These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 23647572)
1. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation. Khir AW; Bruti G Artif Organs; 2013 Jul; 37(7):E88-95. PubMed ID: 23647572 [TBL] [Abstract][Full Text] [Related]
2. Measurements of Intra-Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation. Bruti G; Kolyva C; Pepper JR; Khir AW Artif Organs; 2015 Aug; 39(8):E154-63. PubMed ID: 25959284 [TBL] [Abstract][Full Text] [Related]
3. Pressure and flow-volume distribution associated with intra-aortic balloon inflation: an in vitro study. Biglino G; Whitehorne M; Pepper JR; Khir AW Artif Organs; 2008 Jan; 32(1):19-27. PubMed ID: 18181799 [TBL] [Abstract][Full Text] [Related]
4. Pressure-wave energy relationship during IABP counterpulsation in a mock circulation: changes with angle and assisting frequency. Biglino G; Kolyva C; Khir AW Int J Artif Organs; 2012 Jan; 35(1):15-24. PubMed ID: 22287201 [TBL] [Abstract][Full Text] [Related]
5. Variations in aortic pressure affect the mechanics of the intra-aortic balloon: an in vitro investigation. Biglino G; Kolyva C; Whitehorne M; Pepper JR; Khir AW Artif Organs; 2010 Jul; 34(7):546-53. PubMed ID: 20528852 [TBL] [Abstract][Full Text] [Related]
6. Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis. Lu PJ; Yang CF; Wu MY; Hung CH; Chan MY; Hsu TC J Thorac Cardiovasc Surg; 2011 Nov; 142(5):1205-13. PubMed ID: 21477820 [TBL] [Abstract][Full Text] [Related]
7. A mock circulatory system with physiological distribution of terminal resistance and compliance: application for testing the intra-aortic balloon pump. Kolyva C; Biglino G; Pepper JR; Khir AW Artif Organs; 2012 Mar; 36(3):E62-70. PubMed ID: 21039645 [TBL] [Abstract][Full Text] [Related]
8. Newly Shaped Intra-Aortic Balloons Improve the Performance of Counterpulsation at the Semirecumbent Position: An In Vitro Study. Kolyva C; Pepper JR; Khir AW Artif Organs; 2016 Aug; 40(8):E146-57. PubMed ID: 27530674 [TBL] [Abstract][Full Text] [Related]
9. How much of the intraaortic balloon volume is displaced toward the coronary circulation? Kolyva C; Pantalos GM; Pepper JR; Khir AW J Thorac Cardiovasc Surg; 2010 Jul; 140(1):110-6. PubMed ID: 20080266 [TBL] [Abstract][Full Text] [Related]
11. The use of a small intra-aortic balloon to increase coronary flow. Antonatos PG; Anthopoulos LP; Vrettos AN; Moulopoulos SD Life Support Syst; 1983; 1(3):151-64. PubMed ID: 6679013 [TBL] [Abstract][Full Text] [Related]
12. Effects of intra-aortic balloon pump timing on baroreflex activities in a closed-loop cardiovascular hybrid model. Fresiello L; Khir AW; Di Molfetta A; Kozarski M; Ferrari G Artif Organs; 2013 Mar; 37(3):237-47. PubMed ID: 23121229 [TBL] [Abstract][Full Text] [Related]
13. Impact of intraaortic balloon counterpulsation on arterial blood flow in juvenile pigs with heart failure. Fischi MC; Tondato F; Adams R; Cui J; Hutchison M; Chronos NA J Invasive Cardiol; 2004 Apr; 16(4):181-3. PubMed ID: 15152141 [TBL] [Abstract][Full Text] [Related]
15. Comparison of an extraaortic counterpulsation device versus intraaortic balloon pumping in severe cardiac failure. Zelano JA; Ko W; Lazzaro R; Lazenby WD; Topaz S; Kolff WJ; Isom OW; Krieger KH ASAIO Trans; 1991; 37(3):M342-4. PubMed ID: 1751178 [TBL] [Abstract][Full Text] [Related]
16. Hemodynamic simulation study of a novel intra-aorta left ventricular assist device. Xuan Y; Chang Y; Gu K; Gao B ASAIO J; 2012; 58(5):462-9. PubMed ID: 22929899 [TBL] [Abstract][Full Text] [Related]
17. A novel coronary active perfusion system using a conventional intra-aortic balloon pump for off-pump coronary artery bypass grafting. Kiuchi R; Tomita S; Yamaguchi S; Nishida Y; Ohtake H; Nakamura H; Watanabe G J Thorac Cardiovasc Surg; 2014 Jul; 148(1):304-10. PubMed ID: 24472314 [TBL] [Abstract][Full Text] [Related]
18. Intra-aortic balloon pumping: does posture matter? Khir AW; Price S; Hale C; Young DA; Parker KH; Pepper JR Artif Organs; 2005 Jan; 29(1):36-40. PubMed ID: 15644081 [TBL] [Abstract][Full Text] [Related]
19. The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system. Gao B; Chang Y; Xuan Y; Zeng Y; Liu Y Artif Organs; 2013 Feb; 37(2):157-65. PubMed ID: 23379287 [TBL] [Abstract][Full Text] [Related]