BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

616 related articles for article (PubMed ID: 23657551)

  • 1. Transcatheter aortic valve implantation using anatomically oriented, marrow stromal cell-based, stented, tissue-engineered heart valves: technical considerations and implications for translational cell-based heart valve concepts.
    Emmert MY; Weber B; Behr L; Sammut S; Frauenfelder T; Wolint P; Scherman J; Bettex D; Grünenfelder J; Falk V; Hoerstrup SP
    Eur J Cardiothorac Surg; 2014 Jan; 45(1):61-8. PubMed ID: 23657551
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stem cell-based transcatheter aortic valve implantation: first experiences in a pre-clinical model.
    Emmert MY; Weber B; Wolint P; Behr L; Sammut S; Frauenfelder T; Frese L; Scherman J; Brokopp CE; Templin C; Grünenfelder J; Zünd G; Falk V; Hoerstrup SP
    JACC Cardiovasc Interv; 2012 Aug; 5(8):874-83. PubMed ID: 22917460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Injectable living marrow stromal cell-based autologous tissue engineered heart valves: first experiences with a one-step intervention in primates.
    Weber B; Scherman J; Emmert MY; Gruenenfelder J; Verbeek R; Bracher M; Black M; Kortsmit J; Franz T; Schoenauer R; Baumgartner L; Brokopp C; Agarkova I; Wolint P; Zund G; Falk V; Zilla P; Hoerstrup SP
    Eur Heart J; 2011 Nov; 32(22):2830-40. PubMed ID: 21415068
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimally-invasive implantation of living tissue engineered heart valves: a comprehensive approach from autologous vascular cells to stem cells.
    Schmidt D; Dijkman PE; Driessen-Mol A; Stenger R; Mariani C; Puolakka A; Rissanen M; Deichmann T; Odermatt B; Weber B; Emmert MY; Zund G; Baaijens FP; Hoerstrup SP
    J Am Coll Cardiol; 2010 Aug; 56(6):510-20. PubMed ID: 20670763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transapical implantation of a second-generation transcatheter heart valve in patients with noncalcified aortic regurgitation.
    Seiffert M; Diemert P; Koschyk D; Schirmer J; Conradi L; Schnabel R; Blankenberg S; Reichenspurner H; Baldus S; Treede H
    JACC Cardiovasc Interv; 2013 Jun; 6(6):590-7. PubMed ID: 23683735
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Off-pump transapical mitral valve-in-ring implantation.
    Zou Y; Ferrari E; von Segesser LK
    Eur J Cardiothorac Surg; 2013 Apr; 43(4):849-55. PubMed ID: 22822106
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study.
    Treede H; Mohr FW; Baldus S; Rastan A; Ensminger S; Arnold M; Kempfert J; Figulla HR
    Eur J Cardiothorac Surg; 2012 Jun; 41(6):e131-8. PubMed ID: 22508111
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Trans-apical versus surgical implantation of autologous ovine tissue-engineered heart valves.
    Dijkman PE; Driessen-Mol A; de Heer LM; Kluin J; van Herwerden LA; Odermatt B; Baaijens FP; Hoerstrup SP
    J Heart Valve Dis; 2012 Sep; 21(5):670-8. PubMed ID: 23167234
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transapical implantation of a self-expandable aortic valve prosthesis utilizing a novel designed positioning element.
    Liu X; Tang Y; Luo F; Tian Y; Li K; Sun J; Jia L; Wang W
    Catheter Cardiovasc Interv; 2017 Jan; 89(1):E30-E37. PubMed ID: 26811261
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of the Engager™ aortic transcatheter valve system using a flexible over-the-wire design.
    Sündermann SH; Grünenfelder J; Corti R; Rastan AJ; Linke A; Lange R; Falk V; Bleiziffer S
    Eur J Cardiothorac Surg; 2012 Oct; 42(4):e48-52. PubMed ID: 22743081
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new self-expandable transcatheter aortic valve for transapical implantation: feasibility in acute and chronic animal experiments.
