These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
153 related articles for article (PubMed ID: 23576916)
1. Bone-on-bone versus hardware impingement in total hips: a biomechanical study. Elkins JM; Pedersen DR; Callaghan JJ; Brown TD Iowa Orthop J; 2012; 32():17-21. PubMed ID: 23576916 [TBL] [Abstract][Full Text] [Related]
2. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement. Kluess D; Martin H; Mittelmeier W; Schmitz KP; Bader R Med Eng Phys; 2007 May; 29(4):465-71. PubMed ID: 16901743 [TBL] [Abstract][Full Text] [Related]
4. The impingement-dislocation risk of total hip replacement: effects of cup orientation and patient maneuvers. Ghaffari M; Nickmanesh R; Tamannaee N; Farahmand F Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():6801-4. PubMed ID: 23367491 [TBL] [Abstract][Full Text] [Related]
5. Morbid obesity may increase dislocation in total hip patients: a biomechanical analysis. Elkins JM; Daniel M; Pedersen DR; Singh B; Yack HJ; Callaghan JJ; Brown TD Clin Orthop Relat Res; 2013 Mar; 471(3):971-80. PubMed ID: 22907474 [TBL] [Abstract][Full Text] [Related]
6. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA. Murphy WS; Yun HH; Hayden B; Kowal JH; Murphy SB Clin Orthop Relat Res; 2018 Feb; 476(2):325-335. PubMed ID: 29529664 [TBL] [Abstract][Full Text] [Related]
7. Detecting cause of dislocation after total hip arthroplasty by patient-specific four-dimensional motion analysis. Miki H; Sugano N; Yonenobu K; Tsuda K; Hattori M; Suzuki N Clin Biomech (Bristol, Avon); 2013 Feb; 28(2):182-6. PubMed ID: 23219052 [TBL] [Abstract][Full Text] [Related]
8. Impingement with total hip replacement. Malik A; Maheshwari A; Dorr LD J Bone Joint Surg Am; 2007 Aug; 89(8):1832-42. PubMed ID: 17671025 [TBL] [Abstract][Full Text] [Related]
9. Dislocation after total hip arthroplasty: implant design and orientation. Barrack RL J Am Acad Orthop Surg; 2003; 11(2):89-99. PubMed ID: 12670135 [TBL] [Abstract][Full Text] [Related]
10. Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective. Fabry C; Langlois J; Hamadouche M; Bader R Int Orthop; 2016 May; 40(5):901-6. PubMed ID: 26429197 [TBL] [Abstract][Full Text] [Related]
11. Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty. Nadzadi ME; Pedersen DR; Callaghan JJ; Brown TD Clin Biomech (Bristol, Avon); 2002 Jan; 17(1):32-40. PubMed ID: 11779644 [TBL] [Abstract][Full Text] [Related]
12. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors. Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482 [TBL] [Abstract][Full Text] [Related]
13. Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis. Terrier A; Latypova A; Guillemin M; Parvex V; Guyen O Int Orthop; 2017 Mar; 41(3):551-556. PubMed ID: 28070611 [TBL] [Abstract][Full Text] [Related]
14. Risk factors for dislocation after revision total hip arthroplasty with a dual-mobility cup. Matched case-control study (16 cases vs. 48 controls). Huten D; Fournier Y; Gicquel T; Bertho P; Basselot F; Hamadouche M Orthop Traumatol Surg Res; 2019 Nov; 105(7):1303-1309. PubMed ID: 31153859 [TBL] [Abstract][Full Text] [Related]
15. Impingement and dislocation in total hip arthroplasty: mechanisms and consequences. Brown TD; Elkins JM; Pedersen DR; Callaghan JJ Iowa Orthop J; 2014; 34():1-15. PubMed ID: 25328453 [TBL] [Abstract][Full Text] [Related]
17. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis. Elkins JM; Callaghan JJ; Brown TD Clin Orthop Relat Res; 2014 Feb; 472(2):529-42. PubMed ID: 24218160 [TBL] [Abstract][Full Text] [Related]
18. Cadaver-Specific Models for Finite-Element Analysis of Iliopsoas Impingement in Dual-Mobility Hip Implants. Zumbrunn T; Patel R; Duffy MP; Rubash HE; Malchau H; Freiberg AA; Muratoglu OK; Varadarajan KM J Arthroplasty; 2018 Nov; 33(11):3574-3580. PubMed ID: 30029930 [TBL] [Abstract][Full Text] [Related]
19. Implementing capsule representation in a total hip dislocation finite element model. Stewart KJ; Pedersen DR; Callaghan JJ; Brown TD Iowa Orthop J; 2004; 24():1-8. PubMed ID: 15296198 [TBL] [Abstract][Full Text] [Related]
20. Factors affecting impingement and dislocation after total hip arthroplasty - Computer simulation analysis. Shoji T; Ota Y; Saka H; Murakami H; Takahashi W; Yamasaki T; Yasunaga Y; Iwamori H; Adachi N Clin Biomech (Bristol, Avon); 2020 Dec; 80():105151. PubMed ID: 32836081 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]