These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 23635252)

  • 1. A two-dimensional matrix correction for off-axis portal dose prediction errors.
    Bailey DW; Kumaraswamy L; Bakhtiari M; Podgorsak MB
    Med Phys; 2013 May; 40(5):051704. PubMed ID: 23635252
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between an in-house 1D profile correction method and a 2D correction provided in Varian's PDPC Package for improving the accuracy of portal dosimetry images.
    Hobson MA; Davis SD
    J Appl Clin Med Phys; 2015 Mar; 16(2):4973. PubMed ID: 26103173
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A portal dosimetry dose prediction method based on collapsed cone algorithm using the clinical beam model.
    Martínez Ortega J; Gómez González N; Castro Tejero P; Pinto Monedero M; Tolani NB; Núñez Martín L; Sánchez Montero R
    Med Phys; 2017 Jan; 44(1):333-341. PubMed ID: 28102946
    [TBL] [Abstract][Full Text] [Related]  

  • 4. SU-E-T-156: Robust Algorithms for Correction of Predicted Electronic Portal Imager Response.
    Bailey D; Kumaraswamy L; Podgorsak M
    Med Phys; 2012 Jun; 39(6Part12):3739. PubMed ID: 28517832
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry.
    Greer PB
    Med Phys; 2005 Dec; 32(12):3558-68. PubMed ID: 16475754
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An effective correction algorithm for off-axis portal dosimetry errors.
    Bailey DW; Kumaraswamy L; Podgorsak MB
    Med Phys; 2009 Sep; 36(9):4089-94. PubMed ID: 19810481
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device.
    Greer PB
    Med Phys; 2007 Oct; 34(10):3815-24. PubMed ID: 17985627
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A field size specific backscatter correction algorithm for accurate EPID dosimetry.
    Berry SL; Polvorosa CS; Wuu CS
    Med Phys; 2010 Jun; 37(6):2425-34. PubMed ID: 20632552
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm.
    Berry SL; Sheu RD; Polvorosa CS; Wuu CS
    Med Phys; 2012 Jan; 39(1):87-98. PubMed ID: 22225278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams.
    Vial P; Greer PB; Hunt P; Oliver L; Baldock C
    Med Phys; 2008 Apr; 35(4):1267-77. PubMed ID: 18491519
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification.
    Warkentin B; Rathee S; Steciw S
    Med Phys; 2012 Nov; 39(11):6597-608. PubMed ID: 23127054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An energy fluence-convolution model for amorphous silicon EPID dose prediction.
    Greer PB; Cadman P; Lee C; Bzdusek K
    Med Phys; 2009 Feb; 36(2):547-55. PubMed ID: 19291994
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prediction of DVH parameter changes due to setup errors for breast cancer treatment based on 2D portal dosimetry.
    Nijsten SM; van Elmpt WJ; Mijnheer BJ; Minken AW; Persoon LC; Lambin P; Dekker AL
    Med Phys; 2009 Jan; 36(1):83-94. PubMed ID: 19235376
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry.
    Chen J; Chuang CF; Morin O; Aubin M; Pouliot J
    Med Phys; 2006 Mar; 33(3):584-94. PubMed ID: 16878562
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pretreatment verification of IMRT absolute dose distributions using a commercial a-Si EPID.
    Talamonti C; Casati M; Bucciolini M
    Med Phys; 2006 Nov; 33(11):4367-78. PubMed ID: 17153415
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comprehensive fluence model for absolute portal dose image prediction.
    Chytyk K; McCurdy BM
    Med Phys; 2009 Apr; 36(4):1389-98. PubMed ID: 19472646
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A global calibration model for a-Si EPIDs used for transit dosimetry.
    Nijsten SM; van Elmpt WJ; Jacobs M; Mijnheer BJ; Dekker AL; Lambin P; Minken AW
    Med Phys; 2007 Oct; 34(10):3872-84. PubMed ID: 17985633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fast transit portal dosimetry using density-scaled layer modeling of aSi-based electronic portal imaging device and Monte Carlo method.
    Jung JW; Kim JO; Yeo IJ; Cho YB; Kim SM; DiBiase S
    Med Phys; 2012 Dec; 39(12):7593-602. PubMed ID: 23231307
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.
    Greer PB; Vial P; Oliver L; Baldock C
    Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device.
    King BW; Morf D; Greer PB
    Med Phys; 2012 May; 39(5):2839-47. PubMed ID: 22559656
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.