397 related articles for article (PubMed ID: 23665924)
1. Non-invasive monitoring of therapeutic carbon ion beams in a homogeneous phantom by tracking of secondary ions.
Gwosch K; Hartmann B; Jakubek J; Granja C; Soukup P; Jäkel O; Martišíková M
Phys Med Biol; 2013 Jun; 58(11):3755-73. PubMed ID: 23665924
[TBL] [Abstract][Full Text] [Related]
2. SU-D-BRB-02: Investigations of Secondary Ion Distributions in Carbon Ion Therapy Using the Timepix Detector.
Gwosch K; Hartmann B; Jakubek J; Granja C; Soukup P; Jaekel O; Martisikova M
Med Phys; 2012 Jun; 39(6Part3):3614-3615. PubMed ID: 28517381
[TBL] [Abstract][Full Text] [Related]
3. Visualization of air and metal inhomogeneities in phantoms irradiated by carbon ion beams using prompt secondary ions.
Gaa T; Reinhart M; Hartmann B; Jakubek J; Soukup P; Jäkel O; Martišíková M
Phys Med; 2017 Jun; 38():140-147. PubMed ID: 28576582
[TBL] [Abstract][Full Text] [Related]
4. Quality assurance method for monitoring of lateral pencil beam positions in scanned carbon-ion radiotherapy using tracking of secondary ions.
Félix-Bautista R; Ghesquière-Diérickx L; Marek L; Granja C; Soukup P; Turecek D; Kelleter L; Brons S; Ellerbrock M; Jäkel O; Gehrke T; Martišíková M
Med Phys; 2021 Aug; 48(8):4411-4424. PubMed ID: 34061994
[TBL] [Abstract][Full Text] [Related]
5. Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks.
Reinhart AM; Spindeldreier CK; Jakubek J; Martišíková M
Phys Med Biol; 2017 Jun; 62(12):4884-4896. PubMed ID: 28368853
[TBL] [Abstract][Full Text] [Related]
6. MO-A-213AB-11: First Experimental Test of Secondary Ion Tracking for the Assessment of Beam Range in a Patient-Like Phantom.
Martisikova M; Jakubek J; Gwosch K; Hartmann B; Telsemeyer J; Soukup P; Granja C; Pospisil S; Jaekel O
Med Phys; 2012 Jun; 39(6Part20):3861. PubMed ID: 28517543
[TBL] [Abstract][Full Text] [Related]
7. Experimental verification of a non-invasive method to monitor the lateral pencil beam position in an anthropomorphic phantom for carbon-ion radiotherapy.
Félix-Bautista R; Gehrke T; Ghesquière-Diérickx L; Reimold M; Amato C; Turecek D; Jakubek J; Ellerbrock M; Martišíková M
Phys Med Biol; 2019 Sep; 64(17):175019. PubMed ID: 31239428
[TBL] [Abstract][Full Text] [Related]
8. Design of a new tracking device for on-line beam range monitor in carbon therapy.
Traini G; Battistoni G; Bollella A; Collamati F; De Lucia E; Faccini R; Ferroni F; Frallicciardi PM; Mancini-Terracciano C; Marafini M; Mattei I; Miraglia F; Muraro S; Paramatti R; Piersanti L; Pinci D; Rucinski A; Russomando A; Sarti A; Sciubba A; Senzacqua M; Solfaroli-Camillocci E; Toppi M; Voena C; Patera V
Phys Med; 2017 Feb; 34():18-27. PubMed ID: 28111101
[TBL] [Abstract][Full Text] [Related]
9. Secondary radiation measurements for particle therapy applications: prompt photons produced by
Mattei I; Bini F; Collamati F; De Lucia E; Frallicciardi PM; Iarocci E; Mancini-Terracciano C; Marafini M; Muraro S; Paramatti R; Patera V; Piersanti L; Pinci D; Rucinski A; Russomando A; Sarti A; Sciubba A; Solfaroli Camillocci E; Toppi M; Traini G; Voena C; Battistoni G
Phys Med Biol; 2017 Feb; 62(4):1438-1455. PubMed ID: 28114112
[TBL] [Abstract][Full Text] [Related]
10. Secondary radiation measurements for particle therapy applications: charged particles produced by
Rucinski A; Battistoni G; Collamati F; De Lucia E; Faccini R; Frallicciardi PM; Mancini-Terracciano C; Marafini M; Mattei I; Muraro S; Paramatti R; Piersanti L; Pinci D; Russomando A; Sarti A; Sciubba A; Solfaroli Camillocci E; Toppi M; Traini G; Voena C; Patera V
Phys Med Biol; 2018 Mar; 63(5):055018. PubMed ID: 29265011
[TBL] [Abstract][Full Text] [Related]
11. Detecting perturbations of a radiation field inside a head-sized phantom exposed to therapeutic carbon-ion beams through charged-fragment tracking.
