These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1160 related articles for article (PubMed ID: 23601116)
1. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating. Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116 [TBL] [Abstract][Full Text] [Related]
3. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures. Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures. Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777 [TBL] [Abstract][Full Text] [Related]
5. Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis. Cunningham DJ; Lawrence JE; Kovvur M; Turner KE; Oppizzi G; Xu D; Zhang LQ; Johnson DJ; Mittwede P; Sepehri A; Brand J; O'Toole RV; Gage MJ Injury; 2024 Jun; 55(6):111540. PubMed ID: 38622039 [TBL] [Abstract][Full Text] [Related]
6. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary? Penny P; Swords M; Heisler J; Cien A; Sands A; Cole P Injury; 2016 Aug; 47(8):1761-9. PubMed ID: 27264277 [TBL] [Abstract][Full Text] [Related]
7. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures. Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426 [TBL] [Abstract][Full Text] [Related]
8. The management of complex fractures of the proximal tibia with minimal intra-articular impaction in fragility patients using intramedullary nailing and compression bolts. Garnavos C; Lasanianos NG Injury; 2011 Oct; 42(10):1066-72. PubMed ID: 21489525 [TBL] [Abstract][Full Text] [Related]
9. Retropatellar nailing and condylar bolts for complex fractures of the tibial plateau: technique, pilot study and rationale. Garnavos C Injury; 2014 Jul; 45(7):1099-104. PubMed ID: 24513218 [TBL] [Abstract][Full Text] [Related]
10. Biomechanical analysis of operative methods in the treatment of extra-articular fracture of the proximal tibia. Lee SM; Oh CW; Oh JK; Kim JW; Lee HJ; Chon CS; Lee BJ; Kyung HS Clin Orthop Surg; 2014 Sep; 6(3):312-7. PubMed ID: 25177457 [TBL] [Abstract][Full Text] [Related]
11. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study. Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909 [TBL] [Abstract][Full Text] [Related]
12. Biomechanical analysis comparing titanium elastic nails with locked plating in two simulated pediatric femur fracture models. Porter SE; Booker GR; Parsell DE; Weber MD; Russell GV; Woodall J; Wagner M; Neubauer T J Pediatr Orthop; 2012 Sep; 32(6):587-93. PubMed ID: 22892620 [TBL] [Abstract][Full Text] [Related]
13. Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. Nadkarni B; Srivastav S; Mittal V; Agarwal S J Trauma; 2008 Aug; 65(2):482-6. PubMed ID: 18695487 [TBL] [Abstract][Full Text] [Related]
14. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model. Cullen AB; Curtiss S; Lee MA J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical analysis of bicondylar tibial plateau fixation: how does lateral locking plate fixation compare to dual plate fixation? Higgins TF; Klatt J; Bachus KN J Orthop Trauma; 2007 May; 21(5):301-6. PubMed ID: 17485994 [TBL] [Abstract][Full Text] [Related]
16. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures. Chen F; Huang X; Ya Y; Ma F; Qian Z; Shi J; Guo S; Yu B J Orthop Surg Res; 2018 Jan; 13(1):12. PubMed ID: 29338748 [TBL] [Abstract][Full Text] [Related]
18. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures. Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228 [TBL] [Abstract][Full Text] [Related]
19. Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study. Cift H; Cetik O; Kalaycioglu B; Dirikoglu MH; Ozkan K; Eksioglu F Orthop Traumatol Surg Res; 2010 May; 96(3):263-7. PubMed ID: 20488145 [TBL] [Abstract][Full Text] [Related]
20. Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: a mechanical comparison of locking and nonlocking single and dual plating methods. Yoo BJ; Beingessner DM; Barei DP J Trauma; 2010 Jul; 69(1):148-55. PubMed ID: 20622588 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]