BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 236531)

  • 21. An improved sensor and a method for transcutaneous CO2 monitoring.
    Beran AV; Shigezawa GY; Yeung HN; Huxtable RF
    Acta Anaesthesiol Scand Suppl; 1978; 68():111-7. PubMed ID: 279192
    [No Abstract]   [Full Text] [Related]  

  • 22. [Analytical reliability of the results of a pH and blood gas study using automatic analyzers].
    Dimitrova S; Tsachev K; Dochev D; Kuzmov I
    Vutr Boles; 1984; 23(4):91-9. PubMed ID: 6506665
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of syringe material and temperature and duration of storage on the stability of equine arterial blood gas variables.
    Deane JC; Dagleish MP; Benamou AE; Wolf BT; Marlin D
    Vet Anaesth Analg; 2004 Oct; 31(4):250-7. PubMed ID: 15509289
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Simultaneous measurement of blood concentrations of O2 and CO with a Van Slyke apparatus].
    Haag JR; Tempini A; Tschopp M; Haab P
    J Physiol (Paris); 1982-1983; 78(9):843-7. PubMed ID: 7187771
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A simplified breath-holding method for measuring oxygenated mixed venous carbon dioxide pressure.
    Hoffstein V; Rebuck AS
    J Lab Clin Med; 1981 Sep; 98(3):437-43. PubMed ID: 6790645
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reliability of blood PCO2 measurements by the CO2-electrode, the whole-blood CCO2-pH method and the Astrup method.
    Bärtschi F; Held DR; Haab P
    Respir Physiol; 1970 Jul; 10(1):121-31. PubMed ID: 5430144
    [No Abstract]   [Full Text] [Related]  

  • 27. Automated noninvasive determination of mixed venous pCO2.
    Leavell K; Finkelstein SM; Warwick WJ; Budd JR
    Med Instrum; 1986; 20(5):248-54. PubMed ID: 3097463
    [TBL] [Abstract][Full Text] [Related]  

  • 28. PCO2-optode, fluorescence fotometric device to measure the transcutaneous PCO2.
    Lübbers DW; Hannebauer F; Opitz N
    Birth Defects Orig Artic Ser; 1979; 15(4):123-6. PubMed ID: 534691
    [No Abstract]   [Full Text] [Related]  

  • 29. [Effect of heparin on the result of pH and blood gas measurements. Study at 2 PCO2 and PO2 levels].
    Joly JB; Faussat AM; Chevrie J
    Pediatrie; 1973; 28(3):283-9. PubMed ID: 4726385
    [No Abstract]   [Full Text] [Related]  

  • 30. A method of measuring continuously in-vivo blood pCO2, pO2 and pH in the intact animal.
    Sugioka K
    Biomed Sci Instrum; 1968; 4():185-9. PubMed ID: 5638839
    [No Abstract]   [Full Text] [Related]  

  • 31. Saline PCO2 is an important source of error in the assessment of gastric intramucosal pH.
    Takala J; Parviainen I; Siloaho M; Ruokonen E; Hämäläinen E
    Crit Care Med; 1994 Nov; 22(11):1877-9. PubMed ID: 7956295
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An evaluation of the Harleco total carbon dioxide apparatus.
    Creno RJ; Farrand J; Koch BH
    Am J Med Technol; 1974 Feb; 40(2):50-4. PubMed ID: 4813468
    [No Abstract]   [Full Text] [Related]  

  • 33. Syringe injection pressure: a neglected factor in blood PO2 determination.
    Gosling P; Dickson G
    Ann Clin Biochem; 1990 Mar; 27 ( Pt 2)():147-51. PubMed ID: 2109568
    [TBL] [Abstract][Full Text] [Related]  

  • 34. History of blood gas analysis. III. Carbon dioxide tension.
    Severinghaus JW; Astrup PB
    J Clin Monit; 1986 Jan; 2(1):60-73. PubMed ID: 3086509
    [TBL] [Abstract][Full Text] [Related]  

  • 35. On calculating concentrations of "HCO3" from pH and PCO2.
    Burton RF
    Comp Biochem Physiol A Comp Physiol; 1987; 87(2):417-22. PubMed ID: 2886282
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Potentiometric determination of carbon dioxide partial pressure and pH in ultramicro volumes of biological fluids.
    Pita JC
    Anal Chem; 1969 Feb; 41(2):273-8. PubMed ID: 5377349
    [No Abstract]   [Full Text] [Related]  

  • 37. Indirect determination of mean whole body and intracellular CO2 and buffer capacity.
    Albers C; Ludwig O; Usinger W; Spaich P
    Respir Physiol; 1971 Jan; 11(2):197-210. PubMed ID: 5540206
    [No Abstract]   [Full Text] [Related]  

  • 38. A modified Van Slyke apparatus.
    Brix O
    J Appl Physiol Respir Environ Exerc Physiol; 1981 May; 50(5):1093-7. PubMed ID: 7228760
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Osmometry of CO2 in gas samples.
    Oh MS; Kee CS; Uribarri J; Carroll HJ
    Clin Chem; 1983 May; 29(5):884-6. PubMed ID: 6404569
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Measurement of total CO
    Trepiccione F; Iena FM; Catalini L; Carpi FM; Koed M; Frische S
    Pflugers Arch; 2017 Oct; 469(10):1267-1275. PubMed ID: 28585052
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.