These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 23660299)

  • 21. A Rational Adoption of the High Sensitive Assay for Cardiac Troponin I in Diagnostic Routine.
    Croce A; Brunati P; Colzani C; Terramocci R; Favero S; Bordoni G; Galli C
    Dis Markers; 2017; 2017():4523096. PubMed ID: 28588346
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Cardiac troponin I cut-off: practice with the automated Immulite assay].
    Lavoinne A; Cauliez B
    Ann Biol Clin (Paris); 2003; 61(3):364-5. PubMed ID: 12825550
    [No Abstract]   [Full Text] [Related]  

  • 23. High-Sensitivity Troponin I and Rhythm Outcome after Electrical Cardioversion for Persistent Atrial Fibrillation.
    Horjen AW; Ulimoen SR; Seljeflot I; Smith P; Arnesen H; Norseth J; Tveit A
    Cardiology; 2016; 133(4):233-8. PubMed ID: 26697854
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Serial measurements of high sensitive cardiac troponin I in patients with acutely decompensated heart failure treated with carperitide or nitrates.
    Sato Y; Nishi K; Saijo S; Tanada Y; Goto T; Takahashi N; Yamamoto E; Fukuhara R; Miyamoto T; Taniguchi R; Fujiwara H; Takatsu Y
    J Cardiol; 2010 Jul; 56(1):66-72. PubMed ID: 20381318
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Early diagnosis of acute myocardial infarction in the elderly using more sensitive cardiac troponin assays.
    Reiter M; Twerenbold R; Reichlin T; Haaf P; Peter F; Meissner J; Hochholzer W; Stelzig C; Freese M; Heinisch C; Breidthardt T; Freidank H; Winkler K; Campodarve I; Gea J; Mueller C
    Eur Heart J; 2011 Jun; 32(11):1379-89. PubMed ID: 21362702
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Does undetectable troponin I at presentation using a contemporary sensitive assay rule out myocardial infarction? A cohort study.
    Kelly AM; Klim S
    Emerg Med J; 2015 Oct; 32(10):760-3. PubMed ID: 25552547
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of a modified lateral flow immunoassay for detection of high-sensitivity cardiac troponin I and myoglobin.
    Zhu J; Zou N; Mao H; Wang P; Zhu D; Ji H; Cong H; Sun C; Wang H; Zhang F; Qian J; Jin Q; Zhao J
    Biosens Bioelectron; 2013 Apr; 42():522-5. PubMed ID: 23247055
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of analytical performance of the Siemens ADVIA TnI ultra immunoassay.
    Prontera C; Fortunato A; Storti S; Mercuri A; Longombardo G; Zucchelli GC; Emdin M; Clerico A
    Clin Chem; 2007 Sep; 53(9):1722-3. PubMed ID: 17712017
    [No Abstract]   [Full Text] [Related]  

  • 29. Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay.
    van de Kerkhof D; Peters B; Scharnhorst V
    Ann Clin Biochem; 2008 May; 45(Pt 3):316-7. PubMed ID: 18482922
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Rapid and sensitive detection of troponin I in human whole blood samples by using silver nanoparticle films and microwave heating.
    Aslan K; Grell TA
    Clin Chem; 2011 May; 57(5):746-52. PubMed ID: 21398602
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reference values for cardiac troponins I and T in a goal-oriented concept of health: cardiac marker values in a series of outpatients without acute coronary syndromes.
    Möckel M; Danne O; Schmidt A; Goldmann M; Müller C; Dietz R; Wu AH
    Clin Chim Acta; 2004 Apr; 342(1-2):83-6. PubMed ID: 15026267
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A clinical and laboratory approach used to elucidate discordant results of high-sensitivity troponin T and troponin I.
    Franeková J; Bláha M; Bělohoubek J; Kotrbatá M; Sečník P; Kubíček Z; Kettner J; Jabor A
    Clin Chim Acta; 2015 Jun; 446():128-31. PubMed ID: 25896964
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Head-to-head comparison of high-sensitivity troponin T and sensitive-contemporary troponin I regarding heart failure risk stratification.
    de Antonio M; Lupón J; Galán A; Vila J; Zamora E; Urrutia A; Díez C; Coll R; Altimir S; Bayes-Genis A
    Clin Chim Acta; 2013 Nov; 426():18-24. PubMed ID: 23978483
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department.
    Aldous SJ; Florkowski CM; Crozier IG; Elliott J; George P; Lainchbury JG; Mackay RJ; Than M; Flaws DF; Borowsky J
    Ann Clin Biochem; 2011 May; 48(Pt 3):241-8. PubMed ID: 21441390
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical significance of low-positive troponin I by AxSYM and ACS:180.
    Lewis JS; Taylor JF; Miklos AZ; Virgo KS; Creer MH; Ritter DG
    Am J Clin Pathol; 2001 Sep; 116(3):396-402. PubMed ID: 11554168
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Characterisation of a highly sensitive troponin I assay and its application to a cardio-healthy population.
    Koerbin G; Tate J; Potter JM; Cavanaugh J; Glasgow N; Hickman PE
    Clin Chem Lab Med; 2012 Feb; 50(5):871-8. PubMed ID: 22628331
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Plasma cardiac troponin I concentrations in healthy neonates, children and adolescents measured with a high sensitive immunoassay method: High sensitive troponin I in pediatric age.
    Caselli C; Cangemi G; Masotti S; Ragusa R; Gennai I; Del Ry S; Prontera C; Clerico A
    Clin Chim Acta; 2016 Jul; 458():68-71. PubMed ID: 27118089
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Prognostic value of serial measurements of highly sensitive cardiac troponin I in stable outpatients with nonischemic chronic heart failure.
    Kawahara C; Tsutamoto T; Sakai H; Nishiyama K; Yamaji M; Fujii M; Yamamoto T; Horie M
    Am Heart J; 2011 Oct; 162(4):639-45. PubMed ID: 21982655
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prognostic value of troponin T, troponin I, and CK-MBmass in patients with chronic renal failure.
    Peetz D; Schütt S; Sucké B; Faldum A; Wandel E; Hafner G; Lackner KJ
    Med Klin (Munich); 2003 Apr; 98(4):188-92. PubMed ID: 12715142
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Beta-core fragment (beta-core/UGF/UGP), a tumor marker: a 7-year report.
    Cole LA; Tanaka A; Kim GS; Park SY; Koh MW; Schwartz PE; Chambers JT; Nam JH
    Gynecol Oncol; 1996 Feb; 60(2):264-70. PubMed ID: 8631549
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.