BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 23596755)

  • 1. Fast track biopsy method: a rapid approach to preoperative diagnoses.
    Steri V; Farnedi A; Montinari E; Foschini MP
    Pathologica; 2010 Apr; 102(2):41-5. PubMed ID: 23596755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparative study on microwave and routine tissue processing.
    Babu TM; Malathi N; Magesh KT
    Indian J Dent Res; 2011; 22(1):50-5. PubMed ID: 21525677
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microwave-stimulated formaldehyde fixation of experimental renal biopsy tissues: computerised morphometric analysis of distortion artefacts.
    Looi LM; Loh KC
    Malays J Pathol; 2005 Jun; 27(1):23-7. PubMed ID: 16676689
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The fast-track biopsy (FTB): description of a rapid histology and immunohistochemistry method for evaluation of preoperative breast core biopsies.
    Ragazzini T; Magrini E; Cucchi MC; Foschini MP; Eusebi V
    Int J Surg Pathol; 2005 Jul; 13(3):247-52. PubMed ID: 16086079
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid supplementary fixation in frozen sections: microwave versus conventional fixation. A double-blind comparative study.
    Reed W; Erichsen A; Roald B
    Pathol Res Pract; 1991 Sep; 187(7):824-7. PubMed ID: 1754508
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microwave technique in histopathology and its comparison with the conventional technique.
    Chaudhari K; Chattopadhyay A; Dutta SK
    Indian J Pathol Microbiol; 2000 Oct; 43(4):387-94. PubMed ID: 11344600
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microwave applications in classical staining methods in formalin-fixed human brain tissue: a comparison between heating with microwave and conventional ovens.
    Feirabend HK; Ploeger S
    Eur J Morphol; 1991; 29(3):185-97. PubMed ID: 1726666
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cytological preparation.
    Brainard JA; Biscotti CV
    Monogr Clin Cytol; 2012; 21():10-6. PubMed ID: 22024580
    [No Abstract]   [Full Text] [Related]  

  • 9. [Microwaves in morphologic examinations: technologic progress or whim?].
    Niezabitowski A; Stachura J
    Patol Pol; 1991; 42(1):5-9. PubMed ID: 1726977
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simple method for fixation and microdissection of frozen fresh tissue sections for molecular cytogenetic analysis of cancers.
    Huang Q; Sacks PG; Mo J; McCormick SA; Iacob CE; Guo L; Schaefer S; Schantz SP
    Biotech Histochem; 2005; 80(3-4):147-56. PubMed ID: 16298900
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incorporation of microwave tissue processing into a routine pathology laboratory: impact on turnaround times and laboratory work patterns.
    Leong AS; Price D
    Pathology; 2004 Aug; 36(4):321-4. PubMed ID: 15370130
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combining microwave stabilization and microwave-stimulated fixation of brain tissue with microwave-stimulated staining.
    van Dorp R; Boon ME; Kok PG; Marani E
    Eur J Morphol; 1995 Apr; 33(2):164-73. PubMed ID: 7488521
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Will PAXgene substitute formalin? A morphological and molecular comparative study using a new fixative system.
    Belloni B; Lambertini C; Nuciforo P; Phillips J; Bruening E; Wong S; Dummer R
    J Clin Pathol; 2013 Feb; 66(2):124-35. PubMed ID: 23125305
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simple and rapid microwave-assisted hematoxylin and eosin staining method using 1,1,1 trichloroethane as a dewaxing and a clearing agent.
    Temel SG; Noyan S; Cavusoglu I; Kahveci Z
    Biotech Histochem; 2005; 80(3-4):123-32. PubMed ID: 16298897
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microwave histoprocessing of bone marrow trephine biopsies.
    Louw I; De Beer DP; Du Plessis MJ
    Histochem J; 1994 Jun; 26(6):487-94. PubMed ID: 7928402
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of clarity of nucleocytoplasmic differentiation of oral tissues processed by microwave and conventional methods.
    K SN; Patel S; Astekar M; Rao D
    Ann Diagn Pathol; 2012 Apr; 16(2):128-33. PubMed ID: 22050966
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microwave fixation provides rapid, primary fixation for light and electron microscopy and for immunohistochemistry and immunocytochemistry.
    Login GR; Schnitt SJ; Dvorak AM
    Eur J Morphol; 1991; 29(3):206-10. PubMed ID: 1726667
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Structural and antigenic preservation of plant samples by microwave-enhanced fixation, using dedicated hardware, minimizing heat-related effects.
    LerĂ­a F; Marco R; Medina FJ
    Microsc Res Tech; 2004 Sep; 65(1-2):86-100. PubMed ID: 15570593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accelerated staining technique using kitchen microwave oven.
    Mukunda A; Narayan TV; Shreedhar B; Shashidhara R; Mohanty L; Shenoy S
    Indian J Pathol Microbiol; 2015; 58(3):316-22. PubMed ID: 26275253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polyoma virus-associated cellular changes in the urine and bladder biopsy samples: a cytohistologic correlation.
    Herawi M; Parwani AV; Chan T; Ali SZ; Epstein JI
    Am J Surg Pathol; 2006 Mar; 30(3):345-50. PubMed ID: 16538054
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.