These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 23668920)

  • 1. The effect of stem surface treatment and material on pistoning of ulnar components in linked cemented elbow prostheses.
    Hosein YK; King GJ; Dunning CE
    J Shoulder Elbow Surg; 2013 Sep; 22(9):1248-55. PubMed ID: 23668920
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of stem material and surface treatment on the torsional stability at the metal-cement interface of upper limb joint replacement systems.
    Hosein YK; King GJ; Dunning CE
    J Biomed Mater Res B Appl Biomater; 2014 Aug; 102(6):1217-22. PubMed ID: 24644238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-vitro characteristics of cemented titanium femoral stems with a smooth surface finish.
    Akiyama H; Yamamoto K; Kaneuji A; Matsumoto T; Nakamura T
    J Orthop Sci; 2013 Jan; 18(1):29-37. PubMed ID: 22945910
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical bond strength of the cement-tibial component interface in total knee arthroplasty.
    Pittman GT; Peters CL; Hines JL; Bachus KN
    J Arthroplasty; 2006 Sep; 21(6):883-8. PubMed ID: 16950044
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Micromotion of plasma spray versus grit-blasted radial head prosthetic stem surfaces.
    Chanlalit C; Fitzsimmons JS; Shukla DR; An KN; O'Driscoll SW
    J Shoulder Elbow Surg; 2011 Jul; 20(5):717-22. PubMed ID: 21324417
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.
    Bader R; Steinhauser E; Holzwarth U; Schmitt M; Mittelmeier W
    Proc Inst Mech Eng H; 2004; 218(4):223-30. PubMed ID: 15376724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of rasp mismatch on plasma spray radial head stems.
    Shukla DR; Fitzsimmons JS; An KN; O'Driscoll SW
    J Shoulder Elbow Surg; 2012 Jul; 21(7):955-60. PubMed ID: 21856176
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of cross-sectional stem shape on the torsional stability of cemented implant components.
    Kedgley AE; Takaki SE; Lang P; Dunning CE
    J Biomech Eng; 2007 Jun; 129(3):310-4. PubMed ID: 17536897
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of material properties of femoral hip components on bone remodeling.
    Weinans H; Huiskes R; Grootenboer HJ
    J Orthop Res; 1992 Nov; 10(6):845-53. PubMed ID: 1403299
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of distal ulnar implant stem material and length on bone strains.
    Austman RL; Beaton BJ; Quenneville CE; King GJ; Gordon KD; Dunning CE
    J Hand Surg Am; 2007; 32(6):848-54. PubMed ID: 17606065
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.
    Ramaniraka NA; Rakotomanana LR; Leyvraz PF
    J Bone Joint Surg Br; 2000 Mar; 82(2):297-303. PubMed ID: 10755444
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ulnar component surface finish influenced the outcome of primary Coonrad-Morrey total elbow arthroplasty.
    Jeon IH; Morrey BF; Sanchez-Sotelo J
    J Shoulder Elbow Surg; 2012 Sep; 21(9):1229-35. PubMed ID: 22104128
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of proximal stem geometry and surface finish on the fixation of a double-tapered cemented femoral stem.
    Sangiorgio SN; Longjohn DB; Dorr LD; Ebramzadeh E
    J Biomech; 2011 Jan; 44(1):22-7. PubMed ID: 20828697
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Challenges in relating experimental hip implant fixation predictions to clinical observations.
    Sangiorgio SN; Longjohn DB; Dorr LD; Ebramzadeh E
    J Biomech; 2011 Jan; 44(2):235-43. PubMed ID: 21040920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component.
    Lewis JL; Askew MJ; Wixson RL; Kramer GM; Tarr RR
    J Bone Joint Surg Am; 1984 Feb; 66(2):280-6. PubMed ID: 6693456
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
    Behairy YM; Harris WH
    Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Silicate coating of cemented titanium-based shafts in hip prosthetics reduces high aseptic loosening].
    Marx R; Faramarzi R; Jungwirth F; Kleffner BV; Mumme T; Weber M; Wirtz DC
    Z Orthop Unfall; 2009; 147(2):175-82. PubMed ID: 19358071
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Bone cement adhesion on ceramic surfaces - surface activation of retention surfaces of knee prostheses by atmospheric plasma versus thermal surface treatment].
    Marx B; Marx R; Reisgen U; Wirtz D
    Z Orthop Unfall; 2015 Apr; 153(2):146-52. PubMed ID: 25874392
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.