149 related articles for article (PubMed ID: 23711503)
21. Accuracy of volumetric flow rate measurements: an in vitro study using modern ultrasound scanners.
Hoyt K; Hester FA; Bell RL; Lockhart ME; Robbin ML
J Ultrasound Med; 2009 Nov; 28(11):1511-8. PubMed ID: 19854966
[TBL] [Abstract][Full Text] [Related]
22. [Validation of a new hand-carried ultrasound device equipped with directional color power Doppler and continuous wave Doppler].
Kawai J; Tanabe K; Matsuzaki M; Yamaguchi K; Yagi T; Fujii Y; Konda T; Ui K; Sumida T; Okada M; Tani T; Morioka S
J Cardiol; 2003 Oct; 42(4):173-82. PubMed ID: 14598719
[TBL] [Abstract][Full Text] [Related]
23. Design of anthropomorphic flow phantoms based on rapid prototyping of compliant vessel geometries.
Lai SS; Yiu BY; Poon AK; Yu AC
Ultrasound Med Biol; 2013 Sep; 39(9):1654-64. PubMed ID: 23791354
[TBL] [Abstract][Full Text] [Related]
24. A rotating cylinder phantom for flow and tissue color Doppler testing.
Walker A; Henriksen E; Ringqvist I; Ask P
Ultrasound Med Biol; 2009 Nov; 35(11):1892-8. PubMed ID: 19713031
[TBL] [Abstract][Full Text] [Related]
25. Accurate blood peak velocity estimation using spectral models and vector doppler.
Ricci S; Vilkomerson D; Matera R; Tortoli P
IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Apr; 62(4):686-96. PubMed ID: 25881346
[TBL] [Abstract][Full Text] [Related]
26. Pulsed wave Doppler ultrasound: Accuracy, variability, and impact of acquisition parameters on flow measurements.
Russ MK; Lafata NM; Robertson SH; Samei E
Med Phys; 2023 Nov; 50(11):6704-6713. PubMed ID: 37793117
[TBL] [Abstract][Full Text] [Related]
27. Implementation of spectral width Doppler in pulsatile flow measurements.
Lee BR; Chiang HK; Chou YH; Kuo CD; Wang JH; Lee SK
Ultrasound Med Biol; 1999 Oct; 25(8):1221-7. PubMed ID: 10576265
[TBL] [Abstract][Full Text] [Related]
28. Inaccuracies in Measuring Velocities and Timing of Flow and Tissue Motion Using High-End Ultrasound Systems.
Walker AR; Uejima T; Prinz C; Voigt JU; Fraser AG
Ultrasound Med Biol; 2019 Jun; 45(6):1446-1454. PubMed ID: 30975534
[TBL] [Abstract][Full Text] [Related]
29. Lateral Position-Dependent Velocity Estimation Error in Plane-Wave Doppler Ultrasound Systems.
Wei L; Williams R; Loupas T; Helfield B; Burns PN
Ultrasound Med Biol; 2021 Aug; 47(8):2456-2466. PubMed ID: 34006440
[TBL] [Abstract][Full Text] [Related]
30. An improved spectral width Doppler method for estimating Doppler angles in flows with existence of velocity gradients.
Lee PL; Chou YH; Hsieh JC; Chiang HK
Ultrasound Med Biol; 2006 Aug; 32(8):1229-45. PubMed ID: 16875957
[TBL] [Abstract][Full Text] [Related]
31. Experimental characterization of a vector Doppler system based on a clinical ultrasound scanner.
Eranki A; Sikdar S
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2260-3. PubMed ID: 19965161
[TBL] [Abstract][Full Text] [Related]
32. Effects of beam steering in pulsed-wave ultrasound velocity estimation.
Steinman AH; Yu AC; Johnston KW; Cobbold RS
Ultrasound Med Biol; 2005 Aug; 31(8):1073-82. PubMed ID: 16085098
[TBL] [Abstract][Full Text] [Related]
33. A comparison of the imaging performance of high resolution ultrasound scanners for preclinical imaging.
Moran CM; Pye SD; Ellis W; Janeczko A; Morris KD; McNeilly AS; Fraser HM
Ultrasound Med Biol; 2011 Mar; 37(3):493-501. PubMed ID: 21256667
[TBL] [Abstract][Full Text] [Related]
34. An investigation of the relationship between ultrasound echo enhancement and Doppler frequency shift using a pulsatile arterial flow phantom.
Petrick J; Zomack M; Schlief R
Invest Radiol; 1997 Apr; 32(4):225-35. PubMed ID: 9101358
[TBL] [Abstract][Full Text] [Related]
35. Reducing registration error in cross-beam vector doppler imaging with position sensor.
Xu C; Beach KW; Leotta D; Stuzman E; Kim Y
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():495-8. PubMed ID: 19963465
[TBL] [Abstract][Full Text] [Related]
36. Combined 2-D Vector Velocity Imaging and Tracking Doppler for Improved Vascular Blood Velocity Quantification.
Avdal J; Lovstakken L; Torp H; Ekroll IK
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Dec; 64(12):1795-1804. PubMed ID: 28961109
[TBL] [Abstract][Full Text] [Related]
37. A rotating torus phantom for assessing color Doppler accuracy.
Stewart SF
Ultrasound Med Biol; 1999 Oct; 25(8):1251-64. PubMed ID: 10576268
[TBL] [Abstract][Full Text] [Related]
38. Vector-velocity estimation in swept-scan using a K-space approach.
Jeng GS; Li PC
IEEE Trans Ultrason Ferroelectr Freq Control; 2006 May; 53(5):947-58. PubMed ID: 16764449
[TBL] [Abstract][Full Text] [Related]
39. A comparison of single- and dual-beam methods for maximum velocity estimation.
Hoskins PR
Ultrasound Med Biol; 1999 May; 25(4):583-92. PubMed ID: 10386734
[TBL] [Abstract][Full Text] [Related]
40. Accuracy and reproducibility of a novel dual-beam vector Doppler method.
Ricci S; Diciotti S; Francalanci L; Tortoli P
Ultrasound Med Biol; 2009 May; 35(5):829-38. PubMed ID: 19110369
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]