These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 2372568)

  • 1. [Inductive stimulation].
    Eichhorn KF; Arndt B; Claus D; Heinrich W; Sembach O; Schreivogel K
    Biomed Tech (Berl); 1990 Jun; 35(6):139-44. PubMed ID: 2372568
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetic stimulators.
    J Clin Neurophysiol; 1991 Jan; 8(1):121-9. PubMed ID: 2019647
    [No Abstract]   [Full Text] [Related]  

  • 3. Frequency-related effects in the optimization of coils for the magnetic stimulation of the nervous system.
    Ravazzani P; Ruohonen J; Tognola G; Anfosso F; Ollikainen M; Ilmoniemi RJ; Grandori F
    IEEE Trans Biomed Eng; 2002 May; 49(5):463-71. PubMed ID: 12002178
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrical stimulation and electrode properties. Part 1: clinical electrodes.
    Stevenson M; Baylor K; Netherton BL; Stecker MM
    Am J Electroneurodiagnostic Technol; 2010 Sep; 50(3):171-86. PubMed ID: 20957973
    [No Abstract]   [Full Text] [Related]  

  • 5. Toroidal coil models for transcutaneous magnetic stimulation of nerves.
    Carbunaru R; Durand DM
    IEEE Trans Biomed Eng; 2001 Apr; 48(4):434-41. PubMed ID: 11322531
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel electric design for electromagnetic stimulation--the Slinky coil.
    Ren C; Tarjan PP; Popović DB
    IEEE Trans Biomed Eng; 1995 Sep; 42(9):918-25. PubMed ID: 7558066
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An introduction to the basic principles of magnetic nerve stimulation.
    Barker AT
    J Clin Neurophysiol; 1991 Jan; 8(1):26-37. PubMed ID: 2019648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multichannel magnetic stimulation system design considering mutual couplings among the stimulation coils.
    Han BH; Chun IK; Lee SC; Lee SY
    IEEE Trans Biomed Eng; 2004 May; 51(5):812-7. PubMed ID: 15132507
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A project of magnetic coils newly designed to restrain the negative value of the intensity of magnetic induced electric field].
    Liu Z; Yin T; Guan X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):45-8, 59. PubMed ID: 12744160
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo 3-D distributions of electric fields in pig skin with rectangular pulse electrical current stimulation (RPECS).
    Cheng K; Tarjan PP; Thio YC; Mertz PM
    Bioelectromagnetics; 1996; 17(4):253-62. PubMed ID: 8891184
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The role of magnetic stimulation in diagnosis of the peripheral nervous system].
    Dressler D; Benecke R; Meyer BU; Conrad B
    EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1988 Dec; 19(4):260-3. PubMed ID: 2850154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neural stimulation and recording electrodes.
    Cogan SF
    Annu Rev Biomed Eng; 2008; 10():275-309. PubMed ID: 18429704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Transcranial cortex stimulation with magnetic field pulses: methodologic and physiologic principles].
    Hess CW; Ludin HP
    EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1988 Dec; 19(4):209-15. PubMed ID: 3145181
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing magnetic stimulator design.
    Cadwell J
    Electroencephalogr Clin Neurophysiol Suppl; 1991; 43():238-48. PubMed ID: 1773761
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Design of a half solenoid coil for optimization of magnetic focusing in trans-cranial magnetic stimulation].
    Hu W; Wang X; Yang Y; Liang D; Zhao F
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):910-3. PubMed ID: 17899772
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Current distribution under electrodes in relation to stimulation current and skin blood flow: are modern electrodes really providing the current distribution during stimulation we believe they are?
    Petrofsky J; Schwab E; Cúneo M; George J; Kim J; Almalty A; Lawson D; Johnson E; Remigo W
    J Med Eng Technol; 2006; 30(6):368-81. PubMed ID: 17060165
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Developing a more focal magnetic stimulator. Part II: Fabricating coils and measuring induced current distributions.
    Yunokuchi K; Cohen D
    J Clin Neurophysiol; 1991 Jan; 8(1):112-20. PubMed ID: 2019646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Improvement of coils used in functional magnetic stimulation].
    Wang Y; Shen Q; Jiang D
    Space Med Med Eng (Beijing); 2001 Aug; 14(4):261-3. PubMed ID: 11681338
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Magnetic coil design considerations for functional magnetic stimulation.
    Lin VW; Hsiao IN; Dhaka V
    IEEE Trans Biomed Eng; 2000 May; 47(5):600-10. PubMed ID: 10851804
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electromagnetic stimulation of the auditory system: effects and side-effects.
    Counter SA
    Scand Audiol Suppl; 1993; 37():1-32. PubMed ID: 8210963
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.