These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

261 related articles for article (PubMed ID: 23663659)

  • 1. Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer.
    Gasim GI; Musa IR; Abdien MT; Adam I
    BMC Res Notes; 2013 May; 6():194. PubMed ID: 23663659
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-contact infrared thermometers compared with current approaches in primary care for children aged 5 years and under: a method comparison study.
    Van den Bruel A; Verbakel J; Wang K; Fleming S; Holtman G; Glogowska M; Morris E; Edwards G; Abakar Ismail F; Curtis K; Goetz J; Barnes G; Slivkova R; Nesbitt C; Aslam S; Swift E; Williams H; Hayward G
    Health Technol Assess; 2020 Oct; 24(53):1-28. PubMed ID: 33111663
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Infrared tympanic thermometry compared to mercury thermometers].
    Valle PC; Kildahl-Andersen O; Steinvoll K
    Tidsskr Nor Laegeforen; 2000 Jan; 120(1):15-7. PubMed ID: 10815472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An evaluation of tympanic thermometry in a paediatric emergency department.
    El-Radhi AS; Patel S
    Emerg Med J; 2006 Jan; 23(1):40-1. PubMed ID: 16373802
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Non-contact infrared versus axillary and tympanic thermometers in children attending primary care: a mixed-methods study of accuracy and acceptability.
    Hayward G; Verbakel JY; Ismail FA; Edwards G; Wang K; Fleming S; Holtman GA; Glogowska M; Morris E; Curtis K; van den Bruel A
    Br J Gen Pract; 2020 Apr; 70(693):e236-e244. PubMed ID: 32205332
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting.
    Kocoglu H; Goksu S; Isik M; Akturk Z; Bayazit YA
    Int J Pediatr Otorhinolaryngol; 2002 Aug; 65(1):39-43. PubMed ID: 12127221
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparative study of tympanic and mercury thermometry in children].
    Montoya-Cabrera MA; Escalante-Galindo P; Flores-Alvarez E
    Gac Med Mex; 1998; 134(1):9-14. PubMed ID: 9658694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [FRONTAL, AXILLARY AND TYMPANIC TEMPERATURE MEASUREMENTS IN CHILDREN].
    Antabak A; Sisko J; Romić I; Papes D; Pasini M; Haluzan D; Bogović M; Medancić SS; Cavar S; Luetić T; Fuchs N; Andabak M; Prlić I; Curković S
    Lijec Vjesn; 2016; 138(1-2):30-3. PubMed ID: 27290811
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Infrared temperature measurement in the ear canal with the DIATEK 9000 Instatemp and the DIATEK 9000 Thermoguide. Comparison with methods of temperature measurement in other body parts].
    Fritz U; Rohrberg M; Lange C; Weyland W; Bräuer A; Braun U
    Anaesthesist; 1996 Nov; 45(11):1059-66. PubMed ID: 9012301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of axillary and infrared tympanic membrane thermometry in a pediatric oncology outpatient setting.
    Androkites AL; Werger AM; Young ML
    J Pediatr Oncol Nurs; 1998 Oct; 15(4):216-22. PubMed ID: 9810788
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Peripheral thermometry: Agreement between non-touch infrared versus traditional modes in an adult population.
    Sweeting P; Murphy M; Geraghty S; Duddle M
    J Adv Nurs; 2022 Feb; 78(2):425-433. PubMed ID: 34318950
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Reading children's temperatures with the tympanic infrared thermometer and the rectal mercury thermometer: equally good results in the emergency room].
    Draaisma JM; van Lemmen RJ; de Jong AA; Doesburg W
    Ned Tijdschr Geneeskd; 1997 May; 141(19):938-41. PubMed ID: 9340539
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cost effectiveness of tympanic thermometry in the pediatric office setting.
    Alexander D; Kelly B
    Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):57-9; discussion 60. PubMed ID: 1903097
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of tympanic and rectal temperatures in term Nigerian neonates.
    Duru CO; Akinbami FO; Orimadegun AE
    BMC Pediatr; 2012 Jun; 12():86. PubMed ID: 22731860
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers.
    Jensen BN; Jensen FS; Madsen SN; Løssl K
    Eur J Surg; 2000 Nov; 166(11):848-51. PubMed ID: 11097149
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer.
    Shenep JL; Adair JR; Hughes WT; Roberson PK; Flynn PM; Brodkey TO; Fullen GH; Kennedy WT; Oakes LL; Marina NM
    Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):36-41; discussion 49. PubMed ID: 2029817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies.
    Cultu O; Yildirim I; Ceyhan M; Korkmaz A; Yurdakök M; Karaağaoğlu E; Seçmeer G
    Turk J Pediatr; 2008; 50(4):354-8. PubMed ID: 19014049
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Temperature measurement in the ear canal: comparison of an infrared thermometer with conventional temperature probes and evaluation of clinical factors on infrared measurement].
    Rohrberg M; Fritz U; Weyland W; Braun U
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Jul; 32(7):409-13. PubMed ID: 9340028
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.