These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
333 related articles for article (PubMed ID: 23718601)
1. Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer. Crosbie JC; Rogers PA; Stevenson AW; Hall CJ; Lye JE; Nordström T; Midgley SM; Lewis RA Med Phys; 2013 Jun; 40(6):062103. PubMed ID: 23718601 [TBL] [Abstract][Full Text] [Related]
2. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter. Harty PD; Lye JE; Ramanathan G; Butler DJ; Hall CJ; Stevenson AW; Johnston PN Med Phys; 2014 May; 41(5):052101. PubMed ID: 24784390 [TBL] [Abstract][Full Text] [Related]
3. Energy spectra considerations for synchrotron radiotherapy trials on the ID17 bio-medical beamline at the European Synchrotron Radiation Facility. Crosbie JC; Fournier P; Bartzsch S; Donzelli M; Cornelius I; Stevenson AW; Requardt H; Bräuer-Krisch E J Synchrotron Radiat; 2015 Jul; 22(4):1035-41. PubMed ID: 26134808 [TBL] [Abstract][Full Text] [Related]
4. Quantitative characterization of the X-ray beam at the Australian Synchrotron Imaging and Medical Beamline (IMBL). Stevenson AW; Crosbie JC; Hall CJ; Häusermann D; Livingstone J; Lye JE J Synchrotron Radiat; 2017 Jan; 24(Pt 1):110-141. PubMed ID: 28009552 [TBL] [Abstract][Full Text] [Related]
5. Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields. Livingstone J; Stevenson AW; Butler DJ; Häusermann D; Adam JF Med Phys; 2016 Jul; 43(7):4283. PubMed ID: 27370143 [TBL] [Abstract][Full Text] [Related]
6. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co. Snow JR; Micka JA; DeWerd LA Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881 [TBL] [Abstract][Full Text] [Related]
7. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers. Lye JE; Harty PD; Butler DJ; Crosbie JC; Livingstone J; Poole CM; Ramanathan G; Wright T; Stevenson AW Phys Med Biol; 2016 Jun; 61(11):4201-22. PubMed ID: 27192396 [TBL] [Abstract][Full Text] [Related]
8. Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy. Martínez-Rovira I; Sempau J; Prezado Y Med Phys; 2012 Jan; 39(1):119-31. PubMed ID: 22225281 [TBL] [Abstract][Full Text] [Related]
9. Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: machine-specific, plan-class, and clinical fields. Gago-Arias A; Rodriguez-Romero R; Sanchez-Rubio P; Miguel Gonzalez-Castano D; Gomez F; Nunez L; Palmans H; Sharpe P; Pardo-Montero J Med Phys; 2012 Apr; 39(4):1964-70. PubMed ID: 22482617 [TBL] [Abstract][Full Text] [Related]
11. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. Capote R; Sánchez-Doblado F; Leal A; Lagares JI; Arráns R; Hartmann GH Med Phys; 2004 Sep; 31(9):2416-22. PubMed ID: 15487721 [TBL] [Abstract][Full Text] [Related]
12. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry. Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221 [TBL] [Abstract][Full Text] [Related]
13. Ion recombination in parallel-plate free-air ionization chambers for synchrotron radiation. Nariyama N Phys Med Biol; 2006 Oct; 51(20):5199-209. PubMed ID: 17019033 [TBL] [Abstract][Full Text] [Related]
14. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy. Hiatt JR; Rivard MJ; Hughes HG Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699 [TBL] [Abstract][Full Text] [Related]
15. Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations. Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K Med Phys; 2012 Dec; 39(12):7462-9. PubMed ID: 23231295 [TBL] [Abstract][Full Text] [Related]
16. Ion recombination for ionization chamber dosimetry in a helical tomotherapy unit. Palmans H; Thomas RA; Duane S; Sterpin E; Vynckier S Med Phys; 2010 Jun; 37(6):2876-89. PubMed ID: 20632599 [TBL] [Abstract][Full Text] [Related]
17. CT dosimetry at the Australian Synchrotron for 25-100 keV photons and 35-160 mm-diameter biological specimens. Midgley S; Schleich N; Merchant A; Stevenson A J Synchrotron Radiat; 2019 Mar; 26(Pt 2):517-527. PubMed ID: 30855263 [TBL] [Abstract][Full Text] [Related]
18. Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER. Chu CH; Kuan WP; Kurosawa T; Lin UT; Chen IJ; Chen WL Radiat Prot Dosimetry; 2010 Feb; 138(2):99-106. PubMed ID: 19789201 [TBL] [Abstract][Full Text] [Related]
20. The effect of spectra on calibration and measurement with mammographic ionization chambers. DeWerd LA; Micka JA; Laird RW; Pearson DW; O'Brien M; Lamperti P Med Phys; 2002 Nov; 29(11):2649-54. PubMed ID: 12462732 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]