These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
289 related articles for article (PubMed ID: 23581399)
1. Improving the management of warfarin in aged-care facilities utilising innovative technology: a proof-of-concept study. Bereznicki LR; Jackson SL; Kromdijk W; Gee P; Fitzmaurice K; Bereznicki BJ; Peterson GM Int J Pharm Pract; 2014 Feb; 22(1):84-91. PubMed ID: 23581399 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of warfarin management with international normalized ratio self-testing and online remote monitoring and management plus low-dose vitamin k with genomic considerations: a pilot study. Bussey HI; Bussey M; Bussey-Smith KL; Frei CR Pharmacotherapy; 2013 Nov; 33(11):1136-46. PubMed ID: 24038412 [TBL] [Abstract][Full Text] [Related]
3. Accuracy and clinical usefulness of the CoaguChek S and XS Point of Care devices when starting warfarin in a hospital outreach setting. Sobieraj-Teague M; Daniel D; Farrelly B; Coghlan D; Gallus A Thromb Res; 2009 Apr; 123(6):909-13. PubMed ID: 19042011 [TBL] [Abstract][Full Text] [Related]
4. Pilot study of a novel patient self-management program for warfarin therapy using venipuncture-acquired international normalized ratio monitoring. Simmons BJ; Jenner KM; Delate T; Clark NP; Kurz D; Witt DM Pharmacotherapy; 2012 Dec; 32(12):1078-84. PubMed ID: 23112110 [TBL] [Abstract][Full Text] [Related]
5. Improving the outcomes of anticoagulation in rural Australia: an evaluation of pharmacist-assisted monitoring of warfarin therapy. Jackson SL; Peterson GM; Bereznicki LR; Misan GM; Jupe DM; Vial JH J Clin Pharm Ther; 2005 Aug; 30(4):345-53. PubMed ID: 15985048 [TBL] [Abstract][Full Text] [Related]
6. Supervised patient self-testing of warfarin therapy using an online system. Bereznicki LR; Jackson SL; Peterson GM J Med Internet Res; 2013 Jul; 15(7):e138. PubMed ID: 23853350 [TBL] [Abstract][Full Text] [Related]
7. Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring. Bereznicki LR; Jackson SL; Peterson GM; Jeffrey EC; Marsden KA; Jupe DM J Clin Pathol; 2007 Mar; 60(3):311-4. PubMed ID: 16751303 [TBL] [Abstract][Full Text] [Related]
8. Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin. Bauman ME; Black KL; Massicotte MP; Bauman ML; Kuhle S; Howlett-Clyne S; Cembrowski GS; Bajzar L Thromb Haemost; 2008 Jun; 99(6):1097-103. PubMed ID: 18521514 [TBL] [Abstract][Full Text] [Related]
9. Improving anticoagulation therapy using point-of-care testing and a standardized protocol. Franke CA; Dickerson LM; Carek PJ Ann Fam Med; 2008; 6 Suppl 1(Suppl 1):S28-32. PubMed ID: 18195305 [TBL] [Abstract][Full Text] [Related]
10. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95). Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081 [TBL] [Abstract][Full Text] [Related]
11. Home medicines reviews in Australian war veterans taking warfarin do not influence international normalised ratio control. Bereznicki LR; van Tienen EC; Stafford A Intern Med J; 2016 Mar; 46(3):288-94. PubMed ID: 26602177 [TBL] [Abstract][Full Text] [Related]
12. The clinical significance of differences between point-of-care and laboratory INR methods in over-anticoagulated patients. Lawrie AS; Hills J; Longair I; Green L; Gardiner C; Machin SJ; Cohen H Thromb Res; 2012 Jul; 130(1):110-4. PubMed ID: 21937093 [TBL] [Abstract][Full Text] [Related]
13. A team-based approach to warfarin management in long term care: a feasibility study of the MEDeINR electronic decision support system. Papaioannou A; Kennedy CC; Campbell G; Stroud JB; Wang L; Dolovich L; Crowther MA; BMC Geriatr; 2010 Jun; 10():38. PubMed ID: 20537178 [TBL] [Abstract][Full Text] [Related]
14. The economic costs of routine INR monitoring in infants and children--examining point-of-care devices used within the home setting compared to traditional anticoagulation clinic monitoring. Gaw JR; Crowley S; Monagle P; Jones S; Newall F Thromb Res; 2013 Jul; 132(1):26-31. PubMed ID: 23746471 [TBL] [Abstract][Full Text] [Related]
15. Correlation of point-of-care International Normalized Ratio to laboratory International Normalized Ratio in hemodialysis patients taking warfarin. Hoel RW; Albright RC; Beyer LK; Santrach PJ; Magtibay DL; Everson SL; McBane RD Clin J Am Soc Nephrol; 2009 Jan; 4(1):99-104. PubMed ID: 18987294 [TBL] [Abstract][Full Text] [Related]
16. Feasibility, cost-effectiveness and patients' acceptance of point-of-care INR testing in a hospital-based anticoagulation clinic. Kong MC; Lim TG; Ng HJ; Chan YH; Lee LH Ann Hematol; 2008 Nov; 87(11):905-10. PubMed ID: 18604535 [TBL] [Abstract][Full Text] [Related]
18. Inaccuracy of point-of-care international normalized ratio in rivaroxaban-treated patients. Baruch L; Sherman O Ann Pharmacother; 2013 Sep; 47(9):1210-2. PubMed ID: 24259738 [TBL] [Abstract][Full Text] [Related]
19. Optimizing warfarin and dual oral anticoagulation practices in an academic clinic during a merger amid the COVID-19 pandemic in a marginalized population. Bahuva R; Jordan J; Pokharel Y; Reynolds JL; Bakhai S Int J Qual Health Care; 2024 Oct; 36(3):. PubMed ID: 39300952 [TBL] [Abstract][Full Text] [Related]