BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 23590768)

  • 1. Operative treatment of communited olecranon fractures using tension-band wiring and miniplate augmentation.
    Oh HK; Choo SK; Lee CS; Song JG
    Orthopedics; 2013 Apr; 36(4):275-8. PubMed ID: 23590768
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques.
    Tarallo L; Mugnai R; Adani R; Capra F; Zambianchi F; Catani F
    Arch Orthop Trauma Surg; 2014 Aug; 134(8):1107-14. PubMed ID: 24935660
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Olecranon fractures with sagittal splits treated with dual fixation.
    Morwood MP; Ruch DS; Leversedge FJ; Mithani SK; Kamal RN; Richard MJ
    J Hand Surg Am; 2015 Apr; 40(4):711-5. PubMed ID: 25701490
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Outcomes of embedded rafting k-wire technique for intermediate articular fragment fixation in comminuted olecranon fractures.
    Cho JW; Oh JK; Um J; Sohn HS
    Arch Orthop Trauma Surg; 2022 Nov; 142(11):3327-3334. PubMed ID: 34554312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technique Using Isoelastic Tension Band for Treatment of Olecranon Fractures.
    Rajfer RA; Danoff JR; Yemul KS; Zouzias I; Rosenwasser MP
    Am J Orthop (Belle Mead NJ); 2015 Dec; 44(12):542-6. PubMed ID: 26665240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases.
    Fournet A; Boursier JF; Corbeau S; Decambron A; Viateau V; Fayolle P; Bedu AS; Leperlier D; Manassero M
    Vet Comp Orthop Traumatol; 2018 Jan; 31(1):53-61. PubMed ID: 29325193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Factors influencing K-wire migration in tension-band wiring of olecranon fractures.
    Saeed ZM; Trickett RW; Yewlett AD; Matthews TJ
    J Shoulder Elbow Surg; 2014 Aug; 23(8):1181-6. PubMed ID: 24875733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures.
    Midtgaard KS; Søreide E; Brattgjerd JE; Moatshe G; Madsen JE; Flugsrud GB
    J Shoulder Elbow Surg; 2020 Jun; 29(6):1242-1248. PubMed ID: 32139286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fixation of olecranon fractures and osteotomies using compression screws: a simple solution to a common problem. A study of cases.
    Haddad B; Khan W; Zaghloul A; Grimes L; Schenk W
    Ortop Traumatol Rehabil; 2013; 15(4):341-6. PubMed ID: 24431272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An off-loading triceps suture for augmentation of plate fixation in comminuted osteoporotic fractures of the olecranon.
    Izzi J; Athwal GS
    J Orthop Trauma; 2012 Jan; 26(1):59-61. PubMed ID: 22025265
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surgical technique in tension band wiring method for selected comminuted olecranon fractures.
    Okamoto M; Namba J; Kuriyama K; Miyamura S; Yokoi H; Yamamoto K
    Eur J Orthop Surg Traumatol; 2020 Feb; 30(2):237-242. PubMed ID: 31538271
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Proximal ulnar fractures in adults: a review of 163 cases.
    Niéto H; Billaud A; Rochet S; Lavoinne N; Loubignac F; Pietu G; Baroan C; Espie A; Bonnevialle P; Fabre T
    Injury; 2015 Jan; 46 Suppl 1():S18-23. PubMed ID: 26528935
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.
    Gruszka D; Arand C; Greenfield J; Nowak TE; Kuechle R; Kuhn S; Rommens PM
    Arch Orthop Trauma Surg; 2017 Dec; 137(12):1651-1658. PubMed ID: 28864862
    [TBL] [Abstract][Full Text] [Related]  

  • 14. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures.
    van der Linden SC; van Kampen A; Jaarsma RL
    J Shoulder Elbow Surg; 2012 Mar; 21(3):405-11. PubMed ID: 22036542
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Management of comminuted olecranon fractures with precut K-wires and tension band wiring.
    Suresh SS
    Tech Hand Up Extrem Surg; 2009 Jun; 13(2):82-4. PubMed ID: 19516132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics.
    Powell AJ; Farhan-Alanie OM; McGraw IWW
    Musculoskelet Surg; 2019 Aug; 103(2):155-160. PubMed ID: 30006804
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A rare complication of tension band fixation of olecranon osteotomy: Distal migration of K-wire.
    Köroğlu M; Karakaplan M; Ergen E; Eren M; Alyousef A; Özdeş HU; Aslantürk O
    Jt Dis Relat Surg; 2024 Apr; 35(2):439-442. PubMed ID: 38727126
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Treatment of olecranon fractures with 2.4- and 2.7-mm plating techniques.
    Wellman DS; Lazaro LE; Cymerman RM; Axelrad TW; Leu D; Helfet DL; Lorich DG
    J Orthop Trauma; 2015 Jan; 29(1):36-43. PubMed ID: 24824096
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Double tension band wiring for treatment of olecranon fractures.
    Kim W; Choi S; Yoon JO; Park HY; Kim SH; Kim JS
    J Hand Surg Am; 2014 Dec; 39(12):2438-43. PubMed ID: 25447004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Olecranon osteotomy fixation using a novel device: the olecranon sled.
    Iorio T; Wong JC; Patterson JD; Rekant MS
    Tech Hand Up Extrem Surg; 2013 Sep; 17(3):151-7. PubMed ID: 23970197
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.