These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
216 related articles for article (PubMed ID: 23616225)
1. Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers. De la Parra-Colín P; Garza-León M; Barrientos-Gutierrez T Int Ophthalmol; 2014 Feb; 34(1):27-33. PubMed ID: 23616225 [TBL] [Abstract][Full Text] [Related]
2. Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes. Kumar M; Shetty R; Jayadev C; Rao HL; Dutta D Indian J Ophthalmol; 2017 Apr; 65(4):288-294. PubMed ID: 28513492 [TBL] [Abstract][Full Text] [Related]
3. Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using galilei, Pentacam, and Sirius devices. Anayol MA; Güler E; Yağci R; Şekeroğlu MA; Ylmazoğlu M; Trhş H; Kulak AE; Ylmazbaş P Cornea; 2014 Jun; 33(6):582-6. PubMed ID: 24763122 [TBL] [Abstract][Full Text] [Related]
4. Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements. Sel S; Stange J; Kaiser D; Kiraly L Cont Lens Anterior Eye; 2017 Oct; 40(5):318-322. PubMed ID: 28342729 [TBL] [Abstract][Full Text] [Related]
7. Comparison of corneal measurements using two different Scheimpflug analyzers in Sirius and Pentacam devices. Abdi P; Atighehchian M; Farsiani AR Sci Rep; 2023 Oct; 13(1):16956. PubMed ID: 37805659 [TBL] [Abstract][Full Text] [Related]
8. Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography. Ryu S; Yoon SH; Jun I; Seo KY; Kim EK; Kim TI Korean J Ophthalmol; 2022 Jun; 36(3):264-273. PubMed ID: 35527529 [TBL] [Abstract][Full Text] [Related]
9. Comparison of anterior segment measurements using Sirius Topographer Duman R; Çetinkaya E; Duman R; Dogan M; Sabaner MC Indian J Ophthalmol; 2018 Mar; 66(3):402-406. PubMed ID: 29480251 [TBL] [Abstract][Full Text] [Related]
10. Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetry. Huang J; Savini G; Hu L; Hoffer KJ; Lu W; Feng Y; Yang F; Hu X; Wang Q J Cataract Refract Surg; 2013 Feb; 39(2):219-24. PubMed ID: 23218819 [TBL] [Abstract][Full Text] [Related]
11. Repeatability assessment of anterior segment measurements in myopic patients using an anterior segment OCT with placido corneal topography and agreement with a swept-source OCT. Wang H; Zhu LS; Pang CJ; Fan Q BMC Ophthalmol; 2024 Apr; 24(1):182. PubMed ID: 38649848 [TBL] [Abstract][Full Text] [Related]
12. Repeatability of Orbscan III for anterior segment parameters in normal eyes. Sharma M; Jain N; Koshy AS; Arora V; Lalgudi VG Indian J Ophthalmol; 2020 Dec; 68(12):2903-2905. PubMed ID: 33229667 [TBL] [Abstract][Full Text] [Related]
13. Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement. Aramberri J; Araiz L; Garcia A; Illarramendi I; Olmos J; Oyanarte I; Romay A; Vigara I J Cataract Refract Surg; 2012 Nov; 38(11):1934-49. PubMed ID: 22995705 [TBL] [Abstract][Full Text] [Related]
14. Repeatability, reproducibility, and agreement between three different Scheimpflug systems in measuring corneal and anterior segment biometry. Hernández-Camarena JC; Chirinos-Saldaña P; Navas A; Ramirez-Miranda A; de la Mota A; Jimenez-Corona A; Graue-Hernindez EO J Refract Surg; 2014 Sep; 30(9):616-21. PubMed ID: 25250418 [TBL] [Abstract][Full Text] [Related]
15. Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry. Çağlar Ç; Kocamış Sİ; Demir E; Durmuş M Int Ophthalmol; 2017 Jun; 37(3):491-498. PubMed ID: 27392914 [TBL] [Abstract][Full Text] [Related]
16. Repeatability and Agreement of Orbscan II, Pentacam HR, and Galilei Tomography Systems in Corneas With Keratoconus. Meyer JJ; Gokul A; Vellara HR; Prime Z; McGhee CN Am J Ophthalmol; 2017 Mar; 175():122-128. PubMed ID: 27993593 [TBL] [Abstract][Full Text] [Related]
17. Repeatability, Reproducibility, and Agreement of Two Scheimpflug-Placido Anterior Corneal Analyzers for Posterior Corneal Surface Measurement. Bao F; Savini G; Shu B; Zhu S; Gao R; Dang G; Yu A; Wang Q; Huang J J Refract Surg; 2017 Aug; 33(8):524-530. PubMed ID: 28787517 [TBL] [Abstract][Full Text] [Related]
18. A novel Hartman Shack-based topography system: repeatability and agreement for corneal power with Scheimpflug+Placido topographer and rotating prism auto-keratorefractor. Prakash G; Srivastava D; Choudhuri S Int Ophthalmol; 2015 Dec; 35(6):869-80. PubMed ID: 25820517 [TBL] [Abstract][Full Text] [Related]
19. Comparison of Anterior Segment Measurements With a Dual Scheimpflug Placido Corneal Topographer and a New Partial Coherence Interferometer in Keratoconic Eyes. Yağcı R; Kulak AE; Güler E; Tenlik A; Gürağaç FB; Hepşen İF Cornea; 2015 Sep; 34(9):1012-8. PubMed ID: 26203742 [TBL] [Abstract][Full Text] [Related]
20. Repeatability and agreement of three Scheimpflug-based imaging systems for measuring anterior segment parameters in keratoconus. Shetty R; Arora V; Jayadev C; Nuijts RM; Kumar M; Puttaiah NK; Kummelil MK Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):5263-8. PubMed ID: 25074774 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]