225 related articles for article (PubMed ID: 23714710)
1. First European multicenter results with a new transcutaneous bone conduction hearing implant system: short-term safety and efficacy.
Sprinzl G; Lenarz T; Ernst A; Hagen R; Wolf-Magele A; Mojallal H; Todt I; Mlynski R; Wolframm MD
Otol Neurotol; 2013 Aug; 34(6):1076-83. PubMed ID: 23714710
[TBL] [Abstract][Full Text] [Related]
2. A New Transcutaneous Bone Conduction Hearing Implant: Short-term Safety and Efficacy in Children.
Baumgartner WD; Hamzavi JS; Böheim K; Wolf-Magele A; Schlögel M; Riechelmann H; Zorowka P; Koci V; Keck T; Potzinger P; Sprinzl G
Otol Neurotol; 2016 Jul; 37(6):713-20. PubMed ID: 27153327
[TBL] [Abstract][Full Text] [Related]
3. Long-Term, Multicenter Results With the First Transcutaneous Bone Conduction Implant.
Sprinzl G; Lenarz T; Hagen R; Baumgartner WD; Keintzel T; Keck T; Riechelmann H; Magele A; Salcher R; Maier H; Mlynski R; Radeloff A; Rak K; Riss D; Liepins R; Hamzavi S; Rasse T; Potzinger P; Schmutzhard J; Zorowka P; Mittmann P; Böheim K; Todt I
Otol Neurotol; 2021 Jul; 42(6):858-866. PubMed ID: 33989254
[TBL] [Abstract][Full Text] [Related]
4. Retrospective Analysis of Hearing-Impaired Adult Patients Treated With an Active Transcutaneous Bone Conduction Implant.
Rader T; Stöver T; Lenarz T; Maier H; Zahnert T; Beleites T; Hagen R; Mlynski R; Baumgartner WD
Otol Neurotol; 2018 Aug; 39(7):874-881. PubMed ID: 29847467
[TBL] [Abstract][Full Text] [Related]
5. Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.
Schmerber S; Deguine O; Marx M; Van de Heyning P; Sterkers O; Mosnier I; Garin P; Godey B; Vincent C; Venail F; Mondain M; Deveze A; Lavieille JP; Karkas A
Eur Arch Otorhinolaryngol; 2017 Apr; 274(4):1835-1851. PubMed ID: 27475796
[TBL] [Abstract][Full Text] [Related]
6. Audiological and clinical outcomes of a transcutaneous bone conduction hearing implant: Six-month results from a multicentre study.
den Besten CA; Monksfield P; Bosman A; Skarzynski PH; Green K; Runge C; Wigren S; Blechert JI; Flynn MC; Mylanus EAM; Hol MKS
Clin Otolaryngol; 2019 Mar; 44(2):144-157. PubMed ID: 30358920
[TBL] [Abstract][Full Text] [Related]
7. Multicenter study with a direct acoustic cochlear implant.
Lenarz T; Zwartenkot JW; Stieger C; Schwab B; Mylanus EA; Caversaccio M; Kompis M; Snik AF; D'hondt C; Mojallal H
Otol Neurotol; 2013 Sep; 34(7):1215-25. PubMed ID: 23921930
[TBL] [Abstract][Full Text] [Related]
8. Hearing Benefit and Rated Satisfaction in Children with Unilateral Conductive Hearing Loss Using a Transcutaneous Magnetic-Coupled Bone-Conduction Hearing Aid.
Polonenko MJ; Carinci L; Gordon KA; Papsin BC; Cushing SL
J Am Acad Audiol; 2016; 27(10):790-804. PubMed ID: 27885975
[TBL] [Abstract][Full Text] [Related]
9. Preliminary functional results and quality of life after implantation of a new bone conduction hearing device in patients with conductive and mixed hearing loss.
Ihler F; Volbers L; Blum J; Matthias C; Canis M
Otol Neurotol; 2014 Feb; 35(2):211-5. PubMed ID: 24448279
[TBL] [Abstract][Full Text] [Related]
10. Multicentric study on surgical information and early safety and performance results with the Bonebridge BCI 602: an active transcutaneous bone conduction hearing implant.
