screw fixation of displaced tibial eminence fractures: a biomechanical study.
    Senekovic V; Balazic M
    Eur J Orthop Surg Traumatol; 2014 Feb; 24(2):209-16. PubMed ID: 23412317
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation.
    Dehoust J; Münch M; Seide K; Barth T; Frosch KH
    Eur J Trauma Emerg Surg; 2020 Dec; 46(6):1257-1266. PubMed ID: 33179130
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An intact fibula may contribute to allow early weight bearing in surgically treated tibial plateau fractures.
    Carrera I; Gelber PE; Chary G; Gomez Masdeu M; González Ballester MA; Monllau JC; Noailly J
    Knee Surg Sports Traumatol Arthrosc; 2018 Mar; 26(3):756-761. PubMed ID: 28255659
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.
    Dougherty PJ; Kim DG; Meisterling S; Wybo C; Yeni Y
    J Orthop Trauma; 2008 Jul; 22(6):399-403. PubMed ID: 18594304
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.