BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

265 related articles for article (PubMed ID: 23711572)

  • 1. Development and validation of a liquid chromatography-tandem mass spectrometry method for simultaneous determination of amlodipine, atorvastatin and its metabolites ortho-hydroxy atorvastatin and para-hydroxy atorvastatin in human plasma and its application in a bioequivalence study.
    Zhou Y; Li J; He X; Jia M; Liu M; Li H; Xiong Z; Fan Y; Li W
    J Pharm Biomed Anal; 2013 Sep; 83():101-7. PubMed ID: 23711572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous determination of amlodipine and atorvastatin with its metabolites; ortho and para hydroxy atorvastatin; in human plasma by LC-MS/MS.
    Yacoub M; Awwad AA; Alawi M; Arafat T
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Feb; 917-918():36-47. PubMed ID: 23369879
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS).
    Macwan JS; Ionita IA; Dostalek M; Akhlaghi F
    Anal Bioanal Chem; 2011 Apr; 400(2):423-33. PubMed ID: 21359569
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-throughput salting-out-assisted liquid-liquid extraction for the simultaneous determination of atorvastatin, ortho-hydroxyatorvastatin, and para-hydroxyatorvastatin in human plasma using ultrafast liquid chromatography with tandem mass spectrometry.
    Yang Y; Xu Q; Zhou L; Zhong D; Chen X
    J Sep Sci; 2015 Mar; 38(6):1026-34. PubMed ID: 25581027
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative determination of atorvastatin and ortho-hydroxy atorvastatin in human plasma by liquid chromatography tandem mass spectrometry and pharmacokinetic evaluation.
    He BX; Shi L; Qiu J; Zeng XH; Tao L; Li R; Hong CJ; Gu XL; Dong FY; Yang L; Zhao SJ
    Methods Find Exp Clin Pharmacol; 2010 Sep; 32(7):481-7. PubMed ID: 21069099
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and validation of a high-performance liquid chromatography tandem mass spectrometry assay for atorvastatin, ortho-hydroxy atorvastatin, and para-hydroxy atorvastatin in human, dog, and rat plasma.
    Bullen WW; Miller RA; Hayes RN
    J Am Soc Mass Spectrom; 1999 Jan; 10(1):55-66. PubMed ID: 9888185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of roxatidine in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry: application to a bioequivalence study.
    Ryu JH; Choi SJ; Lee HW; Choi SK; Lee KT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Dec; 876(1):143-7. PubMed ID: 18977187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of atorvastatin and niacin in human plasma by LC-MS/MS and its application to a human pharmacokinetic study.
    Ravi VB; Mullangi R; Inamadugu JK; Pilli NR; Gajula R; Ponneri V
    Biomed Chromatogr; 2012 Nov; 26(11):1436-43. PubMed ID: 22415894
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous analysis of oxybutynin and its active metabolite N-desethyl oxybutynin in human plasma by stable isotope dilution LC-MS/MS to support a bioequivalence study.
    Sharma P; Patel DP; Sanyal M; Berawala H; Guttikar S; Shrivastav PS
    J Pharm Biomed Anal; 2013 Oct; 84():244-55. PubMed ID: 23867086
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous determination of atorvastatin, amlodipine, ramipril and benazepril in human plasma by LC-MS/MS and its application to a human pharmacokinetic study.
    Pilli NR; Inamadugu JK; Mullangi R; Karra VK; Vaidya JR; Rao JV
    Biomed Chromatogr; 2011 Apr; 25(4):439-49. PubMed ID: 20629042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a liquid chromatography/negative-ion electrospray tandem mass spectrometry assay for the determination of cilnidipine in human plasma and its application to a bioequivalence study.
    Lee HW; Seo JH; Lee HS; Jeong SY; Cho YW; Lee KT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 862(1-2):246-51. PubMed ID: 18155975
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of bevantolol in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry and its application to a bioequivalence study.
    Ren L; Wang Z; Lou Y; Zheng L; Zheng H; Yin C
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 May; 959():16-21. PubMed ID: 24747519
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous determination of amlodipine and bisoprolol in rat plasma by a liquid chromatography/tandem mass spectrometry method and its application in pharmacokinetic study.
    Chang H; Li J; Li J; Guan X; Sun F; Qian Z; Bi K; Fan G
    J Pharm Biomed Anal; 2012 Dec; 71():104-10. PubMed ID: 22947502
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Liquid chromatography-tandem mass spectrometry assay for the simultaneous quantification of simvastatin, lovastatin, atorvastatin, and their major metabolites in human plasma.
    Wang J; Luzum JA; Phelps MA; Kitzmiller JP
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Mar; 983-984():18-25. PubMed ID: 25612772
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous determination of metoprolol succinate and amlodipine besylate in human plasma by liquid chromatography-tandem mass spectrometry method and its application in bioequivalence study.
    Sarkar AK; Ghosh D; Das A; Selvan PS; Gowda KV; Mandal U; Bose A; Agarwal S; Bhaumik U; Pal TK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Sep; 873(1):77-85. PubMed ID: 18760977
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantification of amlodipine and atorvastatin in human plasma by UPLC-MS/MS method and its application to a bioequivalence study.
    Rezk MR; Badr KA
    Biomed Chromatogr; 2018 Jul; 32(7):e4224. PubMed ID: 29498757
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative determination of atorvastatin and para-hydroxy atorvastatin in human plasma by LC-MS-MS.
    Liu D; Jiang J; Zhou H; Hu P
    J Chromatogr Sci; 2008; 46(10):862-6. PubMed ID: 19007492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of xanthinol in human plasma and its application in a bioequivalence study of xanthinol nicotinate tablets.
    Liu HQ; Su MX; Di B; Hang TJ; Hu Y; Tian XQ; Zhang YD; Shen JP
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Sep; 873(1):20-6. PubMed ID: 18718822
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra-performance liquid chromatography/tandem mass spectrometry method for the determination of lercanidipine in human plasma.
    Kalovidouris M; Michalea S; Robola N; Koutsopoulou M; Panderi I
    Rapid Commun Mass Spectrom; 2006; 20(19):2939-46. PubMed ID: 16941725
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of lovastatin in human plasma by ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry.
    Wang D; Wang D; Qin F; Chen L; Li F
    Biomed Chromatogr; 2008 May; 22(5):511-8. PubMed ID: 18205133
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.