Ghesquière-Diérickx L; Félix-Bautista R; Schlechter A; Kelleter L; Reimold M; Echner G; Soukup P; Jäkel O; Gehrke T; Martišíková M
Med Phys; 2022 Mar; 49(3):1776-1792. PubMed ID: 35073413
[TBL] [Abstract][Full Text] [Related]
12. Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy.
Ableitinger A; Vatnitsky S; Herrmann R; Bassler N; Palmans H; Sharpe P; Ecker S; Chaudhri N; Jäkel O; Georg D
Radiother Oncol; 2013 Jul; 108(1):99-106. PubMed ID: 23886591
[TBL] [Abstract][Full Text] [Related]
13. Quantification of beta+ activity generated by hard photons by means of PET.
Möckel D; Müller H; Pawelke J; Sommer M; Will E; Enghardt W
Phys Med Biol; 2007 May; 52(9):2515-30. PubMed ID: 17440249
[TBL] [Abstract][Full Text] [Related]
14. Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams: comparison between water and PMMA targets.
Aricò G; Gehrke T; Jakubek J; Gallas R; Berke S; Jäkel O; Mairani A; Ferrari A; Martišíková M
Phys Med Biol; 2017 Oct; 62(20):8003-8024. PubMed ID: 28825918
[TBL] [Abstract][Full Text] [Related]
15. PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.
Pshenichnov I; Larionov A; Mishustin I; Greiner W
Phys Med Biol; 2007 Dec; 52(24):7295-312. PubMed ID: 18065840
[TBL] [Abstract][Full Text] [Related]
16. A novel method for assessment of fragmentation and beam-material interactions in helium ion radiotherapy with a miniaturized setup.
Gallas RR; Arico G; Burigo LN; Gehrke T; Jakůbek J; Granja C; Tureček D; Martišíková M
Phys Med; 2017 Oct; 42():116-126. PubMed ID: 29173904
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy.
Mirandola A; Molinelli S; Vilches Freixas G; Mairani A; Gallio E; Panizza D; Russo S; Ciocca M; Donetti M; Magro G; Giordanengo S; Orecchia R
Med Phys; 2015 Sep; 42(9):5287-300. PubMed ID: 26328978
[TBL] [Abstract][Full Text] [Related]
18. Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions.
Tessa CL; Berger T; Kaderka R; Schardt D; Burmeister S; Labrenz J; Reitz G; Durante M
Phys Med Biol; 2014 Apr; 59(8):2111-25. PubMed ID: 24694920
[TBL] [Abstract][Full Text] [Related]
19. Proof of principle of helium-beam radiography using silicon pixel detectors for energy deposition measurement, identification, and tracking of single ions.
Gehrke T; Gallas R; Jäkel O; Martišíková M
Med Phys; 2018 Feb; 45(2):817-829. PubMed ID: 29235123
[TBL] [Abstract][Full Text] [Related]
20. Influence of momentum acceptance on range monitoring of
Mohammadi A; Tashima H; Iwao Y; Takyu S; Akamatsu G; Kang HG; Nishikido F; Yoshida E; Chacon A; Safavi-Naeini M; Parodi K; Yamaya T
Phys Med Biol; 2020 Jun; 65(12):125006. PubMed ID: 32176873
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]