These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 23718220)

  • 21. Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hematology analyzer.
    Kresie L; Benavides D; Bollinger P; Walters J; Pierson D; Richmond T; Issa-Dyer K; Fahs M
    Lab Hematol; 2005; 11(1):24-30. PubMed ID: 15790549
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Sysmex SE-9000 hematology analyzer: performance evaluation on leukocyte differential counts using an NCCLS H20-A protocol. National Committee for Clinical Laboratory Standards.
    Buttarello M; Bulian P; Temporin V; Rizzotti P
    Am J Clin Pathol; 1997 Dec; 108(6):674-86. PubMed ID: 9384450
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Automated analysis for differentiating leukocytes in body fluids using the software "biological liquid application" on ADVIA2120/2120i hematology analyzer.
    Falda A; Doretto P
    J Clin Lab Anal; 2018 Oct; 32(8):e22578. PubMed ID: 29802648
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Short communication: Evaluation of an automated method for assessing white blood cell concentrations in Holstein dairy cows.
    Kull JA; Krawczel PD; Pighetti GM
    Vet Immunol Immunopathol; 2018 Mar; 197():21-23. PubMed ID: 29475502
    [TBL] [Abstract][Full Text] [Related]  

  • 25. UF-1000i: validation of the body fluid mode for counting cells in body fluids.
    Fleming C; Brouwer R; van Alphen A; Lindemans J; de Jonge R
    Clin Chem Lab Med; 2014 Dec; 52(12):1781-90. PubMed ID: 24964259
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the accuracy of the diff3/50 with a cell by cell comparison.
    Cembrowski GS; Wilson MK; Adelmeyer SG; Chang CK
    Am J Clin Pathol; 1983 Sep; 80(3):333-41. PubMed ID: 6881097
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids.
    de Jonge R; Brouwer R; de Graaf MT; Luitwieler RL; Fleming C; de Frankrijker-Merkestijn M; Sillevis Smitt PA; Boonstra JG; Lindemans J
    Clin Chem Lab Med; 2010 May; 48(5):665-75. PubMed ID: 20187854
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Elimination of interference by lipids in the low WBC mode in the automated hematology analyzer XN-2000.
    Tanaka Y; Matsushita H; Tanaka Y; Maruki Y; Hayashi F; Kondo T; Asai S; Miyachi H
    Int J Lab Hematol; 2014 Aug; 36(4):e50-4. PubMed ID: 24262035
    [No Abstract]   [Full Text] [Related]  

  • 29. Comparison of the Cytodiff flow cytometric leucocyte differential count system with the Sysmex XE-2100 and Beckman Coulter UniCel DxH 800.
    Park BG; Park CJ; Kim S; Yoon CH; Kim DH; Jang S; Chi HS
    Int J Lab Hematol; 2012 Dec; 34(6):584-93. PubMed ID: 22709133
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Performance evaluation of the new hematology analyzer Sysmex XN-series.
    Seo JY; Lee ST; Kim SH
    Int J Lab Hematol; 2015 Apr; 37(2):155-64. PubMed ID: 24815300
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance evaluation of the digital cell imaging analyzer DI-60 integrated into the fully automated Sysmex XN hematology analyzer system.
    Tabe Y; Yamamoto T; Maenou I; Nakai R; Idei M; Horii T; Miida T; Ohsaka A
    Clin Chem Lab Med; 2015 Feb; 53(2):281-9. PubMed ID: 25153399
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of high-fluorescence body fluid (HF-BF) parameter as a screening tool of malignancy in body fluids.
    Rastogi L; Dass J; Arya V; Kotwal J
    Indian J Pathol Microbiol; 2019; 62(4):572-577. PubMed ID: 31611442
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Short-term biological variation of differential count in healthy subjects in a South Asian population.
    Gupta AK; Kunnumbrath A; Tayal SG; Mehan A; Sahay R; Kumar U; Jeladharan R; Anthony ML; Singh N; Chandra H; Chowdhury N
    Scand J Clin Lab Invest; 2020 Dec; 80(8):654-658. PubMed ID: 33016776
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analytic performance of the PENTRA 80 automated blood cell analyzer for the evaluation of normal and pathologic WBCs.
    Arroyo ME; Tabernero MD; García-Marcos MA; Orfao A
    Am J Clin Pathol; 2005 Feb; 123(2):206-14. PubMed ID: 15842044
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Automated
    Dumas C; Bienvenu AL; Girard S; Picot S; Debize G; Durand B
    J Clin Pathol; 2018 Jul; 71(7):594-599. PubMed ID: 29298814
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance of Abbott Alinity hq hematology analyzer for automated cell counting of body fluids.
    Herroelen PH; Demeester S; Damiaens S; Evenepoel A; Jochmans K
    Int J Lab Hematol; 2022 Feb; 44(1):96-103. PubMed ID: 34582122
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others).
    Aulesa C; Mainar I; Prieto M; Cobos N; Galimany R
    Lab Hematol; 2003; 9(4):214-24. PubMed ID: 14649464
    [TBL] [Abstract][Full Text] [Related]  

  • 38. False negative results for eosinophils in the 00-19E (Build 5) Information Processing Unit version of automated hematology analyzer sysmex XN series.
    Shen Y; Lu Q; Chen R; Yang X; Zhang H; Lu C
    Scand J Clin Lab Invest; 2019; 79(1-2):126-128. PubMed ID: 30600719
    [No Abstract]   [Full Text] [Related]  

  • 39. Performance Evaluation of Body Fluid Cellular Analysis Using the Beckman Coulter UniCel DxH 800, Sysmex XN-350, and UF-5000 Automated Cellular Analyzers.
    Cho J; Oh J; Lee SG; Lee YH; Song J; Kim JH
    Ann Lab Med; 2020 Mar; 40(2):122-130. PubMed ID: 31650728
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of automated slidemakers and stainers in a working laboratory environment - routine operation and quality control.
    Simson E; Gascon-Lema MG; Brown DL
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 1):e64-76. PubMed ID: 19220552
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.