BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 23706903)

  • 21. Long-Term Management of Vascular Access Ports in Nonhuman Primates Used in Preclinical Efficacy and Tolerability Studies.
    Mutch LA; Klinker ST; Janecek JJ; Niewinski MN; M Z Lee R; Graham ML
    J Invest Surg; 2020 Jul; 33(6):493-504. PubMed ID: 30543131
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Subcutaneous cannula in the jugular and femoral vein--a tool for frequent blood sampling and infusions in the rat.
    Bodziony J; Schwille PO
    Z Versuchstierkd; 1985; 27(1):29-32. PubMed ID: 3993249
    [No Abstract]   [Full Text] [Related]  

  • 23. Use of subcutaneous vascular access ports in rhesus monkeys.
    Wojnicki FH; Bacher JD; Glowa JR
    Lab Anim Sci; 1994 Oct; 44(5):491-4. PubMed ID: 7844959
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of coagulation test results for blood samples obtained by means of direct venipuncture and through a jugular vein catheter in clinically normal dogs.
    Millis DL; Hawkins E; Jager M; Boyle CR
    J Am Vet Med Assoc; 1995 Nov; 207(10):1311-4. PubMed ID: 7591925
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Chronic central vein catheterization for intraoperative and long-term venous access in swine.
    Moritz MW; Dawe EJ; Holliday JF; Elliott S; Mattei JA; Thomas AL
    Lab Anim Sci; 1989 Mar; 39(2):153-5. PubMed ID: 2709806
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A surgical procedure and tethering system for chronic blood sampling, infusion, and temperature monitoring in caged nonhuman primates.
    McNamee GA; Wannemacher RW; Dinterman RE; Rozmiarek H; Montrey RD
    Lab Anim Sci; 1984 Jun; 34(3):303-7. PubMed ID: 6748610
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Insertion and management of long-term central venous devices: role of radiologic imaging techniques].
    Capaccioli L; Nistri M; Distante V; Rontini M; Manetti A; Stecco A
    Radiol Med; 1998 Oct; 96(4):369-74. PubMed ID: 9972217
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A jugular bleeding technique in rabbits.
    Nelson EA; Keller GL; Mitchell TW; Pennypacker B; Rebbeck P; Rogers IT
    Lab Anim (NY); 2010 Jan; 39(1):17-22. PubMed ID: 20023677
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A novel alternative placement site and technique for totally implantable vascular access ports in non-human primates.
    Graham ML; Rieke EF; Dunning M; Mutch LA; Craig AM; Zolondek EK; Hering BJ; Schuurman HJ; Bianco RW
    J Med Primatol; 2009 Jun; 38(3):204-12. PubMed ID: 19220683
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Temporary hemodialysis catheters as a long-term vascular access in chronic hemodialysis patients.
    Ponikvar R; Buturović-Ponikvar J
    Ther Apher Dial; 2005 Jun; 9(3):250-3. PubMed ID: 15967000
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Modified procedure for implantation of subcutaneous central venous access devices in macaques (Macaca mulatta).
    Nuchtern J; McGuffey L; Durfee J; Dauser R; Blaney SM
    Comp Med; 2000 Oct; 50(5):486-9. PubMed ID: 11099129
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of covalently bound heparin coating on patency and biocompatibility of long-term indwelling catheters in the rat jugular vein.
    Foley PL; Barthel CH; Brausa HR
    Comp Med; 2002 Jun; 52(3):243-8. PubMed ID: 12102570
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Technique for implantation of chronic indwelling aortic access catheters.
    Bartoli CR; Okabe K; Akiyama I; Verrier RL; Godleski JJ
    J Invest Surg; 2006; 19(6):397-405. PubMed ID: 17101609
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
    Kovac J; Buturović-Ponikvar J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Permanent intravenous access in experimental surgery – our experience.
    Pálek R; Rosendorf J; Šarčevič S; Ševčík J; Brzoň O; Kepková L; Krystl P; Brousil M; Červenková L; Třeška V; Liška V
    Rozhl Chir; 2022; 101(12):577-583. PubMed ID: 36759204
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Complications associated with use of subcutaneous vascular access ports in cats and dogs undergoing fractionated radiotherapy: 172 cases (1996-2007).
    Culp WT; Mayhew PD; Reese MS; Duda L; Glassman MM; Brown DC
    J Am Vet Med Assoc; 2010 Jun; 236(12):1322-7. PubMed ID: 20550447
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Prospective evaluation of complications associated with jugular venous catheter use in a veterinary hospital.
    Adamantos S; Brodbelt D; Moores AL
    J Small Anim Pract; 2010 May; 51(5):254-7. PubMed ID: 20402840
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Simple cannulation procedure for serial blood sampling through cutaneous ulnar vein in chickens.
    Bayer DM; Mohan K; Jayakumar K; Manafi M; Pavithra BH
    J Appl Anim Welf Sci; 2012; 15(1):91-100. PubMed ID: 22233218
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Use of large-bore catheters in the internal jugular vein as an access route for emergency hemodialysis.
    Bambauer R; Jutzler GA
    Neth J Surg; 1983 Dec; 35(5):178-83. PubMed ID: 6657092
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A novel device for serial venous blood sampling in a canine model.
    Ollerenshaw JD; Schrøder M; Velschow S
    J Pharmacol Toxicol Methods; 2022; 114():107155. PubMed ID: 35038558
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.