These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 23692572)

  • 1. Application of combined EBSD and 3D-SEM technique on crystallographic facet analysis of steel at low temperature.
    Mohseni P; Solberg JK; Karlsen M; Akselsen OM; Ostby E
    J Microsc; 2013 Jul; 251(1):45-56. PubMed ID: 23692572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of electron backscatter diffraction (EBSD) to fracture studies of ferritic steels.
    Davies PA; Novovic M; Randle V; Bowen P
    J Microsc; 2002 Mar; 205(Pt 3):278-84. PubMed ID: 11996192
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quasi-cleavage fracture planes in spheroidized A533B steel.
    Kumar A; Wilkinson AJ; Roberts SG
    J Microsc; 2007 Sep; 227(Pt 3):248-53. PubMed ID: 17760620
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combined application of electron backscatter diffraction and stereo-photogrammetry in fractography studies.
    Davies PA; Randle V
    J Microsc; 2001 Oct; 204(Pt 1):29-38. PubMed ID: 11580810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of fatigue crack initiation facets in Ti-6Al-4V using focused ion beam milling and electron backscatter diffraction.
    Everaerts J; Verlinden B; Wevers M
    J Microsc; 2017 Jul; 267(1):57-69. PubMed ID: 28294326
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Crystallographic analysis of facets using electron backscatter diffraction.
    Randle V
    J Microsc; 1999 Sep; 195(3):226-232. PubMed ID: 10460688
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tensile Deformation and Fracture Behavior of API-5L X70 Line Pipe Steel.
    Lobanov ML; Khotinov VA; Urtsev VN; Danilov SV; Urtsev NV; Platov SI; Stepanov SI
    Materials (Basel); 2022 Jan; 15(2):. PubMed ID: 35057219
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electron backscatter diffraction on pearlite structures in steel.
    Walentek A; Seefeldt M; Verlinden B; Aernoudt E; Van Houtte P
    J Microsc; 2006 Dec; 224(Pt 3):256-63. PubMed ID: 17210058
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physical matching of metals: grain orientation association at fracture edge.
    Lograsso BK
    J Forensic Sci; 2015 Jan; 60 Suppl 1():S66-75. PubMed ID: 25619870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Fracture Toughness in the Coarse-Grain Heat-Affected Zone of X80 Pipelines Girth-Welded under Conventional and Ultra-Low Heat Input.
    Liu S; Ba L; Li C; Di X
    Materials (Basel); 2022 Nov; 15(21):. PubMed ID: 36363293
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional characterization of ODS ferritic steel using by FIB-SEM serial sectioning method.
    Endo T; Sugino Y; Ohono N; Ukai S; Miyazaki N; Wang Y; Ohnuki S
    Microscopy (Oxf); 2014 Nov; 63 Suppl 1():i23. PubMed ID: 25359819
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Recrystallization phenomena in an IF steel observed by in situ EBSD experiments.
    Nakamichi H; Humphreys FJ; Brough I
    J Microsc; 2008 Jun; 230(Pt 3):464-71. PubMed ID: 18503673
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Crystallographic orientation data from chloride-induced stress corrosion crack (CISCC) paths in gas tungsten arc welded (GTAW) austenitic stainless steel 304L.
    Qu HJ; Wharry JP
    Data Brief; 2022 Jun; 42():108059. PubMed ID: 35345845
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-temperature electron backscatter diffraction and scanning electron microscopy imaging techniques: in-situ investigations of dynamic processes.
    Seward GG; Prior DJ; Wheeler J; Celotto S; Halliday DJ; Paden RS; Tye MR
    Scanning; 2002; 24(5):232-40. PubMed ID: 12392354
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of the easy axes of small ferromagnetic precipitates in a bulk material by combined magnetic force microscopy and electron backscatter diffraction techniques.
    Batista L; Rabe U; Hirsekorn S
    Ultramicroscopy; 2014 Nov; 146():17-26. PubMed ID: 24887154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation into experimental in situ scanning electron microscope (SEM) imaging at high temperature.
    Heard R; Huber JE; Siviour C; Edwards G; Williamson-Brown E; Dragnevski K
    Rev Sci Instrum; 2020 Jun; 91(6):063702. PubMed ID: 32611037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Morphological analyses of minute crystals by using stereo-photogrammetric scanning electron microscopy and electron back-scattered diffraction.
    Kameda J; Inoguchi R; Prior DJ; Kogure T
    J Microsc; 2007 Dec; 228(Pt 3):358-65. PubMed ID: 18045330
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of electron backscatter diffraction for crystallographic characterization of tin whiskers.
    Michael JR; McKenzie BB; Susan DF
    Microsc Microanal; 2012 Aug; 18(4):876-84. PubMed ID: 22832083
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of crystallographic texture on Young's modulus of various Alloy 82H welds.
    Claves SR; Mills WJ
    Microsc Microanal; 2011 Jun; 17(3):341-9. PubMed ID: 21473809
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Site-specific fracture plane determination using the FIB/TEM.
    Hackenberg RE; Field RD; Papin PA; Cooley JC; Teter DF
    Ultramicroscopy; 2007 Aug; 107(8):698-702. PubMed ID: 17350170
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.