These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 23742540)

  • 1. Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms.
    Prasad R; Abicht F; Borghesi M; Braenzel J; Nickles PV; Priebe G; Schnürer M; Ter-Avetisyan S
    Rev Sci Instrum; 2013 May; 84(5):053302. PubMed ID: 23742540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Absolute response of a proton detector composed of a microchannel plate assembly and a charge-coupled device to laser-accelerated multi-MeV protons.
    Mahmood MA; Ahn GE; Lee SH; Kim SY; Ahmad I; Tahir S; Yang JM; Yoon JW; Sung JH; Lee SK; Choi IW; Nam CH
    Rev Sci Instrum; 2022 Nov; 93(11):113311. PubMed ID: 36461536
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies.
    Jeong TW; Singh PK; Scullion C; Ahmed H; Kakolee KF; Hadjisolomou P; Alejo A; Kar S; Borghesi M; Ter-Avetisyan S
    Rev Sci Instrum; 2016 Aug; 87(8):083301. PubMed ID: 27587107
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles.
    Freeman CG; Fiksel G; Stoeckl C; Sinenian N; Canfield MJ; Graeper GB; Lombardo AT; Stillman CR; Padalino SJ; Mileham C; Sangster TC; Frenje JA
    Rev Sci Instrum; 2011 Jul; 82(7):073301. PubMed ID: 21806176
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions.
    Harres K; Schollmeier M; Brambrink E; Audebert P; Blazević A; Flippo K; Gautier DC; Geissel M; Hegelich BM; Nürnberg F; Schreiber J; Wahl H; Roth M
    Rev Sci Instrum; 2008 Sep; 79(9):093306. PubMed ID: 19044406
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of micro-channel plate detector in a Thomson spectrometer for protons and carbon ions with energies below 1 MeV.
    Varmazyar P; Singh PK; Elekes Z; Halasz Z; Nagy B; Son JG; Csontos J; Mohacsi A; Nelissen K; Somoskői T; Szabo RE; Toth S; Ter-Avetisyan S; Osvay K
    Rev Sci Instrum; 2022 Jul; 93(7):073301. PubMed ID: 35922328
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calibration of BAS-TR image plate response to high energy (3-300 MeV) carbon ions.
    Doria D; Kar S; Ahmed H; Alejo A; Fernandez J; Cerchez M; Gray RJ; Hanton F; MacLellan DA; McKenna P; Najmudin Z; Neely D; Romagnani L; Ruiz JA; Sarri G; Scullion C; Streeter M; Swantusch M; Willi O; Zepf M; Borghesi M
    Rev Sci Instrum; 2015 Dec; 86(12):123302. PubMed ID: 26724017
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thomson parabola and time-of-flight detector cross-calibration methodology on the ALLS 100 TW laser-driven ion acceleration beamline.
    Vallières S; Salvadori M; Puyuelo-Valdes P; Payeur S; Fourmaux S; Consoli F; Verona C; d'Humières E; Chicoine M; Roorda S; Schiettekatte F; Antici P
    Rev Sci Instrum; 2020 Oct; 91(10):103303. PubMed ID: 33138598
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions.
    Choi IW; Kim CM; Sung JH; Yu TJ; Lee SK; Kim IJ; Jin YY; Jeong TM; Hafz N; Pae KH; Noh YC; Ko DK; Yogo A; Pirozhkov AS; Ogura K; Orimo S; Sagisaka A; Nishiuchi M; Daito I; Oishi Y; Iwashita Y; Nakamura S; Nemoto K; Noda A; Daido H; Lee J
    Rev Sci Instrum; 2009 May; 80(5):053302. PubMed ID: 19485501
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Angular-Resolved Thomson Parabola Spectrometer for Laser-Driven Ion Accelerators.
    Salgado-López C; Apiñaniz JI; Henares JL; Pérez-Hernández JA; de Luis D; Volpe L; Gatti G
    Sensors (Basel); 2022 Apr; 22(9):. PubMed ID: 35590929
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gamma-ray detection efficiency of the microchannel plate installed as an ion detector in the low energy particle instrument onboard the GEOTAIL satellite.
