BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

263 related articles for article (PubMed ID: 23672091)

  • 1. [New stream for the measurement of anti-platelet factor 4/heparin antibodies].
    Sakata T
    Rinsho Byori; 2013 Feb; 61(2):137-43. PubMed ID: 23672091
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a new automated panel of assays for the detection of anti-PF4/heparin antibodies in patients suspected of having heparin-induced thrombocytopenia.
    Legnani C; Cini M; Pili C; Boggian O; Frascaro M; Palareti G
    Thromb Haemost; 2010 Aug; 104(2):402-9. PubMed ID: 20539902
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of two new automated chemiluminescent assays (HemosIL® AcuStar HIT-IgG and HemosIL® AcuStar HIT-Ab) for the detection of heparin-induced antibodies in the diagnosis of heparin-induced thrombocytopenia.
    Van Hoecke F; Devreese K
    Int J Lab Hematol; 2012 Aug; 34(4):410-6. PubMed ID: 22405611
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of automated immunoassays in the diagnosis of heparin induced thrombocytopenia.
    Althaus K; Hron G; Strobel U; Abbate R; Rogolino A; Davidson S; Greinacher A; Bakchoul T
    Thromb Res; 2013 Mar; 131(3):e85-90. PubMed ID: 23351665
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.
    Nagler M; Cuker A
    Expert Rev Mol Diagn; 2017 May; 17(5):419-426. PubMed ID: 28271738
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of a new, rapid, automated immunoassay for the detection of anti-platelet factor 4/heparin complex antibodies.
    Davidson SJ; Ortel TL; Smith LJ
    Blood Coagul Fibrinolysis; 2011 Jun; 22(4):340-4. PubMed ID: 21415710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prospective evaluation of automatized PF4/heparin immunoassays HemosIL HIT-ab (PF4-H) for the diagnosis of heparin-induced thrombocytopenia.
    Jourdy Y; Nougier C; Rugeri L; Bordet JC; Sobas F; Negrier C
    Int J Lab Hematol; 2015 Apr; 37(2):244-52. PubMed ID: 25041633
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of the performances of AcuStar HIT and the combination with heparin-induced multiple electrode aggregometry: a retrospective study.
    Minet V; Bailly N; Douxfils J; Osselaer JC; Laloy J; Chatelain C; Elalamy I; Chatelain B; Dogné JM; Mullier F
    Thromb Res; 2013 Sep; 132(3):352-9. PubMed ID: 23803389
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of three different immunoassays in the diagnosis of heparin-induced thrombocytopenia.
    Vianello F; Sambado L; Scarparo P; Lombardi A; Bernardi D; Plebani M; Fabris F
    Clin Chem Lab Med; 2015 Feb; 53(2):257-63. PubMed ID: 25324455
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical validation of immunoassay HemosIL® AcuStar HIT-IgG (PF4-H) in the diagnosis of Heparin-induced thrombocytopenia.
    Marashi-Sabouni Z; Vayne C; Ibrahim-Kosta M; Guidon C; Loundou A; Guery EA; Morange PE; Camoin-Jau L
    J Thromb Thrombolysis; 2021 Aug; 52(2):601-609. PubMed ID: 33386560
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and clinical significance of anti-PF4/heparin antibodies of the IgG, IgM, and IgA class in 755 consecutive patient samples referred for diagnostic testing for heparin-induced thrombocytopenia.
    Juhl D; Eichler P; Lubenow N; Strobel U; Wessel A; Greinacher A
    Eur J Haematol; 2006 May; 76(5):420-6. PubMed ID: 16466367
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid exclusion of the diagnosis of immune HIT by AcuStar HIT and heparin-induced multiple electrode aggregometry.
    Minet V; Baudar J; Bailly N; Douxfils J; Laloy J; Lessire S; Gourdin M; Devalet B; Chatelain B; Dogné JM; Mullier F
    Thromb Res; 2014 Jun; 133(6):1074-8. PubMed ID: 24485951
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dimeric FcγR ectodomains detect pathogenic anti-platelet factor 4-heparin antibodies in heparin-induced thromobocytopenia.
    Wines BD; Tan CW; Duncan E; McRae S; Baker RI; Andrews RK; Esparon S; Gardiner EE; Hogarth PM
    J Thromb Haemost; 2018 Dec; 16(12):2520-2525. PubMed ID: 30269432
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid and accurate Bayesian diagnosis of heparin-induced thrombocytopenia.
    Marchetti M; Barelli S; Zermatten MG; Monnin-Respen F; Matthey-Guirao E; Nicolas N; Gomez F; Goodyer M; Gerschheimer C; Alberio L
    Blood; 2020 Apr; 135(14):1171-1184. PubMed ID: 31945147
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance characteristics of an automated latex immunoturbidimetric assay [HemosIL
    Warkentin TE; Sheppard JI; Linkins LA; Arnold DM; Nazy I
    Thromb Res; 2017 May; 153():108-117. PubMed ID: 28391124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence and clinical relevance of anti-platelet factor 4/heparin antibodies before cardiac surgery.
    Selleng S; Malowsky B; Itterman T; Bagemühl J; Wessel A; Wollert HG; Warkentin TE; Greinacher A
    Am Heart J; 2010 Aug; 160(2):362-9. PubMed ID: 20691844
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of a new immunoassay for the diagnosis of heparin-induced thrombocytopenia and improved specificity when detecting IgG antibodies.
    Pouplard C; Leroux D; Regina S; Rollin J; Gruel Y
    Thromb Haemost; 2010 Jan; 103(1):145-50. PubMed ID: 20062918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Platelet factor 4, target of anti-heparin antibodies: application to biological diagnosis of heparin-induced thrombopenia].
    Amiral J
    Ann Med Interne (Paris); 1997; 148(2):142-9. PubMed ID: 9238439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of laboratory diagnosis of heparin-induced thrombocytopenia using HemosIL-AcuStar-HIT-IgG assay.
    Tucker CM; Rhoades R; Sharma R; Gong JZ
    Lab Med; 2024 Jan; 55(1):34-39. PubMed ID: 37094798
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New insights in heparin-induced thrombocytopenia by the use of fluid-phase assays to detect specifically platelet factor 4/heparin complex antibodies and antibody-secreting cells.
    Schulze A; Jensch I; Krauel K; Alahmad A; Müller HP; Greinacher A; Hundt M
    Thromb Res; 2014 Jul; 134(1):174-81. PubMed ID: 24816371
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.