These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 2360106)

  • 1. [Extracorporeal circulation with auto-oxygenation in cardiac surgery].
    Gebauer I; Loksin LS; Styk J; Osipov VP; Baryseva IE; Ravíngerová T
    Rozhl Chir; 1990 Feb; 69(2):77-80. PubMed ID: 2360106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved biocompatibility of extracorporeal circulation by the use of auto-oxygenation instead of artificial oxygenator in perfusion circuit.
    Bochenek A; Religa Z; Kustosz R; Wnuk-Wojnar AM; Wnuk R; Wojnar J; Woś S; Wites M; Zembala M; Spyt T
    Nephrol Dial Transplant; 1991; 6 Suppl 3():75-80. PubMed ID: 1775272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Loss of thrombocytes in heart surgery with membrane and bubble oxygenators (author's transl)].
    Birnbaum D; Keilbach H; Bücherl ES
    Thoraxchir Vask Chir; 1977 Dec; 25(6):438-42. PubMed ID: 601767
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retrospective Analysis of Air Handling by Contemporary Oxygenators in the Setting of Cardiac Surgery.
    Benstoem C; Bleilevens C; Borchard R; Stoppe C; Goetzenich A; Autschbach R; Breuer T
    Ann Thorac Cardiovasc Surg; 2018 Oct; 24(5):230-237. PubMed ID: 29998925
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Open heart surgery under extracorporeal circulation (Lillehei-De Wall pump oxygenator system); our preliminary results].
    DUBOST C; HEIM DE BALSAC F; LENFANT C; GUERY J; PASSELECQ J; WEISS M; ROUANET J
    Acta Cardiol; 1957; 12(1):53-65. PubMed ID: 13424022
    [No Abstract]   [Full Text] [Related]  

  • 6. Phosphorylcholine or heparin coating for pediatric extracorporeal circulation causes similar biologic effects in neonates and infants.
    Böning A; Scheewe J; Ivers T; Friedrich C; Stieh J; Freitag S; Cremer JT
    J Thorac Cardiovasc Surg; 2004 May; 127(5):1458-65. PubMed ID: 15116008
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Xenon washout during in-vitro extracorporeal circulation using different oxygenators.
    Schirmer U; Reinelt H; Erber M; Schmidt M; Marx T
    J Clin Monit Comput; 2002; 17(3-4):211-5. PubMed ID: 12455738
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Membrane oxygenators or bubble oxygenators during extracorporeal circulation in heart surgery?].
    Loisance D
    Nouv Presse Med; 1978 Apr; 7(15):1304. PubMed ID: 662664
    [No Abstract]   [Full Text] [Related]  

  • 9. [Membrane oxygenators in cardiac surgery: progress].
    Loisance D; Ledouarin B; O'Byrne P; Cachera JP; Galey JJ; Michel JP; Renguin J; Polette D
    Ann Anesthesiol Fr; 1976; 17(12):1306-14. PubMed ID: 16518
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Trends in the choice of anesthesia in heart surgery and in the composition of gas flow in artificial oxygenator ventilation during extracorporal circulation].
    Pagni E; Perna AM; De Angeli D; Noferi D; Poggiali C; Wiechmann V
    Minerva Anestesiol; 1977 Mar; 43(5):267-74. PubMed ID: 301618
    [No Abstract]   [Full Text] [Related]  

  • 11. [Widening of the limits of the pump oxygenator system of Lillehei-De Wall for bloodless heart surgery; experimental study of two modifications facilitating use of extracorporeal circulation in adults].
    LENFANT C; WEISS M; ROUANET J; DUBOST C
    Presse Med (1893); 1956 Jun; 64(50):1162-4. PubMed ID: 13350097
    [No Abstract]   [Full Text] [Related]  

  • 12. [The Brazilian disposable bubble oxygenator. 5000 operations with the DMG model].
    Cunha MA; Santos GS; Moraes DJ; Feitosa LA; Abilio FM; Aragão E; Cisne E; Freitas E; Camargo M; Brito JD; Debiase H
    Arq Bras Cardiol; 1980 Oct; 35(4):283-6. PubMed ID: 7213108
    [No Abstract]   [Full Text] [Related]  

  • 13. [Evaluation of the efficiency and capacity of the bubble oxygenator].
    de Magalhães HP
    Arq Bras Cardiol; 1979 Aug; 33(2):100-5. PubMed ID: 539919
    [No Abstract]   [Full Text] [Related]  

  • 14. Heparin cofactor activity during and after extracorporeal circulation with bubble and membrane oxygenators.
    Weiss M; Blass J; Leau A; Verriest C
    Biomedicine; 1977 Oct; 27(7):248-9. PubMed ID: 73390
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Personal observations with application of auto-oxygenation techniques in the surgical management of coronary disease].
    Bochenek A; Religa Z; Zembala M; Kustosz R; Woś S; Bochenek A; Toczek K; Skiba J; Wilczyński M; Bachowski R
    Kardiol Pol; 1990 Mar; 33(3):173-8. PubMed ID: 2082071
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Comparative clinical experience with membrane oxygenators and bubble oxygenators in open-heart surgery in childhood].
    Romano S; Niguidula F
    Minerva Chir; 1978 Feb; 33(4):219-20. PubMed ID: 652177
    [No Abstract]   [Full Text] [Related]  

  • 17. [Heart surgery with extracorporeal circulation using alpha membrane oxygenator. Personal experience in 150 cases].
    Vieira GL; da Silva RR; de Oliveira HG; Ribeiro S; Pavan WL; Jorge JC; de Carvalho LF; Rabello SC
    Arq Bras Cardiol; 1980 Oct; 35(4):287-90. PubMed ID: 7213109
    [No Abstract]   [Full Text] [Related]  

  • 18. [Clinical experience with a polypropyrene hollow fiber oxygenator--comparative study of Termo Capiox II and Shiley bubble oxygenator].
    Matsukura H; Takeda H; Gohda T; Uzawa S; Tachiki T; Matsunami O; Sakai K; Kawakami T; Tanabe T; Muramatsu A
    Nihon Kyobu Geka Gakkai Zasshi; 1984 Oct; 32(10):1804-11. PubMed ID: 6440929
    [No Abstract]   [Full Text] [Related]  

  • 19. The Society Lecture. European Society for Cardiovascular Surgery Meeting, Montpellier, France, September 1992. The birth of open-heart surgery: then the golden years.
    Lillehei CW
    Cardiovasc Surg; 1994 Jun; 2(3):308-17. PubMed ID: 8049965
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Use of a membrane oxygenator in extracorporeal circulation in the child. Preliminary conclusions].
    Aubert J; Frigiola A; Pannetier A; Couvélly JP
    Ann Anesthesiol Fr; 1977; 18(1):22-8. PubMed ID: 16540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.