These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
471 related articles for article (PubMed ID: 23674479)
1. Management of severe aortic regurgitation in a patient with cardiogenic shock using a percutaneous left ventricular assist device and transcatheter occlusion of the failed aortic valve homograft as a bridge to surgical valve replacement. Pollak P; Lim DS; Kern J Catheter Cardiovasc Interv; 2014 Jan; 83(1):E141-5. PubMed ID: 23674479 [TBL] [Abstract][Full Text] [Related]
2. Cardiogenic Shock Complicating Transcatheter Aortic Valve Replacement Due to Severe Para-Valvular Regurgitation. Alraies MC; Soud M; Pacha HM; Waksman R; Ben-Dor I Cardiovasc Revasc Med; 2018; 19(3 Pt B):393-395. PubMed ID: 29146552 [TBL] [Abstract][Full Text] [Related]
3. Abnormal distortion of aortic corevalve bioprosthesis with suicide left ventricle, aortic insufficiency, and severe mitral regurgitation during transcatheter aortic valve replacement. Leya F; Tuchek JM; Coats W Catheter Cardiovasc Interv; 2016 Dec; 88(7):1181-1187. PubMed ID: 26945836 [TBL] [Abstract][Full Text] [Related]
4. Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics. Parikh KS; Mehrotra AK; Russo MJ; Lang RM; Anderson A; Jeevanandam V; Freed BH; Paul JD; Karol J; Nathan S; Shah AP JACC Cardiovasc Interv; 2013 Jan; 6(1):84-9. PubMed ID: 23347865 [TBL] [Abstract][Full Text] [Related]
5. Transcatheter Mitral Valve Implantation in a Patient With an Aortic Mechanical Valve. van Gils L; Rodriguez Olivares R; Ren B; Geleijnse ML; Kappetein AP; De Jaegere PPT; Van Mieghem NM JACC Cardiovasc Interv; 2016 Feb; 9(4):e31-e33. PubMed ID: 26892092 [No Abstract] [Full Text] [Related]
6. CoreValve degeneration with severe transvalvular aortic regurgitation treated with valve-in-valve implantation. Sinning JM; Vasa-Nicotera M; Werner N; Zimmer S; Mellert F; Welz A; Grube E; Nickenig G; Hammerstingl C JACC Cardiovasc Interv; 2014 Jul; 7(7):e71-2. PubMed ID: 24954574 [No Abstract] [Full Text] [Related]
7. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis. Attia R; Bapat V Catheter Cardiovasc Interv; 2013 Aug; 82(2):324-7. PubMed ID: 22120953 [TBL] [Abstract][Full Text] [Related]
8. Percutaneous left ventricular support in cardiogenic shock and severe aortic regurgitation. Pham DT; Al-Quthami A; Kapur NK Catheter Cardiovasc Interv; 2013 Feb; 81(2):399-401. PubMed ID: 22639446 [TBL] [Abstract][Full Text] [Related]
9. Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses--valve-in-valve technique. Gotzmann M; Mügge A; Bojara W Catheter Cardiovasc Interv; 2010 Dec; 76(7):1000-6. PubMed ID: 20824744 [TBL] [Abstract][Full Text] [Related]
10. Transcatheter Aortic Valve-in-Valve Replacement Instead of a 4th Sternotomy in a 21-Year-Old Woman with Aortic Homograft Failure. Díez JG; Schechter M; Dougherty KG; Preventza O; Coselli JS Tex Heart Inst J; 2016 Aug; 43(4):334-7. PubMed ID: 27547146 [TBL] [Abstract][Full Text] [Related]
11. Percutaneous transcatheter closure of the native aortic valve to treat de novo aortic insufficiency after implantation of a left ventricular assist device. Freed BH; Paul JD; Bhave NM; Russo MJ; Jeevanandam V; Lang RM; Shah AP JACC Cardiovasc Interv; 2012 Mar; 5(3):358-9. PubMed ID: 22440504 [No Abstract] [Full Text] [Related]
12. Transseptal transcatheter mitral valve-in-valve for treatment of severe mitral regurgitation in failed bioprosthesis complicated with cardiogenic shock: Case report and review of the literature. Rufian-Andujar S; Iftikhar O; Salinger M; Saucedo J; Feldman T; Guerrero M Cardiovasc Revasc Med; 2018; 19(7 Pt B):874-878. PubMed ID: 29636301 [TBL] [Abstract][Full Text] [Related]
13. First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve. Binder RK; Wood D; Webb JG; Cheung A Catheter Cardiovasc Interv; 2013 Dec; 82(7):E929-31. PubMed ID: 22821872 [TBL] [Abstract][Full Text] [Related]
14. Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves. Sarkar K; Sardella G; Romeo F; De Benedictis M; Tarsia G; Iadanza A; Sharma SK; Barbanti M; Tamburino C; Ussia GP Catheter Cardiovasc Interv; 2013 Apr; 81(5):864-70. PubMed ID: 22997004 [TBL] [Abstract][Full Text] [Related]
15. Paravalvular leak closure of a native aortic valve for cardiogenic shock post valvular surgery. Lochy S; Galloo X; Droogmans S; Eeckhout E Catheter Cardiovasc Interv; 2024 Oct; 104(4):858-861. PubMed ID: 38971970 [TBL] [Abstract][Full Text] [Related]
16. Percutaneous transcatheter closure of the aortic valve to treat cardiogenic shock in a left ventricular assist device patient with severe aortic insufficiency. Russo MJ; Freed BH; Jeevanandam V; Hashmi M; Paul JD; Anderson A; Lang RM; Shah AP Ann Thorac Surg; 2012 Sep; 94(3):985-8. PubMed ID: 22916753 [TBL] [Abstract][Full Text] [Related]
17. Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience. Dranishnikov N; Stepanenko A; Potapov EV; Dandel M; Siniawski H; Mladenow A; Hübler M; Grauhan O; Weng Y; Krabatsch T; Hetzer R; Kukucka M Int J Artif Organs; 2012 Jul; 35(7):489-94. PubMed ID: 22661109 [TBL] [Abstract][Full Text] [Related]
18. Transfemoral aortic valve-in-valve implantation with a balloon-expandable valve for the treatment of stentless xenograft severe aortic regurgitation. Bagur R; Rodés-Cabau J; De Larochellière R; Doyle D; Rheault M; Dumont E JACC Cardiovasc Interv; 2011 Nov; 4(11):1248-9. PubMed ID: 22115667 [No Abstract] [Full Text] [Related]
19. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Sieswerda G; Budde R; van der Linden M; Juthier F; Banfi C; Hurt C; Samim M; Hillaert M; van Herwerden L; Bertrand ME; Doevendans PA; Van Belle E J Thorac Cardiovasc Surg; 2013 Feb; 145(2):398-405. PubMed ID: 22377664 [TBL] [Abstract][Full Text] [Related]
20. Transcatheter aortic valve implantation for severe aortic regurgitation in a stentless bioprosthetic valve with the Core Valve revalving system-technical tips and role of the Accutrak system. Sarkar K; Ussia GP; Tamburino C Catheter Cardiovasc Interv; 2011 Sep; 78(3):485-90. PubMed ID: 21557449 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]