  • 1. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 2. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms.
    Kowalski M; Ellenbogen KA; Wood MA; Friedman PL
    Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator].
    Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G
    Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Early automatic remote detection of combined lead insulation defect and ICD damage.
    Neuzil P; Taborsky M; Holy F; Wallbrueck K
    Europace; 2008 May; 10(5):556-7. PubMed ID: 18227352
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rise in ICD shock impedance: lead fracture or death?
    Stroobandt RX; Van Heuverswyn FE; Kucher A; Barold SS
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):1103-10. PubMed ID: 22734696
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection.
    Knops P; Theuns DA; Res JC; Jordaens L
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1276-85. PubMed ID: 19796344
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An Isolated and Transient Lead Impedance Alert as the Sole Indicator of ICD System Failure.
    Whittaker-Axon S; Breitenstein A; Finlay M
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):1022-5. PubMed ID: 27119619
    [No Abstract]   [Full Text] [Related]  

  • 10. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks.
    Tzeis S; Andrikopoulos G; Kolb C; Vardas PE
    Europace; 2008 Nov; 10(11):1256-65. PubMed ID: 18708639
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Near-Fatal ICD Lead Dysfunction with Implications for ICD Testing.
    Wutzler A; Attanasio P; Haverkamp W; Blaschke F
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):105-6. PubMed ID: 26519249
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The implantable cardioverter-defibrillator lead: principles, progress, and promises.
    Haqqani HM; Mond HG
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1336-53. PubMed ID: 19796348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impedance changes on defibrillation coils after atrial fibrillation ablation: lead damage or electromechanical interference?
    Vanga SR; Bommana S; Kroll M; Lakkireddy D
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e163-6. PubMed ID: 21029124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Terminology, characterization, and measurement of ICD defibrillation impedance.
    Barold SS; Herweg B
    J Electrocardiol; 2013; 46(6):660-2. PubMed ID: 24075508
    [No Abstract]   [Full Text] [Related]  

  • 17. "Cold can for a hot case": use of a coronary sinus shocking lead in association with cold can to achieve successful defibrillation.
    Hamid S; Khan S; Rinaldi CA
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):561-2. PubMed ID: 19335872
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement.
    Eckart RE; Hruczkowski TW; Stevenson WG; Epstein LM
    Pacing Clin Electrophysiol; 2006 Nov; 29(11):1273-6. PubMed ID: 17100683
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical experience and procedural outcomes associated with the DF4 implantable cardioverter defibrillator system: the SJ4 postapproval study.
    Cantillon DJ; Ha K; Styperek R; Jumrussirikul P; Mirro M; Wong W; Wilkoff BL
    Pacing Clin Electrophysiol; 2013 Jul; 36(7):855-62. PubMed ID: 23617316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
    Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K
    Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696
    [TBL] [Abstract][Full Text] [Related]  