338 related articles for article (PubMed ID: 23671203)
1. Is anti-platelet therapy needed in continuous flow left ventricular assist device patients? A single-centre experience.
Litzler PY; Smail H; Barbay V; Nafeh-Bizet C; Bouchart F; Baste JM; Abriou C; Bessou JP
Eur J Cardiothorac Surg; 2014 Jan; 45(1):55-9; discussion 59-60. PubMed ID: 23671203
[TBL] [Abstract][Full Text] [Related]
2. Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device.
Stulak JM; Lee D; Haft JW; Romano MA; Cowger JA; Park SJ; Aaronson KD; Pagani FD
J Heart Lung Transplant; 2014 Jan; 33(1):60-4. PubMed ID: 24021944
[TBL] [Abstract][Full Text] [Related]
3. Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.
John R; Kamdar F; Liao K; Colvin-Adams M; Miller L; Joyce L; Boyle A
J Thorac Cardiovasc Surg; 2008 Nov; 136(5):1318-23. PubMed ID: 19026822
[TBL] [Abstract][Full Text] [Related]
4. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation.
Uriel N; Pak SW; Jorde UP; Jude B; Susen S; Vincentelli A; Ennezat PV; Cappleman S; Naka Y; Mancini D
J Am Coll Cardiol; 2010 Oct; 56(15):1207-13. PubMed ID: 20598466
[TBL] [Abstract][Full Text] [Related]
5. Assessment of platelet function with light transmission aggregometry in 24 patients supported with a continuous-flow left ventricular assist device: a single-center experience.
Fiore M; James C; Mouton C; Calderon J; Barandon L; Ouattara A; Picard F
J Thorac Cardiovasc Surg; 2014 Dec; 148(6):3119-25.e1. PubMed ID: 25212058
[TBL] [Abstract][Full Text] [Related]
6. Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD.
Stern DR; Kazam J; Edwards P; Maybaum S; Bello RA; D'Alessandro DA; Goldstein DJ
J Card Surg; 2010 May; 25(3):352-6. PubMed ID: 20331479
[TBL] [Abstract][Full Text] [Related]
7. Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation.
Boyle AJ; Russell SD; Teuteberg JJ; Slaughter MS; Moazami N; Pagani FD; Frazier OH; Heatley G; Farrar DJ; John R
J Heart Lung Transplant; 2009 Sep; 28(9):881-7. PubMed ID: 19716039
[TBL] [Abstract][Full Text] [Related]
8. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
[TBL] [Abstract][Full Text] [Related]
9. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.
Birschmann I; Dittrich M; Eller T; Wiegmann B; Reininger AJ; Budde U; Strüber M
J Heart Lung Transplant; 2014 Jan; 33(1):80-7. PubMed ID: 24418734
[TBL] [Abstract][Full Text] [Related]
10. Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients.
Boyle AJ; Jorde UP; Sun B; Park SJ; Milano CA; Frazier OH; Sundareswaran KS; Farrar DJ; Russell SD;
J Am Coll Cardiol; 2014 Mar; 63(9):880-8. PubMed ID: 24316083
[TBL] [Abstract][Full Text] [Related]
11. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease.
Geisen U; Heilmann C; Beyersdorf F; Benk C; Berchtold-Herz M; Schlensak C; Budde U; Zieger B
Eur J Cardiothorac Surg; 2008 Apr; 33(4):679-84. PubMed ID: 18282712
[TBL] [Abstract][Full Text] [Related]
12. Time course of acquired von Willebrand disease associated with two types of continuous-flow left ventricular assist devices: HeartMate II and CircuLite Synergy Pocket Micro-pump.
Goda M; Jacobs S; Rega F; Peerlinck K; Jacquemin M; Droogne W; Vanhaecke J; Van Cleemput J; Van den Bossche K; Meyns B
J Heart Lung Transplant; 2013 May; 32(5):539-45. PubMed ID: 23570742
[TBL] [Abstract][Full Text] [Related]
13. Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.
Meyer AL; Malehsa D; Budde U; Bara C; Haverich A; Strueber M
JACC Heart Fail; 2014 Apr; 2(2):141-5. PubMed ID: 24720921
[TBL] [Abstract][Full Text] [Related]
14. Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation.
Stulak JM; Deo S; Schirger J; Aaronson KD; Park SJ; Joyce LD; Daly RC; Pagani FD
Ann Thorac Surg; 2013 Dec; 96(6):2161-7. PubMed ID: 24035302
[TBL] [Abstract][Full Text] [Related]
15. Use of left ventricular assist device (HeartMate II): a Singapore experience.
Lim CP; Sivathasan C; Tan TE; Lim CH; Kerk KL; Sim DK
Artif Organs; 2014 Jul; 38(7):543-8. PubMed ID: 24392937
[TBL] [Abstract][Full Text] [Related]
16. Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device.
Meyer AL; Malehsa D; Bara C; Budde U; Slaughter MS; Haverich A; Strueber M
Circ Heart Fail; 2010 Nov; 3(6):675-81. PubMed ID: 20739614
[TBL] [Abstract][Full Text] [Related]
17. Post-cardiac transplant survival after support with a continuous-flow left ventricular assist device: impact of duration of left ventricular assist device support and other variables.
John R; Pagani FD; Naka Y; Boyle A; Conte JV; Russell SD; Klodell CT; Milano CA; Rogers J; Farrar DJ; Frazier OH
J Thorac Cardiovasc Surg; 2010 Jul; 140(1):174-81. PubMed ID: 20447659
[TBL] [Abstract][Full Text] [Related]
18. Outcomes after implantation of 139 full-support continuous-flow left ventricular assist devices as a bridge to transplantation.
Sabashnikov A; Mohite PN; Weymann A; Patil NP; Hedger M; Sáez DG; Zych B; Wahlers T; Wippermann J; De Robertis F; Bahrami T; Amrani M; Simon AR; Popov AF
Eur J Cardiothorac Surg; 2014 Nov; 46(5):e59-66. PubMed ID: 25180072
[TBL] [Abstract][Full Text] [Related]
19. Low stroke rate and few thrombo-embolic events after HeartMate II implantation under mild anticoagulation.
Menon AK; Götzenich A; Sassmannshausen H; Haushofer M; Autschbach R; Spillner JW
Eur J Cardiothorac Surg; 2012 Aug; 42(2):319-23; discussion 323. PubMed ID: 22398471
[TBL] [Abstract][Full Text] [Related]
20. Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy.
Slaughter MS; Naka Y; John R; Boyle A; Conte JV; Russell SD; Aaronson KD; Sundareswaran KS; Farrar DJ; Pagani FD
J Heart Lung Transplant; 2010 Jun; 29(6):616-24. PubMed ID: 20400335
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]