BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 23580703)

  • 1. In vitro comparison of neonatal suction catheters using simulated 'pea soup' meconium.
    Zareen Z; Hawkes CP; Krickan ER; Dempsey EM; Ryan CA
    Arch Dis Child Fetal Neonatal Ed; 2013 May; 98(3):F241-3. PubMed ID: 23580703
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Meconium-stained amniotic fluid and respiratory complications: impact of selective tracheal suction.
    Yoder BA
    Obstet Gynecol; 1994 Jan; 83(1):77-84. PubMed ID: 8272313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intratracheal catheter suction removes the same volume of meconium with less impact on desaturation compared with meconium aspirator in meconium aspiration syndrome.
    Akazawa Y; Ishida T; Baba A; Hiroma T; Nakamura T
    Early Hum Dev; 2010 Aug; 86(8):499-502. PubMed ID: 20634007
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing the Effectiveness of a Novel Suction Set-up Using an Adult Endotracheal Tube Connected to a Meconium Aspirator vs. a Traditional Yankauer Suction Instrument.
    Kei J; Mebust DP
    J Emerg Med; 2017 Apr; 52(4):433-437. PubMed ID: 27751699
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Removing meconium from infant tracheae. What works best?
    Bent RC; Wiswell TE; Chang A
    Am J Dis Child; 1992 Sep; 146(9):1085-9. PubMed ID: 1514556
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oropharyngeal and nasopharyngeal suctioning of meconium-stained neonates before delivery of their shoulders: multicentre, randomised controlled trial.
    Vain NE; Szyld EG; Prudent LM; Wiswell TE; Aguilar AM; Vivas NI
    Lancet; 2004 Aug 14-20; 364(9434):597-602. PubMed ID: 15313360
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of bulb versus DeLee suction at deliveries complicated by meconium stained amniotic fluid.
    Locus P; Yeomans E; Crosby U
    Am J Perinatol; 1990 Jan; 7(1):87-91. PubMed ID: 2294916
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intratracheal suctioning, systemic infection, and the meconium aspiration syndrome.
    Wiswell TE; Henley MA
    Pediatrics; 1992 Feb; 89(2):203-6. PubMed ID: 1734384
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intrapartum suctioning of meconium: comparative efficacy of bulb syringe and De Lee catheter.
    Cohen-Addad N; Chatterjee M; Bautista A
    J Perinatol; 1987; 7(2):111-3. PubMed ID: 3505604
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tracheal suctioning improves gas exchange but not hemodynamics in asphyxiated lambs with meconium aspiration.
    Lakshminrusimha S; Mathew B; Nair J; Gugino SF; Koenigsknecht C; Rawat M; Nielsen L; Swartz DD
    Pediatr Res; 2015 Feb; 77(2):347-55. PubMed ID: 25406897
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A meconium suctioning device that is safe and practical.
    Coraggio MJ; Alexander HG; Roscelli JD
    J Perinatol; 1989 Dec; 9(4):427-9. PubMed ID: 2593017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Refining the method of therapeutic lung lavage in meconium aspiration syndrome.
    Dargaville PA; Copnell B; Tingay DG; Gordon MJ; Mills JF; Morley CJ
    Neonatology; 2008; 94(3):160-3. PubMed ID: 18612212
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A retrospective review of tracheal suction at birth in neonates with meconium aspiration syndrome.
    Manickam D
    Med J Malaysia; 1992 Mar; 47(1):60-4. PubMed ID: 1387452
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of bulb versus DeLee suctioning of meconium may have dangerous implications.
    Hein HA
    Am J Perinatol; 1991 Nov; 8(6):422-3. PubMed ID: 1814309
    [No Abstract]   [Full Text] [Related]  

  • 15. Does DeLee suction at the perineum prevent meconium aspiration syndrome?
    Falciglia HS; Henderschott C; Potter P; Helmchen R
    Am J Obstet Gynecol; 1992 Nov; 167(5):1243-9. PubMed ID: 1442972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Failure to prevent meconium aspiration syndrome.
    Falciglia HS
    Obstet Gynecol; 1988 Mar; 71(3 Pt 1):349-53. PubMed ID: 3347418
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Suction Rates Between a Standard Yankauer, a Commercial Large-Bore Suction Device, and a Makeshift Large-Bore Suction Device.
    Nikolla DA; King B; Heslin A; Carlson JN
    J Emerg Med; 2021 Sep; 61(3):265-270. PubMed ID: 34006421
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In utero meconium suctioning may prevent meconium aspiration.
    Petrikovsky B
    Fetal Diagn Ther; 2004; 19(6):533-5. PubMed ID: 15539879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Meconium stained amniotic fluid: antenatal, intrapartum and neonatal attributes.
    Gupta V; Bhatia BD; Mishra OP
    Indian Pediatr; 1996 Apr; 33(4):293-7. PubMed ID: 8772903
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delivery room management of meconium staining of the amniotic fluid and the development of meconium aspiration syndrome.
    Hageman JR; Conley M; Francis K; Stenske J; Wolf I; Santi V; Farrell EE
    J Perinatol; 1988; 8(2):127-31. PubMed ID: 3193263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.