These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 23640001)

  • 1. Design and development of a novel intra-vaginal pressure sensor.
    Kruger J; Hayward L; Nielsen P; Loiselle D; Kirton R
    Int Urogynecol J; 2013 Oct; 24(10):1715-21. PubMed ID: 23640001
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and testing of a vaginal pressure sensor to measure intra-abdominal pressure in women.
    Rosenbluth EM; Johnson PJ; Hitchcock RW; Nygaard IE
    Neurourol Urodyn; 2010 Apr; 29(4):532-5. PubMed ID: 19693948
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of a high-fidelity wireless intravaginal pressure sensor.
    Arora AS; Kruger JA; Budgett DM; Hayward LM; Smalldridge J; Nielsen PF; Kirton RS
    Int Urogynecol J; 2015 Feb; 26(2):243-9. PubMed ID: 25224148
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.
    Coleman TJ; Thomsen JC; Maass SD; Hsu Y; Nygaard IE; Hitchcock RW
    Biomed Microdevices; 2012 Apr; 14(2):347-55. PubMed ID: 22147020
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Should women with incontinence and prolapse do abdominal curls?
    Simpson S; Deeble M; Thompson J; Andrews A; Briffa K
    Int Urogynecol J; 2016 Oct; 27(10):1507-12. PubMed ID: 27037561
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fiber-optic sensor-based device for the measurement of vaginal integrity in women.
    Parkinson LA; Rosamilia A; Mukherjee S; Papageorgiou AW; Melendez-Munoz J; Werkmeister JA; Gargett CE; Arkwright JW
    Neurourol Urodyn; 2019 Nov; 38(8):2264-2272. PubMed ID: 31385355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reproducibility of intra-abdominal pressure measured during physical activities via a wireless vaginal transducer.
    Egger MJ; Hamad NM; Hitchcock RW; Coleman TJ; Shaw JM; Hsu Y; Nygaard IE
    Female Pelvic Med Reconstr Surg; 2015; 21(3):164-9. PubMed ID: 25730430
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intra-abdominal pressure during Pilates: unlikely to cause pelvic floor harm.
    Coleman TJ; Nygaard IE; Holder DN; Egger MJ; Hitchcock R
    Int Urogynecol J; 2015 Aug; 26(8):1123-30. PubMed ID: 25672647
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a novel intra-vaginal transducer with improved dynamic response.
    Johnson PJ; Rosenbluth EM; Nygaard IE; Parikh MK; Hitchcock RW
    Biomed Microdevices; 2009 Dec; 11(6):1213-21. PubMed ID: 19629699
    [TBL] [Abstract][Full Text] [Related]  

  • 10. More complicated than it looks: the vagaries of calculating intra-abdominal pressure.
    Hamad NM; Shaw JM; Nygaard IE; Coleman TJ; Hsu Y; Egger M; Hitchcock RW
    J Strength Cond Res; 2013 Nov; 27(11):3204-15. PubMed ID: 23439349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intra-abdominal Pressure and Pelvic Floor Health: Should We Be Thinking About This Relationship Differently?
    Dietze-Hermosa M; Hitchcock R; Nygaard IE; Shaw JM
    Female Pelvic Med Reconstr Surg; 2020 Jul; 26(7):409-414. PubMed ID: 32574030
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-dimensional finite element analysis of the pelvic organ prolapse: A parametric biomechanical modeling.
    Babayi M; Azghani MR; Hajebrahimi S; Berghmans B
    Neurourol Urodyn; 2019 Feb; 38(2):591-598. PubMed ID: 30499117
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Are pelvic floor muscle thickness and size of levator hiatus associated with pelvic floor muscle strength, endurance and vaginal resting pressure in women with pelvic organ prolapse stages I-III? A cross sectional 3D ultrasound study.
    Braekken IH; Majida M; Engh ME; Bø K
    Neurourol Urodyn; 2014 Jan; 33(1):115-20. PubMed ID: 23444289
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical evaluation of a wireless intra-vaginal pressure transducer.
    Hsu Y; Coleman TJ; Hitchcock RW; Heintz K; Shaw JM; Nygaard IE
    Int Urogynecol J; 2012 Dec; 23(12):1741-7. PubMed ID: 22618208
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Symptoms of pelvic organ prolapse in women who lift heavy weights for exercise: a cross-sectional survey.
    Forner LB; Beckman EM; Smith MD
    Int Urogynecol J; 2020 Aug; 31(8):1551-1558. PubMed ID: 31813038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Muscle strength measurement of pelvic floor in women by vaginal dynamometer].
    Parezanović-Ilić K; Jevtić M; Jeremić B; Arsenijević S
    Srp Arh Celok Lek; 2009; 137(9-10):511-7. PubMed ID: 19950758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Physical activity and pelvic floor muscle training in patients with pelvic organ prolapse: a pilot study.
    Ouchi M; Kato K; Gotoh M; Suzuki S
    Int Urogynecol J; 2017 Dec; 28(12):1807-1815. PubMed ID: 28624919
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Influence of Early Exercise Postpartum on Pelvic Floor Muscle Function and Prevalence of Pelvic Floor Dysfunction 12 Months Postpartum.
    Tennfjord MK; Engh ME; Bø K
    Phys Ther; 2020 Aug; 100(9):1681-1689. PubMed ID: 32367136
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Method of limits: Female genital stretch perception thresholds.
    Mahoney C; Chok SM; Bryant A; Myers J; Smith A; Reid F
    Neurourol Urodyn; 2020 Feb; 39(2):778-784. PubMed ID: 31961957
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contractile response of human anterior vaginal muscularis in women with and without pelvic organ prolapse.
    Northington GM; Basha M; Arya LA; Wein AJ; Chacko S
    Reprod Sci; 2011 Mar; 18(3):296-303. PubMed ID: 21193802
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.