These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

234 related articles for article (PubMed ID: 23649068)

  • 21. Resin-based pit-and-fissure sealants: microleakage reduction and infiltration enhancement using a bonding agent.
    Meller C; Reichenmiller K; Schwahn C; Samietz S; Blunck U
    J Adhes Dent; 2015 Feb; 17(1):59-65. PubMed ID: 25625135
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of bonding agents on the microleakage of sealant following contamination with saliva.
    Askarizadeh N; Norouzi N; Nemati S
    J Indian Soc Pedod Prev Dent; 2008 Jun; 26(2):64-6. PubMed ID: 18603730
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of adhesive agent and fissure morphology on the in vitro microleakage and penetrability of pit and fissure sealants.
    Marks D; Owens BM; Johnson WW
    Quintessence Int; 2009 Oct; 40(9):763-72. PubMed ID: 19862403
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Microleakage under lingual retainer composite bonded with an antibacterial monomer-containing adhesive system.
    Uysal T; Ulker M; Baysal A; Usumez S
    World J Orthod; 2009; 10(3):196-201. PubMed ID: 19885420
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effect of fissure morphology and pretreatment of the enamel surface on penetration and adhesion of fissure sealants.
    Symons AL; Chu CY; Meyers IA
    J Oral Rehabil; 1996 Dec; 23(12):791-8. PubMed ID: 8971640
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Er,Cr:YSGG laser pretreatment of primary teeth for bonded fissure sealant application: a quantitative microleakage study.
    Cehreli SB; Gungor HC; Karabulut E
    J Adhes Dent; 2006 Dec; 8(6):381-6. PubMed ID: 17243595
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In Vitro Evaluation of Different Protocols for Preventing Microleakage of Fissure Sealants Placed Following Saliva Contamination.
    Şimşek H; Yazıcı AR; Güngör HC
    J Clin Pediatr Dent; 2020 Aug; 44(4):240-248. PubMed ID: 33167017
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessing microleakage in resin composite restorations rebonded with a surface sealant and three low-viscosity resin systems.
    Ramos RP; Chinelatti MA; Chimello DT; Dibb RG
    Quintessence Int; 2002 Jun; 33(6):450-6. PubMed ID: 12073726
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Microleakage of three sealants following conventional, bur, and air-abrasion preparation of pits and fissures.
    Hatibovic-Kofman S; Butler SA; Sadek H
    Int J Paediatr Dent; 2001 Nov; 11(6):409-16. PubMed ID: 11759100
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Bond strength of a sealant to permanent enamel: evaluation of 3 application protocols.
    Asselin ME; Sitbon Y; Fortin D; Abelardo L; Rompre PH
    Pediatr Dent; 2009; 31(4):323-8. PubMed ID: 19722442
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Length of resin tags in pit-and-fissure sealants: all-in-one self-etching adhesive vs phosphoric acid etching.
    dos Santos KT; Sundfeld RH; Garbin CA; de Alexandre RS; Sundefeld ML; Ceolim BN
    Compend Contin Educ Dent; 2008 Apr; 29(3):186-92. PubMed ID: 18468305
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Marginal seal of sealant and compomer materials with and without enameloplasty.
    Salama FS; Al-Hammad NS
    Int J Paediatr Dent; 2002 Jan; 12(1):39-46. PubMed ID: 11853247
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Degree of microleakage of a self-etch sealant.
    Conner FA; Vandewalle KS; Bartoloni JA
    Gen Dent; 2011; 59(3):224-8. PubMed ID: 21903546
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Influence of self-etch all-in-one adhesives on fissure sealant shear bond strength under contaminated enamel conditions.
    Coelho A; Canta JP; Martins JNR; Arantes-Oliveira S; Marques PF
    Eur Arch Paediatr Dent; 2019 Feb; 20(1):15-22. PubMed ID: 30328065
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of mechanical and thermal aging on microleakage of different fissure sealants.
    Koyuturk AE; Kusgoz A; Ulker M; Yeşilyurt C
    Dent Mater J; 2008 Nov; 27(6):795-801. PubMed ID: 19241687
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of bonding agents on the microleakage and bond strength of sealant in primary teeth.
    Tulunoğlu O; Bodur H; Uçtaşli M; Alaçam A
    J Oral Rehabil; 1999 May; 26(5):436-41. PubMed ID: 10373092
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Microleakage and penetration ability of resin sealant versus bonding system when applied following contamination.
    Duangthip D; Lussi A
    Pediatr Dent; 2003; 25(5):505-11. PubMed ID: 14649617
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of new generation surface sealants on the marginal permeability of Class V resin composite restorations.
    Owens BM; Johnson WW
    Oper Dent; 2006; 31(4):481-8. PubMed ID: 16924989
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Bond strength of a sealant to primary and permanent enamel: phosphoric acid versus self-etching adhesive.
    Peutzfeldt A; Nielsen LA
    Pediatr Dent; 2004; 26(3):240-4. PubMed ID: 15185805
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of composite resin placement techniques on the microleakage of two self-etching dentin-bonding agents.
    Santini A; Plasschaert AJ; Mitchell S
    Am J Dent; 2001 Jun; 14(3):132-6. PubMed ID: 11572288
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.