Sprinzl G; Toner J; Koitschev A; Berger N; Keintzel T; Rasse T; Baumgartner WD; Honeder C; Magele A; Plontke S; Götze G; Schmutzhard J; Zelger P; Corkill S; Lenarz T; Salcher R
Eur Arch Otorhinolaryngol; 2023 Apr; 280(4):1565-1579. PubMed ID: 36625869
[TBL] [Abstract][Full Text] [Related]
11. Long-Term Outcomes of Vibroplasty Coupler Implantations to Treat Mixed/Conductive Hearing Loss.
Zahnert T; Mlynski R; Löwenheim H; Beutner D; Hagen R; Ernst A; Zehlicke T; Kühne H; Friese N; Tropitzsch A; Luers JC; Todt I; Hüttenbrink KB
Audiol Neurootol; 2018; 23(6):316-325. PubMed ID: 30650421
[TBL] [Abstract][Full Text] [Related]
12. Objective and subjective results of the Bonebridge transcutaneous active direct-drive bone conduction hearing implant.
Alzhrani F
Saudi Med J; 2019 Aug; 40(8):797-801. PubMed ID: 31423516
[TBL] [Abstract][Full Text] [Related]
13. A bone conduction implant using self-drilling screws : Self-drilling screws as a new fixation method of an active transcutaneous bone conduction hearing implant.
Koitschev A; Neudert M; Lenarz T
HNO; 2023 Aug; 71(Suppl 1):61-66. PubMed ID: 37322168
[TBL] [Abstract][Full Text] [Related]
14. Indication criteria and outcomes with the Bonebridge transcutaneous bone-conduction implant.
Riss D; Arnoldner C; Baumgartner WD; Blineder M; Flak S; Bachner A; Gstoettner W; Hamzavi JS
Laryngoscope; 2014 Dec; 124(12):2802-6. PubMed ID: 25142577
[TBL] [Abstract][Full Text] [Related]
15. Totally implantable active middle ear implant: Hearing and safety results in a large series.
Shohet JA; Gende DM; Tanita CS
Laryngoscope; 2018 Dec; 128(12):2872-2878. PubMed ID: 30194720
[TBL] [Abstract][Full Text] [Related]
16. Bonebridge transcutaneous bone conduction implant in children with congenital aural atresia: surgical and audiological outcomes.
Ngui LX; Tang IP
J Laryngol Otol; 2018 Aug; 132(8):693-697. PubMed ID: 30008276
[TBL] [Abstract][Full Text] [Related]
17. The Vibrant Soundbridge in Children and Adolescents: Preliminary European Multicenter Results.
Frenzel H; Sprinzl G; Streitberger C; Stark T; Wollenberg B; Wolf-Magele A; Giarbini N; Strenger T; Müller J; Hempel JM
Otol Neurotol; 2015 Aug; 36(7):1216-22. PubMed ID: 26107139
[TBL] [Abstract][Full Text] [Related]
18. Transcutaneous Baha Attract system: Long-term outcomes of the French multicenter study.
Nevoux J; Coudert C; Boulet M; Czajka C; Tavernier L; Daval M; Ayache D; Meller R; Rossetto S; Papon JF; Deveze A
Clin Otolaryngol; 2018 Dec; 43(6):1553-1559. PubMed ID: 30137669
[TBL] [Abstract][Full Text] [Related]
19. The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results.
Baumgartner WD; Böheim K; Hagen R; Müller J; Lenarz T; Reiss S; Schlögel M; Mlynski R; Mojallal H; Colletti V; Opie J
Adv Otorhinolaryngol; 2010; 69():38-50. PubMed ID: 20610913
[TBL] [Abstract][Full Text] [Related]
20. Long-term follow-up and review of the Bone Conduction Implant.
Reinfeldt S; Eeg-Olofsson M; Fredén Jansson KJ; Persson AC; Håkansson B
Hear Res; 2022 Aug; 421():108503. PubMed ID: 35490057
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]