These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 23659098)

  • 41. The LightSpeed system.
    Barbakow F
    Dent Clin North Am; 2004 Jan; 48(1):113-35. PubMed ID: 15066510
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The new GT Series X rotary shaping system: objectives and technique principles.
    Buchanan LS
    Dent Today; 2008 Jan; 27(1):70, 72, 74 passim. PubMed ID: 18240635
    [No Abstract]   [Full Text] [Related]  

  • 43. A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments.
    Wan J; Rasimick BJ; Musikant BL; Deutsch AS
    Aust Endod J; 2011 Dec; 37(3):122-7. PubMed ID: 22117719
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.
    Kim HC; Lee MH; Yum J; Versluis A; Lee CJ; Kim BM
    J Endod; 2010 Jul; 36(7):1195-9. PubMed ID: 20630298
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Torsional strength and toughness of nickel-titanium rotary files.
    Yum J; Cheung GS; Park JK; Hur B; Kim HC
    J Endod; 2011 Mar; 37(3):382-6. PubMed ID: 21329826
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Ability of chemomechanical preparation with either rotary instruments or self-adjusting file to disinfect oval-shaped root canals.
    Siqueira JF; Alves FR; Almeida BM; de Oliveira JC; Rôças IN
    J Endod; 2010 Nov; 36(11):1860-5. PubMed ID: 20951301
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Reciprocating instruments in endodontics: a review of the literature.
    van der Vyver PJ; Jonker C
    SADJ; 2014 Oct; 69(9):404-9. PubMed ID: 26571923
    [No Abstract]   [Full Text] [Related]  

  • 48. A comparison of the shaping effects of 5 nickel-titanium rotary instruments in simulated S-shaped canals.
    Ersev H; Yilmaz B; Ciftçioğlu E; Ozkarsli SF
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 May; 109(5):e86-93. PubMed ID: 20416526
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Torque during canal instrumentation using rotary nickel-titanium files.
    Sattapan B; Palamara JE; Messer HH
    J Endod; 2000 Mar; 26(3):156-60. PubMed ID: 11199710
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review.
    Gutmann JL; Gao Y
    Int Endod J; 2012 Feb; 45(2):113-28. PubMed ID: 21902705
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals.
    Schäfer E
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2001 Aug; 92(2):215-20. PubMed ID: 11505270
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement.
    Gavini G; Caldeira CL; Akisue E; Candeiro GT; Kawakami DA
    J Endod; 2012 May; 38(5):684-7. PubMed ID: 22515903
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Tips to avoid instrument separation in endodontics.
    Mullane EM
    J Ir Dent Assoc; 2015; 61(4):192-4. PubMed ID: 26506698
    [No Abstract]   [Full Text] [Related]  

  • 54. Comparison of root canal preparation with two rotary NiTi instruments: ProFile .04 and GT Rotary.
    Rödig T; Hülsmann M; Kahlmeier C
    Int Endod J; 2007 Jul; 40(7):553-62. PubMed ID: 17511784
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry.
    Bergmans L; Van Cleynenbreugel J; Wevers M; Lambrechts P
    Am J Dent; 2001 Oct; 14(5):324-33. PubMed ID: 11803999
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Current developments in rotary root canal instrument technology and clinical use: a review.
    Peters OA; Paque F
    Quintessence Int; 2010 Jun; 41(6):479-88. PubMed ID: 20490390
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion.
    Gambarini G; Gergi R; Naaman A; Osta N; Al Sudani D
    Int Endod J; 2012 Sep; 45(9):802-6. PubMed ID: 22429241
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The evolution of instrumentation and obturation leading to a simplified approach.
    Musikant BL; Cohen BI; Deutsch AS
    Compend Contin Educ Dent; 2000 Nov; 21(11):980-6, 988, 990. PubMed ID: 11968149
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Fracture of ProFile nickel-titanium rotary instruments: a laboratory simulation assessment.
    Di Fiore PM; Genov KI; Komaroff E; Dasanayake AP; Lin L
    Int Endod J; 2006 Jun; 39(6):502-9. PubMed ID: 16674746
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.
    Inan U; Aydin C
    J Endod; 2012 Jan; 38(1):108-11. PubMed ID: 22152632
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.