    Wendt D; Pasa S; Kahlert P; Delaloye S; Al-Rashid F; Price V; Jánosi RA; Borenstein N; Behr L; Konorza T; Erbel R; Jakob H; Thielmann M
    Scand Cardiovasc J; 2013 Jun; 47(3):145-53. PubMed ID: 23098267
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental evaluation of the JenaClip transcatheter aortic valve.
    Lauten A; Ferrari M; Petri A; Ensminger SM; Gummert JF; Boudjemline Y; Schubert H; Schumm J; Hekmat K; Schlosser M; Figulla HR
    Catheter Cardiovasc Interv; 2009 Sep; 74(3):514-9. PubMed ID: 19434747
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Transapical approach for aortic stented valve implantation: experimental results].
    Flecher EM; Joudinaud TM; Curry JW; Solis J; Lopez J; Kegel C; Weber P; Duran C
    Ann Cardiol Angeiol (Paris); 2007 Jun; 56(3):122-5. PubMed ID: 17524346
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter implantation of homologous "off-the-shelf" tissue-engineered heart valves with self-repair capacity: long-term functionality and rapid in vivo remodeling in sheep.
    Driessen-Mol A; Emmert MY; Dijkman PE; Frese L; Sanders B; Weber B; Cesarovic N; Sidler M; Leenders J; Jenni R; Grünenfelder J; Falk V; Baaijens FPT; Hoerstrup SP
    J Am Coll Cardiol; 2014 Apr; 63(13):1320-1329. PubMed ID: 24361320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transapical implantation of a novel self-expanding sutureless aortic valve prosthesis.
    Stalder M; Suri RM; Kraehenbuehl ES; Hellige G; Wenaweser P; Zobrist C; Schaff HV; Carrel TP
    J Heart Valve Dis; 2010 Mar; 19(2):182-7; discussion 188. PubMed ID: 20369501
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcome of patients treated with Engager transapical aortic valve implantation: one-year results of the feasibility study.
    Sündermann SH; Grünenfelder J; Corti R; Rastan AJ; Linke A; Lange R; Falk V; Bleiziffer S
    Innovations (Phila); 2013; 8(5):332-6. PubMed ID: 24346580
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transapical aortic valve implantation: an animal feasibility study.
    Dewey TM; Walther T; Doss M; Brown D; Ryan WH; Svensson L; Mihaljevic T; Hambrecht R; Schuler G; Wimmer-Greinecker G; Mohr FW; Mack MJ
    Ann Thorac Surg; 2006 Jul; 82(1):110-6. PubMed ID: 16798200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Initial experience of transcatheter implantation with a new aortic valve in sheep].
    Wang JM; Yang J; Yang LF; Zhang XX; Hu Y; Liu JC; Yu SQ; Yi DH
    Zhonghua Xin Xue Guan Bing Za Zhi; 2011 Nov; 39(11):1005-10. PubMed ID: 22336452
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First percutaneous implantation of a completely tissue-engineered self-expanding pulmonary heart valve prosthesis using a newly developed delivery system: a feasibility study in sheep.
    Spriestersbach H; Prudlo A; Bartosch M; Sanders B; Radtke T; Baaijens FP; Hoerstrup SP; Berger F; Schmitt B
    Cardiovasc Interv Ther; 2017 Jan; 32(1):36-47. PubMed ID: 27139179
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a Novel Human Cell-Derived Tissue-Engineered Heart Valve for Transcatheter Aortic Valve Replacement: an In Vitro and In Vivo Feasibility Study.
    Lintas V; Fioretta ES; Motta SE; Dijkman PE; Pensalfini M; Mazza E; Caliskan E; Rodriguez H; Lipiski M; Sauer M; Cesarovic N; Hoerstrup SP; Emmert MY
    J Cardiovasc Transl Res; 2018 Dec; 11(6):470-482. PubMed ID: 30105605
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.