These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 23659912)

  • 41. Biomechanical evaluation of occipitocervicothoracic fusion: impact of partial or sequential fixation.
    Cheng BC; Hafez MA; Cunningham B; Serhan H; Welch WC
    Spine J; 2008; 8(5):821-6. PubMed ID: 17981098
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Biomechanical analysis of rotational motions after disc arthroplasty: implications for patients with adult deformities.
    McAfee PC; Cunningham BW; Hayes V; Sidiqi F; Dabbah M; Sefter JC; Hu N; Beatson H
    Spine (Phila Pa 1976); 2006 Sep; 31(19 Suppl):S152-60. PubMed ID: 16946633
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The instant axis of rotation influences facet forces at L5/S1 during flexion/extension and lateral bending.
    Rousseau MA; Bradford DS; Hadi TM; Pedersen KL; Lotz JC
    Eur Spine J; 2006 Mar; 15(3):299-307. PubMed ID: 16175392
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The influence of fixed sagittal plane centers of rotation on motion segment mechanics and range of motion in the cervical spine.
    Kelly BP; Zufelt NA; Sander EJ; DiAngelo DJ
    J Biomech; 2013 Apr; 46(7):1369-75. PubMed ID: 23499226
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Biomechanical evaluation of a new total posterior-element replacement system.
    Wilke HJ; Schmidt H; Werner K; Schmölz W; Drumm J
    Spine (Phila Pa 1976); 2006 Nov; 31(24):2790-6; discussion 2797. PubMed ID: 17108830
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Biomechanics of the C5-C6 spinal unit before and after placement of a disc prosthesis.
    Galbusera F; Fantigrossi A; Raimondi MT; Sassi M; Fornari M; Assietti R
    Biomech Model Mechanobiol; 2006 Nov; 5(4):253-61. PubMed ID: 16514519
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Cervical segmental motion at levels adjacent to disc herniation as determined with kinetic magnetic resonance imaging.
    Daffner SD; Xin J; Taghavi CE; Hymanson HJ; Mudiyam C; Hongyu W; Wang JC
    Spine (Phila Pa 1976); 2009 Oct; 34(22):2389-94. PubMed ID: 19829252
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Progressive disc degeneration at C5-C6 segment affects the mechanics between disc heights and posterior facets above and below the degenerated segment: A flexion-extension investigation using a poroelastic C3-T1 finite element model.
    Hussain M; Natarajan RN; An HS; Andersson GB
    Med Eng Phys; 2012 Jun; 34(5):552-8. PubMed ID: 21925919
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [ProDisc-C Total Disc Replacement. A four-year prospective monocentric study].
    Barna M; Stulík J; Kryl J; Vyskočil T; Nesnídal P
    Acta Chir Orthop Traumatol Cech; 2012; 79(6):512-9. PubMed ID: 23286683
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomy.
    Phillips FM; Voronov LI; Gaitanis IN; Carandang G; Havey RM; Patwardhan AG
    Spine J; 2006; 6(6):714-22. PubMed ID: 17088203
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The Differences Among Kinematic Parameters for Evaluating the Quality of Intervertebral Motion of the Cervical Spine in Clinical and Experimental Studies: Concepts, Research and Measurement Techniques. A Literature Review.
    Sang D; Cui W; Guo Z; Sang H; Liu B
    World Neurosurg; 2020 Jan; 133():343-357.e1. PubMed ID: 31550538
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The contribution of anulus fibers to torque resistance.
    Krismer M; Haid C; Rabl W
    Spine (Phila Pa 1976); 1996 Nov; 21(22):2551-7. PubMed ID: 8961442
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Paths of the cervical instantaneous axis of rotation during active movements-patterns and reliability.
    Venegas W; Inglés M; Page Á; Serra-Añó P
    Med Biol Eng Comput; 2020 May; 58(5):1147-1157. PubMed ID: 32193862
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements.
    Kurtz SM; Ciccarelli L; Harper ML; Siskey R; Shorez J; Chan FW
    Int J Spine Surg; 2012; 6():145-56. PubMed ID: 25694884
    [TBL] [Abstract][Full Text] [Related]  

  • 55. The role of axial torque in disc herniation.
    Marshall LW; McGill SM
    Clin Biomech (Bristol, Avon); 2010 Jan; 25(1):6-9. PubMed ID: 19815318
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A compliant-mechanism approach to achieving specific quality of motion in a lumbar total disc replacement.
    Halverson PA; Bowden AE; Howell LL
    Int J Spine Surg; 2012; 6():78-86. PubMed ID: 25694875
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Intravertebral neotrabecularization as an expression of focal load transfer by a keel-design lumbar total disc arthroplasty.
    Birkenmaier C; Boszczyk B; Baur-Melnyk A; Wegener B; Jansson V
    Arch Orthop Trauma Surg; 2011 Nov; 131(11):1481-4. PubMed ID: 21656195
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Eccentric head positions bias random generation of leftward and rightward handle-bar rotations.
    Heuer H; Klein W
    Acta Psychol (Amst); 2001 Jan; 106(1-2):23-49. PubMed ID: 11256337
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A device for measuring relative angular displacement.
    McCabe RP; Kohles SS; Chelikani SV; Vanderby R
    J Biomech Eng; 1998 Apr; 120(2):299-302. PubMed ID: 10412394
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A Facile and Flexible Method for On-Demand Directional Speed Tunability in the Miniaturised Lab-on-a-Disc.
    Tan MK; Siddiqi A; Yeo LY
    Sci Rep; 2017 Jul; 7(1):6652. PubMed ID: 28751783
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.