These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

864 related articles for article (PubMed ID: 23696688)

  • 1. A comparison of leak compensation in acute care ventilators during noninvasive and invasive ventilation: a lung model study.
    Oto J; Chenelle CT; Marchese AD; Kacmarek RM
    Respir Care; 2013 Dec; 58(12):2027-37. PubMed ID: 23696688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of leak compensation during pediatric noninvasive ventilation: a lung model study.
    Oto J; Chenelle CT; Marchese AD; Kacmarek RM
    Respir Care; 2014 Feb; 59(2):241-51. PubMed ID: 23821761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Leak Compensation on Patient-Ventilator Synchrony During Premature/Neonatal Invasive and Noninvasive Ventilation: A Lung Model Study.
    Itagaki T; Chenelle CT; Bennett DJ; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):22-33. PubMed ID: 27651525
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A comparison of leak compensation in six acute care ventilators during non-invasive ventilation].
    Hu XS; Wang Y; Wang ZT; Yan P; Zhang XG; Zhao SF; Xie F; Gu HJ; Xie LX
    Zhonghua Jie He He Hu Xi Za Zhi; 2017 Feb; 40(2):90-97. PubMed ID: 28209038
    [No Abstract]   [Full Text] [Related]  

  • 5. Bilevel vs ICU ventilators providing noninvasive ventilation: effect of system leaks: a COPD lung model comparison.
    Ferreira JC; Chipman DW; Hill NS; Kacmarek RM
    Chest; 2009 Aug; 136(2):448-456. PubMed ID: 19429723
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive ventilator triggering in chronic obstructive pulmonary disease. A test lung comparison.
    Stell IM; Paul G; Lee KC; Ponte J; Moxham J
    Am J Respir Crit Care Med; 2001 Dec; 164(11):2092-7. PubMed ID: 11739140
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.
    Chen Y; Cheng K; Zhou X
    Med Sci Monit; 2015 Jan; 21():310-7. PubMed ID: 25619202
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a nasal cannula in noninvasive ventilation using a lung simulator.
    Iyer NP; Chatburn R
    Respir Care; 2015 Apr; 60(4):508-12. PubMed ID: 25492958
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined effects of leaks, respiratory system properties and upper airway patency on the performance of home ventilators: a bench study.
    Zhu K; Rabec C; Gonzalez-Bermejo J; Hardy S; Aouf S; Escourrou P; Roisman G
    BMC Pulm Med; 2017 Nov; 17(1):145. PubMed ID: 29157220
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.
    Itagaki T; Bennett DJ; Chenelle CT; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):10-21. PubMed ID: 27879380
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neonatal and adult ICU ventilators to provide ventilation in neonates, infants, and children: a bench model study.
    Vignaux L; Piquilloud L; Tourneux P; Jolliet P; Rimensberger PC
    Respir Care; 2014 Oct; 59(10):1463-75. PubMed ID: 25118306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient-Ventilator Interaction During Noninvasive Ventilation in Simulated COPD.
    Moerer O; Harnisch LO; Herrmann P; Zippel C; Quintel M
    Respir Care; 2016 Jan; 61(1):15-22. PubMed ID: 26556898
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effectiveness of Inspiratory Termination Synchrony with Automatic Cycling During Noninvasive Pressure Support Ventilation.
    Chen Y; Cheng K; Zhou X
    Med Sci Monit; 2016 May; 22():1694-701. PubMed ID: 27198165
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ventilators for noninvasive ventilation to treat acute respiratory failure.
    Scala R; Naldi M
    Respir Care; 2008 Aug; 53(8):1054-80. PubMed ID: 18655744
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of Reported Tidal Volume During Neonatal Ventilation With Airway Leak: A Lung Model Study.
    Moon K; Takeuchi M; Tachibana K; Mizuguchi S; Hirano S
    Pediatr Crit Care Med; 2019 Jan; 20(1):e37-e45. PubMed ID: 30335665
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of noninvasive ventilation modes on ICU ventilators during pressure support: a bench model study.
    Vignaux L; Tassaux D; Jolliet P
    Intensive Care Med; 2007 Aug; 33(8):1444-51. PubMed ID: 17563875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Study of timing of invasive and noninvasive sequential ventilation in patients with acute respiratory distress syndrome].
    Wang X; Xu S; Liu G; Caikai S
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2014 May; 26(5):330-4. PubMed ID: 24809262
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A bench study of the effects of leak on ventilator performance during noninvasive ventilation.
    Ueno Y; Nakanishi N; Oto J; Imanaka H; Nishimura M
    Respir Care; 2011 Nov; 56(11):1758-64. PubMed ID: 21605483
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Noninvasive ventilation for acute respiratory failure.
    Hess DR
    Respir Care; 2013 Jun; 58(6):950-72. PubMed ID: 23709194
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patient-ventilator asynchrony during noninvasive ventilation: a bench and clinical study.
    Carteaux G; Lyazidi A; Cordoba-Izquierdo A; Vignaux L; Jolliet P; Thille AW; Richard JM; Brochard L
    Chest; 2012 Aug; 142(2):367-376. PubMed ID: 22406958
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.