    Tanaka YT; Yoshikawa I; Yoshioka K; Terasawa T; Saito Y; Mukai T
    Rev Sci Instrum; 2007 Mar; 78(3):034501. PubMed ID: 17411203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Absolute calibration of Fujifilm BAS-TR image plate response to laser driven protons up to 40 MeV.
    Martin P; Ahmed H; Doria D; Alejo A; Clarke R; Ferguson S; Fernández-Tobias J; Freeman RR; Fuchs J; Green A; Green JS; Gwynne D; Hanton F; Jarrett J; Jung D; Kakolee KF; Krygier AG; Lewis CLS; McIlvenny A; McKenna P; Morrison JT; Najmudin Z; Naughton K; Nersisyan G; Norreys P; Notley M; Roth M; Ruiz JA; Scullion C; Zepf M; Zhai S; Borghesi M; Kar S
    Rev Sci Instrum; 2022 May; 93(5):053303. PubMed ID: 35649771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Operating a triple stack microchannel plate-phosphor assembly for single particle counting in the 12-300 K temperature range.
    Rosén S; Schmidt HT; Reinhed P; Fischer D; Thomas RD; Cederquist H; Liljeby L; Bagge L; Leontein S; Blom M
    Rev Sci Instrum; 2007 Nov; 78(11):113301. PubMed ID: 18052467
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a single-shot-imaging thin film for an online Thomson parabola spectrometer.
    Sakaki H; Kanasaki M; Fukuda Y; Nishiuchi M; Hori T; Yogo A; Jinno S; Niita K
    Rev Sci Instrum; 2013 Jan; 84(1):013301. PubMed ID: 23387636
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers.
    Alejo A; Kar S; Ahmed H; Krygier AG; Doria D; Clarke R; Fernandez J; Freeman RR; Fuchs J; Green A; Green JS; Jung D; Kleinschmidt A; Lewis CL; Morrison JT; Najmudin Z; Nakamura H; Nersisyan G; Norreys P; Notley M; Oliver M; Roth M; Ruiz JA; Vassura L; Zepf M; Borghesi M
    Rev Sci Instrum; 2014 Sep; 85(9):093303. PubMed ID: 25273715
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a high resolution and high dispersion Thomson parabola.
    Jung D; Hörlein R; Kiefer D; Letzring S; Gautier DC; Schramm U; Hübsch C; Öhm R; Albright BJ; Fernandez JC; Habs D; Hegelich BM
    Rev Sci Instrum; 2011 Jan; 82(1):013306. PubMed ID: 21280824
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Absolute response of a Fuji BAS-TR imaging plate to low-energy protons (<0.2 MeV) and carbon ions (<1 MeV).
    Kojima S; Miyatake T; Inoue S; Dinh TH; Hasegawa N; Mori M; Sakaki H; Nishiuchi M; Dover NP; Yamamoto Y; Sasaki T; Ito F; Kondo K; Yamanaka T; Hashida M; Sakabe S; Nishikino M; Kondo K
    Rev Sci Instrum; 2021 Mar; 92(3):033306. PubMed ID: 33820038
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of the low-energy channel Thomson parabola of the LMJ-PETAL diagnostic SEPAGE with protons and carbon ions.
    Ducret JE; Batani D; Boutoux G; Chancé A; Gastineau B; Guillard JC; Harrault F; Jakubowska K; Lantuejoul-Thfoin I; Leboeuf D; Loiseau D; Lotode A; Pès C; Rabhi N; Saïd A; Semsoum A; Serani L; Thomas B; Toussaint JC; Vauzour B
    Rev Sci Instrum; 2018 Feb; 89(2):023304. PubMed ID: 29495838
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration of a microchannel plate based extreme ultraviolet grazing incident spectrometer at the Advanced Light Source.
    Bakeman MS; van Tilborg J; Sokollik T; Baum D; Ybarrolaza N; Duarte R; Toth C; Leemans WP
    Rev Sci Instrum; 2010 Oct; 81(10):10E313. PubMed ID: 21034012
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection efficiency of microchannel plates for e(-) and π(-) in the momentum range from 17.5 to 345 MeV/c.
    Tulej M; Meyer S; Lüthi M; Lasi D; Galli A; Desorgher L; Hajdas W; Karlsson S; Kalla L; Wurz P
    Rev Sci Instrum; 2015 Aug; 86(8):083310. PubMed ID: 26329184
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.