BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1195 related articles for article (PubMed ID: 23684679)

  • 1. The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial.
    Binder RK; Webb JG; Willson AB; Urena M; Hansson NC; Norgaard BL; Pibarot P; Barbanti M; Larose E; Freeman M; Dumont E; Thompson C; Wheeler M; Moss RR; Yang TH; Pasian S; Hague CJ; Nguyen G; Raju R; Toggweiler S; Min JK; Wood DA; Rodés-Cabau J; Leipsic J
    J Am Coll Cardiol; 2013 Jul; 62(5):431-8. PubMed ID: 23684679
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.
    Willson AB; Webb JG; Labounty TM; Achenbach S; Moss R; Wheeler M; Thompson C; Min JK; Gurvitch R; Norgaard BL; Hague CJ; Toggweiler S; Binder R; Freeman M; Poulter R; Poulsen S; Wood DA; Leipsic J
    J Am Coll Cardiol; 2012 Apr; 59(14):1287-94. PubMed ID: 22365423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial.
    Willson AB; Webb JG; Freeman M; Wood DA; Gurvitch R; Thompson CR; Moss RR; Toggweiler S; Binder RK; Munt B; Cheung A; Hague C; Ye J; Leipsic JA
    J Cardiovasc Comput Tomogr; 2012; 6(6):406-14. PubMed ID: 23127390
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predictive value for paravalvular regurgitation of 3-dimensional anatomic aortic annulus shape assessed by multidetector computed tomography post-transcatheter aortic valve replacement.
    Ciobotaru V; Maupas E; Dürrleman N; Boulenc JM; Borton A; Pujadas-Berthault P; Rioux P; Maubon A
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):85-95. PubMed ID: 26003147
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Methodologic Differences in Three-Dimensional Echocardiographic Measurements of the Aortic Annulus Compared with Computed Tomographic Angiography Before Transcatheter Aortic Valve Replacement.
    Khalique OK; Hamid NB; White JM; Bae DJ; Kodali SK; Nazif TM; Vahl TP; Paradis JM; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2017 Apr; 30(4):414-421. PubMed ID: 27939049
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?
    Hafiz AM; Medranda GA; Kakouros N; Patel J; Kahan J; Gubernikoff G; Ray B; Paruchuri V; DeLeon J; Marzo K; Calixte R; Gaztanaga J
    Echocardiography; 2017 Aug; 34(8):1195-1202. PubMed ID: 28722306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing.
    Condado JF; Lerakis S; Stewart J; Jensen H; Henry TS; Ko SM; Stillman A; Rajaei MH; Mavromatis K; Devireddy C; Sarin E; Leshnower B; Guyton R; Kaebnick B; Thourani VH; Block PC; Babaliaros V
    J Invasive Cardiol; 2016 Jul; 28(7):295-304. PubMed ID: 27101969
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
    Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography.
    Pontone G; Andreini D; Bartorelli AL; Bertella E; Cortinovis S; Mushtaq S; Annoni A; Formenti A; Baggiano A; Conte E; Tamborini G; Muratori M; Gripari P; Bovis F; Veglia F; Foti C; Alamanni F; Ballerini G; Fiorentini C; Pepi M
    Am Heart J; 2012 Oct; 164(4):576-84. PubMed ID: 23067917
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: predictive value for aortic regurgitation after transcatheter aortic valve replacement.
    Masri A; Schoenhagen P; Svensson L; Kapadia SR; Griffin BP; Tuzcu EM; Desai MY
    J Thorac Cardiovasc Surg; 2014 Jun; 147(6):1847-54. PubMed ID: 23870156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.
    Khalique OK; Kodali SK; Paradis JM; Nazif TM; Williams MR; Einstein AJ; Pearson GD; Harjai K; Grubb K; George I; Leon MB; Hahn RT
    Circ Cardiovasc Imaging; 2014 Jan; 7(1):155-63. PubMed ID: 24221192
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated 3D analysis of pre-procedural MDCT to predict annulus plane angulation and C-arm positioning: benefit on procedural outcome in patients referred for TAVR.
    Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Budde RP; Sieswerda G; Algeri E; van Belle C; Elkalioubie A; Juthier F; Belkacemi A; Bertrand ME; Doevendans PA; Van Belle E
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):238-48. PubMed ID: 23489538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation.
    Binder RK; Webb JG; Toggweiler S; Freeman M; Barbanti M; Willson AB; Alhassan D; Hague CJ; Wood DA; Leipsic J
    JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurements of the aortic annulus.
    Hahn RT; Khalique O; Williams MR; Koss E; Paradis JM; Daneault B; Kirtane AJ; George I; Leon MB; Kodali S
    J Am Soc Echocardiogr; 2013 Sep; 26(9):1043-52. PubMed ID: 23998695
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 60.