188 related articles for article (PubMed ID: 23748600)
1. The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.
Sotomi Y; Iwakura K; Higuchi Y; Abe K; Yoshida J; Masai T; Fujii K
J Clin Monit Comput; 2013 Dec; 27(6):639-46. PubMed ID: 23748600
[TBL] [Abstract][Full Text] [Related]
2. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values.
Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y
J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325
[TBL] [Abstract][Full Text] [Related]
3. The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation.
Suehiro K; Tanaka K; Yamada T; Matsuura T; Mori T; Funao T; Nishikawa K
J Clin Monit Comput; 2015 Jun; 29(3):333-9. PubMed ID: 25212705
[TBL] [Abstract][Full Text] [Related]
4. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes.
Suehiro K; Tanaka K; Funao T; Matsuura T; Mori T; Nishikawa K
Br J Anaesth; 2013 Aug; 111(2):170-7. PubMed ID: 23479677
[TBL] [Abstract][Full Text] [Related]
5. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery.
Lu JK; Zhu C; Jing H; Wang YJ; Qing EM
Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136
[TBL] [Abstract][Full Text] [Related]
6. Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy.
Metzelder S; Coburn M; Fries M; Reinges M; Reich S; Rossaint R; Marx G; Rex S
Br J Anaesth; 2011 Jun; 106(6):776-84. PubMed ID: 21441548
[TBL] [Abstract][Full Text] [Related]
7. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter.
Lamia B; Kim HK; Severyn DA; Pinsky MR
J Clin Monit Comput; 2018 Feb; 32(1):33-43. PubMed ID: 28188408
[TBL] [Abstract][Full Text] [Related]
8. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes.
Suehiro K; Tanaka K; Mikawa M; Uchihara Y; Matsuyama T; Matsuura T; Funao T; Yamada T; Mori T; Nishikawa K
J Cardiothorac Vasc Anesth; 2015; 29(3):656-62. PubMed ID: 25440654
[TBL] [Abstract][Full Text] [Related]
9. Inaccuracy of the FloTrac/Vigileo™ system in patients with low cardiac index.
Maeda T; Yoshitani K; Inatomi Y; Ohnishi Y
J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1521-6. PubMed ID: 25306519
[TBL] [Abstract][Full Text] [Related]
10. Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.
Maeda T; Hattori K; Sumiyoshi M; Kanazawa H; Ohnishi Y
J Anesth; 2018 Jun; 32(3):387-393. PubMed ID: 29616345
[TBL] [Abstract][Full Text] [Related]
11. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.
Manecke GR; Auger WR
J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472
[TBL] [Abstract][Full Text] [Related]
12. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters.
Hadian M; Kim HK; Severyn DA; Pinsky MR
Crit Care; 2010; 14(6):R212. PubMed ID: 21092290
[TBL] [Abstract][Full Text] [Related]
13. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage.
Junttila EK; Koskenkari JK; Ohtonen PP; Ala-Kokko TI
Br J Anaesth; 2011 Oct; 107(4):581-6. PubMed ID: 21693470
[TBL] [Abstract][Full Text] [Related]
14. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
Biais M; Nouette-Gaulain K; Cottenceau V; Vallet A; Cochard JF; Revel P; Sztark F
Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863
[TBL] [Abstract][Full Text] [Related]
15. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.
Wagner JY; Körner A; Schulte-Uentrop L; Kubik M; Reichenspurner H; Kluge S; Reuter DA; Saugel B
J Clin Monit Comput; 2018 Apr; 32(2):235-244. PubMed ID: 28540614
[TBL] [Abstract][Full Text] [Related]
16. Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device.
Su BC; Tsai YF; Chen CY; Yu HP; Yang MW; Lee WC; Lin CC
Transplant Proc; 2012 Mar; 44(2):424-8. PubMed ID: 22410034
[TBL] [Abstract][Full Text] [Related]
17. Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.
Lee M; Weinberg L; Pearce B; Scurrah N; Story DA; Pillai P; McCall PR; P McNicol L; Peyton PJ
J Clin Monit Comput; 2017 Apr; 31(2):343-351. PubMed ID: 26884378
[TBL] [Abstract][Full Text] [Related]
18. Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.
Slagt C; de Leeuw MA; Beute J; Rijnsburger E; Hoeksema M; Mulder JW; Malagon I; Groeneveld AB
J Clin Monit Comput; 2013 Apr; 27(2):171-7. PubMed ID: 23154918
[TBL] [Abstract][Full Text] [Related]
19. Accuracy of Cardiac Output Measured by Fourth-Generation FloTrac and LiDCOrapid, and Their Characteristics Regarding Systemic Vascular Resistance in Patients Undergoing Cardiac Surgery.
Takei Y; Kumagai M; Suzuki M; Mori S; Sato Y; Tamii T; Tamii A; Saito A; Ogata Y; Kaiho Y; Toyama H; Ejima Y; Yamauchi M
J Cardiothorac Vasc Anesth; 2023 Jul; 37(7):1143-1151. PubMed ID: 37076386
[TBL] [Abstract][Full Text] [Related]
20. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements.
Cannesson M; Attof Y; Rosamel P; Joseph P; Bastien O; Lehot JJ
Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]