These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 23720378)

  • 1. Very late stent thrombosis related to incomplete neointimal coverage or neoatherosclerotic plaque rupture identified by optical coherence tomography imaging.
    Amabile N; Souteyrand G; Ghostine S; Combaret N; Slama MS; Barber-Chamoux N; Motreff P; Caussin C
    Eur Heart J Cardiovasc Imaging; 2014 Jan; 15(1):24-31. PubMed ID: 23720378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Optical coherence tomographic analysis of in-stent neoatherosclerosis in lesions with restenosis after drug-eluting stent implantation].
    Liu ZJ; Shi B; Deng CC; Xu GX; Zhao RZ; Shen CY; Wang ZL; Liu HL
    Zhonghua Xin Xue Guan Bing Za Zhi; 2018 Jan; 46(1):44-49. PubMed ID: 29374937
    [No Abstract]   [Full Text] [Related]  

  • 3. Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium).
    Joner M; Koppara T; Byrne RA; Castellanos MI; Lewerich J; Novotny J; Guagliumi G; Xhepa E; Adriaenssens T; Godschalk TC; Malik N; Alfonso F; Tada T; Neumann FJ; Desmet W; Ten Berg JM; Gershlick AH; Feldman LJ; Massberg S; Kastrati A;
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1340-1350. PubMed ID: 30025727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation.
    Ko YG; Kim DM; Cho JM; Choi SY; Yoon JH; Kim JS; Kim BK; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2012 Apr; 28(4):715-23. PubMed ID: 21656060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. OCT analysis in patients with very late stent thrombosis.
    Kang SJ; Lee CW; Song H; Ahn JM; Kim WJ; Lee JY; Park DW; Lee SW; Kim YH; Mintz GS; Park SW; Park SJ
    JACC Cardiovasc Imaging; 2013 Jun; 6(6):695-703. PubMed ID: 23643282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Failure Mechanisms and Neoatherosclerosis Patterns in Very Late Drug-Eluting and Bare-Metal Stent Thrombosis.
    Nakamura D; Attizzani GF; Toma C; Sheth T; Wang W; Soud M; Aoun R; Tummala R; Leygerman M; Fares A; Mehanna E; Nishino S; Fung A; Costa MA; Bezerra HG
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27582113
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: an optical coherence tomography study.
    Davlouros PA; Nikokiris G; Karantalis V; Mavronasiou E; Xanthopoulou I; Damelou A; Tsigkas G; Alexopoulos D
    Int J Cardiol; 2011 Sep; 151(2):155-9. PubMed ID: 20605242
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characteristics of Earlier Versus Delayed Presentation of Very Late Drug-Eluting Stent Thrombosis: An Optical Coherence Tomographic Study.
    Lee SY; Ahn JM; Mintz GS; Hur SH; Choi SY; Kim SW; Cho JM; Hong SJ; Kim JW; Hong YJ; Lee SG; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Park SJ; Hong MK
    J Am Heart Assoc; 2017 Apr; 6(4):. PubMed ID: 28411245
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanisms of stent thrombosis analysed by optical coherence tomography: insights from the national PESTO French registry.
    Souteyrand G; Amabile N; Mangin L; Chabin X; Meneveau N; Cayla G; Vanzetto G; Barnay P; Trouillet C; Rioufol G; Rangé G; Teiger E; Delaunay R; Dubreuil O; Lhermusier T; Mulliez A; Levesque S; Belle L; Caussin C; Motreff P;
    Eur Heart J; 2016 Apr; 37(15):1208-16. PubMed ID: 26757787
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo optical coherence tomography of very late drug-eluting stent thrombosis compared with late in-stent restenosis.
    Miyazaki S; Hiasa Y; Takahashi T; Yano Y; Minami T; Murakami N; Mizobe M; Tobetto Y; Nakagawa T; Chen PM; Ogura R; Miyajima H; Yuba K; Hosokawa S; Kishi K; Ohtani R
    Circ J; 2012; 76(2):390-8. PubMed ID: 22130319
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [OCT analysis of in-stent neointima over 5 years post-DES implantation].
    Han Y; Yuan XH; Jiang MT; Feng HH; Zhang X; Zhang YQ; Jing J; Chen YD; Gao L
    Zhonghua Xin Xue Guan Bing Za Zhi; 2024 Feb; 52(2):150-157. PubMed ID: 38326066
    [No Abstract]   [Full Text] [Related]  

  • 12. An Optical Coherence Tomography Assessment of Stent Strut Apposition Based on the Presence of Lipid-Rich Plaque in the Carotid Artery.
    Liu R; Jiang Y; Xiong Y; Li M; Ma M; Zhu W; Yin Q; Li W; Xu G; Liu X
    J Endovasc Ther; 2015 Dec; 22(6):942-9. PubMed ID: 26464412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study.
    Chieffo A; Buchanan GL; Parodi G; Versaci F; Bianchi RM; Valenti R; Saccà S; Mongiardo A; Span S; Migliorini A; Spaccarotella C; Reimers B; Antoniucci D; Indolfi C; Ferrari A; Maehara A; Mintz GS; Colombo A
    EuroIntervention; 2014 Dec; 10(8):916-23. PubMed ID: 24974806
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship between non-culprit lesion plaque characteristics changes and in-stent neoatherosclerosis formation: 1-year follow-up optical coherence tomography study.
    Xing L; Zou Y; Fu C; Fan X; Wang X; Liu Q; Yang M; Liu D; Feng L; Hou J; Huang X
    Rev Cardiovasc Med; 2021 Dec; 22(4):1693-1700. PubMed ID: 34957812
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tissue coverage of paclitaxel and sirolimus eluting stents in long term follow-up: optical coherence tomography study.
    Kochman J; Pietrasik A; Rdzanek A; Ścibisz A; Pawlak M; Filipiak KJ; Opolski G
    Cardiol J; 2013; 20(3):247-53. PubMed ID: 23788298
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correlation between pre-procedural plaque morphology and patterns of in-stent neointimal hyperplasia at 1-year follow-up in patients treated with new-generation drug-eluting stents: An optical coherence tomography based analysis.
    Shi SY; Chen KL; Gu J; Xu C; Chen QR; Chen YQ; Xu T; Ke HY; Sun JH; Ye F
    J Interv Cardiol; 2018 Dec; 31(6):737-746. PubMed ID: 30251273
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.
    Kang SJ; Mintz GS; Akasaka T; Park DW; Lee JY; Kim WJ; Lee SW; Kim YH; Whan Lee C; Park SW; Park SJ
    Circulation; 2011 Jun; 123(25):2954-63. PubMed ID: 21646494
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography.
    Li S; Gai L; Yang T; Zhang L; Xu X; Bai Q; Xu H; Wang Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):768-75. PubMed ID: 22639418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of baseline plaque characteristic on the development of neoatherosclerosis in the very late phase after stenting.
    Hoshino M; Yonetsu T; Kanaji Y; Usui E; Yamaguchi M; Hada M; Hamaya R; Kanno Y; Murai T; Lee T; Kakuta T
    J Cardiol; 2019 Jul; 74(1):67-73. PubMed ID: 30733110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography.
    Kim S; Kim JS; Shin DH; Kim BK; Ko YG; Choi D; Cho YK; Nam CW; Hur SH; Jang Y; Hong MK
    Am J Cardiol; 2013 Jan; 111(1):1-5. PubMed ID: 23040589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.