These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 23622652)

  • 21. Outcomes of Deceased Donor Kidney Transplantation Using Expanded Criteria Donor Kidneys Following Pulsatile Preservation.
    Basu A; Rosen LM; Tan HP; Fishbein J; Wu CM; Donaldson JB; Stuart S; Shah NA; McCauley J; Humar A; Shapiro R
    Cureus; 2019 Jul; 11(7):e5091. PubMed ID: 31523526
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evolving experience using kidneys from deceased donors with terminal acute kidney injury.
    Farney AC; Rogers J; Orlando G; al-Geizawi S; Buckley M; Farooq U; al-Shraideh Y; Stratta RJ
    J Am Coll Surg; 2013 Apr; 216(4):645-55; discussion 655-6. PubMed ID: 23395159
    [TBL] [Abstract][Full Text] [Related]  

  • 23. One-year results of a prospective, randomized trial comparing two machine perfusion devices used for kidney preservation.
    Wszola M; Kwiatkowski A; Diuwe P; Domagała P; Górski L; Kieszek R; Berman A; Perkowska-Ptasińska A; Durlik M; Pączek L; Chmura A
    Transpl Int; 2013 Nov; 26(11):1088-96. PubMed ID: 24033725
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Delayed graft function in renal transplant recipients: risk factors and impact on 1-year graft function: a single center analysis.
    Bronzatto EJ; da Silva Quadros KR; Santos RL; Alves-Filho G; Mazzali M
    Transplant Proc; 2009 Apr; 41(3):849-51. PubMed ID: 19376369
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hypothermic Machine Perfusion as a National Standard Preservation Method for Deceased Donor Kidneys.
    Brat A; de Vries KM; van Heurn EWE; Huurman VAL; de Jongh W; Leuvenink HGD; van Zuilen AD; Haase-Kromwijk BJJM; de Jonge J; Berger SP; Hofker SH
    Transplantation; 2022 May; 106(5):1043-1050. PubMed ID: 34172648
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact of machine perfusion after long static cold storage on delayed graft function incidence and duration and time to hospital discharge.
    Matos ACC; Requiao Moura LR; Borrelli M; Nogueira M; Clarizia G; Ongaro P; Durão MS; Pacheco-Silva A
    Clin Transplant; 2018 Jan; 32(1):. PubMed ID: 28972665
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Pulsatile perfusion reduces the risk of delayed graft function in deceased donor kidney transplants, irrespective of donor type and cold ischemic time.
    Gill J; Dong J; Eng M; Landsberg D; Gill JS
    Transplantation; 2014 Mar; 97(6):668-74. PubMed ID: 24637865
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The LifeLink Foundation and cadaver kidney transplantation in Tampa.
    LeFor WM; Wright CE; Bowers VD; Heinrichs DF; Shires DL
    Clin Transpl; 1999; ():149-58. PubMed ID: 11038633
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Hypothermic Machine Perfusion Versus Static Cold Storage in Deceased Donor Kidney Transplantation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.
    Peng P; Ding Z; He Y; Zhang J; Wang X; Yang Z
    Artif Organs; 2019 May; 43(5):478-489. PubMed ID: 30282122
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cold Pulsatile Machine Perfusion versus Static Cold Storage in Kidney Transplantation: A Single Centre Experience.
    Bellini MI; Charalampidis S; Herbert PE; Bonatsos V; Crane J; Muthusamy A; Dor FJMF; Papalois V
    Biomed Res Int; 2019; 2019():7435248. PubMed ID: 30792996
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Favorable outcomes with machine perfusion and longer pump times in kidney transplantation: a single-center, observational study.
    Ciancio G; Gaynor JJ; Sageshima J; Chen L; Roth D; Kupin W; Guerra G; Tueros L; Zarak A; Hanson L; Ganz S; Ruiz P; O'Neill WW; Livingstone AS; Burke GW
    Transplantation; 2010 Oct; 90(8):882-90. PubMed ID: 20703178
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dynamic Parameters of Hypothermic Machine Perfusion-An Image of Initial Graft Function in Adult Kidney Transplantation?
    Weberskirch S; Katou S; Reuter S; Kneifel F; Morgul MH; Becker F; Houben P; Pascher A; Vogel T; Radunz S
    J Clin Med; 2022 Sep; 11(19):. PubMed ID: 36233566
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Delayed graft function has an equally bad impact on deceased donor renal graft survival in both standard criteria donors and expanded criteria donors.
    Hassanain M; Tchervenkov J; Cantarovich M; Metrakos P; Paraskevas S; Keith D; Baran D; Fernandez M; Mangel R; Chaudhury P
    Transplant Proc; 2009; 41(1):133-4. PubMed ID: 19249497
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Major effects of delayed graft function and cold ischaemia time on renal allograft survival.
    Quiroga I; McShane P; Koo DD; Gray D; Friend PJ; Fuggle S; Darby C
    Nephrol Dial Transplant; 2006 Jun; 21(6):1689-96. PubMed ID: 16490743
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Perfusion Parameters of Donation After Cardiac Death Kidneys Predict Early Transplant Outcomes Based on Expanded Criteria Donor Designation.
    Tai Q; Xue W; Ding X; Tian P; Xiang H; Feng X; Yan H; Hou J
    Transplant Proc; 2018; 50(1):79-84. PubMed ID: 29407336
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Time of Cold Storage Prior to Start of Hypothermic Machine Perfusion and Its Influence on Graft Survival.
    Wszola M; Domagala P; Ostaszewska A; Gorski L; Karpeta E; Berman A; Sobol M; Durlik M; Chmura A; Kwiatkowski A
    Transplant Proc; 2019 Oct; 51(8):2514-2519. PubMed ID: 31473005
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Machine perfusion: initial results in an expanded criteria donor kidney transplant program.
    Burgos Revilla FJ; Hevia V; Diez V; Carracedo D; Gomis A; Orosa A; Alvarez S; Gomez V
    Transplant Proc; 2015; 47(1):19-22. PubMed ID: 25645760
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of early graft function on 10-year graft survival in recipients of kidneys from standard- or expanded-criteria donors.
    Smail N; Tchervenkov J; Paraskevas S; Baran D; Mucsi I; Hassanain M; Chaudhury P; Cantarovich M
    Transplantation; 2013 Jul; 96(2):176-81. PubMed ID: 23765113
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Renal transplantation with expanded criteria donors: the experience of one Portuguese center.
    Ferrer F; Mota A; Alves R; Bastos C; Macário F; Figueiredo A; Santos L; Roseiro A; Parada B; Pratas J; Nunes P; Campos M
    Transplant Proc; 2009 Apr; 41(3):791-3. PubMed ID: 19376353
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hypothermic machine perfusion can safely prolong cold ischemia time in deceased donor kidney transplantation. A retrospective analysis on postoperative morbidity and graft function.
    Adani GL; Pravisani R; Tulissi P; Isola M; Calini G; Terrosu G; Boscutti G; Avital I; Ekser B; Baccarani U
    Artif Organs; 2021 May; 45(5):516-523. PubMed ID: 33210745
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.