These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 23649278)

  • 1. Accuracy of torque-limiting devices for mini-implant removal: an in vitro study.
    Pauls A; Nienkemper M; Drescher D
    J Orofac Orthop; 2013 May; 74(3):205-16. PubMed ID: 23649278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.
    Pauls A; Nienkemper M; Drescher D
    J Orofac Orthop; 2013 Mar; 74(2):124-36. PubMed ID: 23467731
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Placement and removal torque values of orthodontic miniscrew implants.
    Suzuki EY; Suzuki B
    Am J Orthod Dentofacial Orthop; 2011 May; 139(5):669-78. PubMed ID: 21536211
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental investigation of the fracture torque of orthodontic anchorage screws.
    Reimann S; Ayubi M; McDonald F; Bourauel C
    J Orofac Orthop; 2016 Jul; 77(4):272-80. PubMed ID: 27098641
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical properties of orthodontic miniscrews. An in-vitro study.
    Florvaag B; Kneuertz P; Lazar F; Koebke J; Zöller JE; Braumann B; Mischkowski RA
    J Orofac Orthop; 2010 Jan; 71(1):53-67. PubMed ID: 20135250
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study.
    Tepedino M; Masedu F; Chimenti C
    Head Face Med; 2017 May; 13(1):10. PubMed ID: 28558821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Insertion torque and success of orthodontic mini-implants: a systematic review.
    Meursinge Reynders RA; Ronchi L; Ladu L; van Etten-Jamaludin F; Bipat S
    Am J Orthod Dentofacial Orthop; 2012 Nov; 142(5):596-614.e5. PubMed ID: 23116501
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microcomputed tomographic analysis of bone reaction at insertion of orthodontic mini-implants in sheep.
    Rebaudi A; Laffi N; Benedicenti S; Angiero F; Romanos GE
    Int J Oral Maxillofac Implants; 2011; 26(6):1233-40. PubMed ID: 22167428
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Convenient removal of orthodontic mini-implants.
    Kim H; Kim TK; Lee SJ
    Am J Orthod Dentofacial Orthop; 2007 Apr; 131(4 Suppl):S90-1. PubMed ID: 17448392
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of insertion method and postinsertion time interval prior to force application on the removal torque of orthodontic miniscrews.
    Sharifi M; Ghassemi A; Bayani S
    Int J Oral Maxillofac Implants; 2015; 30(1):35-40. PubMed ID: 25506646
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study.
    Wilmes B; Panayotidis A; Drescher D
    Eur J Orthod; 2011 Aug; 33(4):396-401. PubMed ID: 21310766
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Removal torque of miniscrews used for orthodontic anchorage--a preliminary report.
    Chen YJ; Chen YH; Lin LD; Yao CC
    Int J Oral Maxillofac Implants; 2006; 21(2):283-9. PubMed ID: 16634500
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Insertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.
    Hosein YK; Smith A; Dunning CE; Tassi A
    Int J Oral Maxillofac Implants; 2016; 31(3):e57-64. PubMed ID: 27183083
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Removal torque values of surface-treated mini-implants after loading.
    Kim SH; Cho JH; Chung KR; Kook YA; Nelson G
    Am J Orthod Dentofacial Orthop; 2008 Jul; 134(1):36-43. PubMed ID: 18617101
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the Effect of Platelet-Released Growth Factor and Immediate Orthodontic Loading on the Removal Torque of Miniscrews.
    Bayani S; Masoomi F; Aghaabbasi S; Farsinejad A
    Int J Oral Maxillofac Implants; 2016; 31(2):471-7. PubMed ID: 27004294
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peak insertion torque values of five mini-implant systems under different insertion loads.
    Quraishi E; Sherriff M; Bister D
    J Orthod; 2014 Jun; 41(2):102-9. PubMed ID: 24521745
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the fracture torque of different Brazilian mini-implants.
    Lima GM; Soares MS; Penha SS; Romano MM
    Braz Oral Res; 2011; 25(2):116-21. PubMed ID: 21537637
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Removal torque of osseointegrated mini-implants: an in vivo evaluation.
    Favero LG; Pisoni A; Paganelli C
    Eur J Orthod; 2007 Oct; 29(5):443-8. PubMed ID: 17974534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of miniscrew taper morphology on insertion and removal torque in dogs.
    Cha JY; Takano-Yamamoto T; Hwang CJ
    Int J Oral Maxillofac Implants; 2010; 25(4):777-83. PubMed ID: 20657874
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of mechanical torque-limiting gauges for mini-screw placement.
    Schätzle M; Golland D; Roos M; Stawarczyk B
    Clin Oral Implants Res; 2010 Aug; 21(8):781-8. PubMed ID: 20465553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.