These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 23606167)

  • 1. Quantitative MRI analysis of menisci using biexponential T2* fitting with a variable echo time sequence.
    Juras V; Apprich S; Zbýň Š; Zak L; Deligianni X; Szomolanyi P; Bieri O; Trattnig S
    Magn Reson Med; 2014 Mar; 71(3):1015-23. PubMed ID: 23606167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.
    Lee YH; Suh JS; Grodzki D
    Magn Reson Imaging; 2016 Feb; 34(2):75-80. PubMed ID: 26435460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fat-suppressed volume isotropic turbo spin echo acquisition (VISTA) MR imaging in evaluating radial and root tears of the meniscus: focusing on reader-defined axial reconstruction.
    Lim D; Lee YH; Kim S; Song HT; Suh JS
    Eur J Radiol; 2013 Dec; 82(12):2296-302. PubMed ID: 24074646
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of T2* mapping between regular echo time and ultrashort echo time with 3D cones at 3 tesla for knee meniscus.
    Yi J; Lee YH; Song HT; Suh JS
    Medicine (Baltimore); 2018 Nov; 97(48):e13443. PubMed ID: 30508961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Short T2 tissue imaging with the Pointwise Encoding Time reduction with Radial Acquisition (PETRA) sequence: the additional value of fat saturation and subtraction in the meniscus.
    Lee YH; Suh JS; Grodzki D
    Magn Reson Imaging; 2015 May; 33(4):385-9. PubMed ID: 25614216
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Orientation dependence and decay characteristics of T
    Hager B; Walzer SM; Deligianni X; Bieri O; Berg A; Schreiner MM; Zalaudek M; Windhager R; Trattnig S; Juras V
    Magn Reson Med; 2019 Feb; 81(2):921-933. PubMed ID: 30269374
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid in vivo multicomponent T2 mapping of human knee menisci.
    Liu F; Samsonov A; Wilson JJ; Blankenbaker DG; Block WF; Kijowski R
    J Magn Reson Imaging; 2015 Nov; 42(5):1321-8. PubMed ID: 25847733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Meniscal calcifications: morphologic and quantitative evaluation by using 2D inversion-recovery ultrashort echo time and 3D ultrashort echo time 3.0-T MR imaging techniques--feasibility study.
    Omoumi P; Bae WC; Du J; Diaz E; Statum S; Bydder GM; Chung CB
    Radiology; 2012 Jul; 264(1):260-8. PubMed ID: 22723564
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation.
    Kijowski R; Davis KW; Blankenbaker DG; Woods MA; Del Rio AM; De Smet AA
    Skeletal Radiol; 2012 Feb; 41(2):169-78. PubMed ID: 21399933
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-Tesla magnetic resonance imaging of the meniscus of the knee: What about equivocal errors?
    Van Dyck P; Vanhoenacker FM; Gielen JL; Dossche L; Weyler J; Parizel PM
    Acta Radiol; 2010 Apr; 51(3):296-301. PubMed ID: 20105094
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo MRI assessment of knee cartilage in the medial meniscal tear model of osteoarthritis in rats.
    Xie Z; Liachenko S; Chiao PC; Carvajal-Gonzalez S; Bove S; Bocan T
    Med Image Comput Comput Assist Interv; 2010; 13(Pt 3):57-64. PubMed ID: 20879383
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Macromolecular fraction (MMF) from 3D ultrashort echo time cones magnetization transfer (3D UTE-Cones-MT) imaging predicts meniscal degeneration and knee osteoarthritis.
    Zhang X; Ma YJ; Wei Z; Wu M; Ashir A; Jerban S; Li S; Chang EY; Du J
    Osteoarthritis Cartilage; 2021 Aug; 29(8):1173-1180. PubMed ID: 33882334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. UTE-T2∗ mapping detects sub-clinical meniscus injury after anterior cruciate ligament tear.
    Williams A; Qian Y; Golla S; Chu CR
    Osteoarthritis Cartilage; 2012 Jun; 20(6):486-94. PubMed ID: 22306000
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bilaminar pattern of tibial condyle cartilage layer on the fat-suppressed 3D gradient echo images: artifact or structural and biochemical difference in composition of cartilage?
    Trattnig S; Mlynárik V; Jung B; Bader T; Sulzbacher I; Herneth A; Gaisch R; Puig S
    Magn Reson Imaging; 2001 Feb; 19(2):187-92. PubMed ID: 11358656
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of Meniscal Healing Status by Magnetic Resonance Imaging T2 Mapping After Meniscal Repair.
    Yamasaki S; Hashimoto Y; Nishida Y; Teraoka T; Terai S; Takigami J; Nakamura H
    Am J Sports Med; 2020 Mar; 48(4):853-860. PubMed ID: 32167835
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The role of T2-weighted fast-spin-echo imaging in the diagnosis of meniscal tears.
    White LM; Schweitzer ME; Johnson WJ; Amster BJ; Oliveri MP; Russell K
    J Magn Reson Imaging; 1996; 6(6):874-7. PubMed ID: 8956131
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Advanced morphological 3D magnetic resonance observation of cartilage repair tissue (MOCART) scoring using a new isotropic 3D proton-density, turbo spin echo sequence with variable flip angle distribution (PD-SPACE) compared to an isotropic 3D steady-state free precession sequence (True-FISP) and standard 2D sequences.
    Welsch GH; Zak L; Mamisch TC; Paul D; Lauer L; Mauerer A; Marlovits S; Trattnig S
    J Magn Reson Imaging; 2011 Jan; 33(1):180-8. PubMed ID: 21182137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Positive contrast MR imaging of tendons, ligaments, and menisci by subtraction of signals from a double echo steady state sequence (Sub-DESS).
    Martirosian P; Schraml C; Springer F; Schwenzer NF; Würslin C; Schick F; Deimling M
    Magn Reson Med; 2014 Jan; 71(1):294-301. PubMed ID: 23400875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A three-dimensional quantitative method to measure meniscus shape, position, and signal intensity using MR images: a pilot study and preliminary results in knee osteoarthritis.
    Wirth W; Frobell RB; Souza RB; Li X; Wyman BT; Le Graverand MP; Link TM; Majumdar S; Eckstein F
    Magn Reson Med; 2010 May; 63(5):1162-71. PubMed ID: 20432287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delayed gadolinium-enhanced MRI of the meniscus (dGEMRIM) in patients with knee osteoarthritis: relation with meniscal degeneration on conventional MRI, reproducibility, and correlation with dGEMRIC.
    van Tiel J; Kotek G; Reijman M; Bos PK; Bron EE; Klein S; Verhaar JA; Krestin GP; Weinans H; Oei EH
    Eur Radiol; 2014 Sep; 24(9):2261-70. PubMed ID: 24816941
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.