These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 23697196)
1. [Endotracheal intubation for a neonatal patient complicated with Arnold-Chiari malformation using a Pentax airway scope with a neonatal-type INTLOCK blade (ITL-N)]. Hoshijima H; Takeuchi R; Imamura T; Iwase Y; Nagasaka H; Matsumoto N Masui; 2013 Apr; 62(4):435-8. PubMed ID: 23697196 [TBL] [Abstract][Full Text] [Related]
2. [Endotracheal intubation in an adult patient fitted with a Leksell frame using a Pentax Airwayscope with a pediatric-type INTLOCK blade (ITL-P)]. Takeuchi R; Hoshijima H; Horikoshi Y; Nakamura C; Iwase Y; Nagasaka H Masui; 2014 Aug; 63(8):881-3. PubMed ID: 25199322 [TBL] [Abstract][Full Text] [Related]
3. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. Hirabayashi Y; Seo N J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032 [TBL] [Abstract][Full Text] [Related]
4. A randomized comparison between the Pentax AWS video laryngoscope and the Macintosh laryngoscope in morbidly obese patients. Abdallah R; Galway U; You J; Kurz A; Sessler DI; Doyle DJ Anesth Analg; 2011 Nov; 113(5):1082-7. PubMed ID: 21918156 [TBL] [Abstract][Full Text] [Related]
5. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases. Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277 [TBL] [Abstract][Full Text] [Related]
6. Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial. Komasawa N; Ueki R; Kaminoh Y; Nishi S Am J Perinatol; 2015 Jul; 32(9):809-14. PubMed ID: 25594220 [TBL] [Abstract][Full Text] [Related]
7. Tracheal intubation with the PENTAX-AWS (airway scope) reduces changes of hemodynamic responses and bispectral index scores compared with the Macintosh laryngoscope. Nishikawa K; Matsuoka H; Saito S J Neurosurg Anesthesiol; 2009 Oct; 21(4):292-6. PubMed ID: 19955890 [TBL] [Abstract][Full Text] [Related]
8. Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model. Han SK; Shin DH; Choi PC Resuscitation; 2010 Jan; 81(1):69-73. PubMed ID: 19919888 [TBL] [Abstract][Full Text] [Related]
9. [Usability of modified INTLOCK for double-lumen endobronchial tube insertion with airway scope]. Nakamura R; Kusunoki S; Kawamoto M Masui; 2007 Jul; 56(7):817-9. PubMed ID: 17633843 [TBL] [Abstract][Full Text] [Related]
10. [Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope]. Ueshima H; Asai T; Shingu K; Inoue H; Hashimoto Y; Enomoto Y; Okuda Y Masui; 2008 Jan; 57(1):82-4. PubMed ID: 18214009 [TBL] [Abstract][Full Text] [Related]
11. [Pentax-AWS improves laryngeal view compared with Macintosh blade during laryngoscopy and facilitates easier intubation]. Suzuki A; Toyama Y; Katsumi N; Sasaki R; Hirota K; Matsumoto H; Takahata O; Iwasaki H Masui; 2007 Apr; 56(4):464-8. PubMed ID: 17441461 [TBL] [Abstract][Full Text] [Related]
12. [One case of the basilar invagination that prevented tracheal intubation by Airway Scope]. Kitai Y; Shizukuishi M; Fukuda I; Kazama T Masui; 2009 Nov; 58(11):1437-40. PubMed ID: 19928514 [TBL] [Abstract][Full Text] [Related]
13. Comparison of the Pentax-AWS airway scope with the Macintosh laryngoscope for nasotracheal intubation: a randomized, prospective study. Suzuki A; Onodera Y; Mitamura SM; Mamiya K; Kunisawa T; Takahata O; Henderson JJ; Iwasaki H J Clin Anesth; 2012 Nov; 24(7):561-5. PubMed ID: 23101771 [TBL] [Abstract][Full Text] [Related]
14. The Pentax-AWS video-laryngoscope: the first experience in one hundred patients. Asai T; Enomoto Y; Shimizu K; Shingu K; Okuda Y Anesth Analg; 2008 Jan; 106(1):257-9, table of contents. PubMed ID: 18165587 [TBL] [Abstract][Full Text] [Related]
16. Use of the Pentax-AWS in 293 patients with difficult airways. Asai T; Liu EH; Matsumoto S; Hirabayashi Y; Seo N; Suzuki A; Toi T; Yasumoto K; Okuda Y Anesthesiology; 2009 Apr; 110(4):898-904. PubMed ID: 19293707 [TBL] [Abstract][Full Text] [Related]
17. [Usability of AirWay Scope for awake tracheal intubation in a burn patient with difficult airway]. Kato T; Kusunoki S; Kawamoto M; Yuge O Masui; 2007 Oct; 56(10):1179-81. PubMed ID: 17966622 [TBL] [Abstract][Full Text] [Related]
18. Tracheal intubation of a difficult airway using Airway Scope, Airtraq, and Macintosh laryngoscope: a comparative manikin study of inexperienced personnel. Liu L; Tanigawa K; Kusunoki S; Tamura T; Ota K; Yamaga S; Kida Y; Otani T; Sadamori T; Takeda T; Iwasaki Y; Hirohashi N Anesth Analg; 2010 Apr; 110(4):1049-55. PubMed ID: 20357149 [TBL] [Abstract][Full Text] [Related]
19. A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when used by novice personnel: a manikin study. Malik MA; Hassett P; Carney J; Higgins BD; Harte BH; Laffey JG Can J Anaesth; 2009 Nov; 56(11):802-11. PubMed ID: 19655213 [TBL] [Abstract][Full Text] [Related]
20. Success rates and endotracheal tube insertion times of experienced emergency physicians using five video laryngoscopes: a randomised trial in a simulated trapped car accident victim. Wetsch WA; Carlitscheck M; Spelten O; Teschendorf P; Hellmich M; Genzwürker HV; Hinkelbein J Eur J Anaesthesiol; 2011 Dec; 28(12):849-58. PubMed ID: 21986981 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]