149 related articles for article (PubMed ID: 23751209)
1. Recording low and high spatial frequencies in exit wave reconstructions.
Haigh SJ; Jiang B; Alloyeau D; Kisielowski C; Kirkland AI
Ultramicroscopy; 2013 Oct; 133():26-34. PubMed ID: 23751209
[TBL] [Abstract][Full Text] [Related]
2. Optimal tilt magnitude determination for aberration-corrected super resolution exit wave function reconstruction.
Haigh SJ; Sawada H; Kirkland AI
Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3755-71. PubMed ID: 19687064
[TBL] [Abstract][Full Text] [Related]
3. Exit wave reconstructions using through focus series of HREM images.
Zandbergen HW; Van Dyck D
Microsc Res Tech; 2000 May; 49(3):301-23. PubMed ID: 10816270
[TBL] [Abstract][Full Text] [Related]
4. A flux-preserving non-linear inline holography reconstruction algorithm for partially coherent electrons.
Koch CT
Ultramicroscopy; 2008 Jan; 108(2):141-50. PubMed ID: 17485172
[TBL] [Abstract][Full Text] [Related]
5. Theoretical aspects of image formation in the aberration-corrected electron microscope.
Rose H
Ultramicroscopy; 2010 Apr; 110(5):488-99. PubMed ID: 19896274
[TBL] [Abstract][Full Text] [Related]
6. "Indirect" high-resolution transmission electron microscopy: aberration measurement and wavefunction reconstruction.
Kirkland AI; Meyer RR
Microsc Microanal; 2004 Aug; 10(4):401-13. PubMed ID: 15327700
[TBL] [Abstract][Full Text] [Related]
7. Exit wave reconstruction at atomic resolution.
Allen LJ; McBride W; O'Leary NL; Oxley MP
Ultramicroscopy; 2004 Jul; 100(1-2):91-104. PubMed ID: 15219694
[TBL] [Abstract][Full Text] [Related]
8. Aberration-corrected microscopy for structural biology applications.
Ziegler A; Rockel B; Hegerl R; Freitag B; Lücken U; Plitzko JM
J Microsc; 2009 Jan; 233(1):170-7. PubMed ID: 19196423
[TBL] [Abstract][Full Text] [Related]
9. Optimized conditions for imaging the effects of bonding charge density in electron microscopy.
Ciston J; Kim JS; Haigh SJ; Kirkland AI; Marks LD
Ultramicroscopy; 2011 Jun; 111(7):901-11. PubMed ID: 21193268
[TBL] [Abstract][Full Text] [Related]
10. Using a monochromator to improve the resolution in TEM to below 0.5 Å. Part II: application to focal series reconstruction.
Tiemeijer PC; Bischoff M; Freitag B; Kisielowski C
Ultramicroscopy; 2012 Jul; 118():35-43. PubMed ID: 22728403
[TBL] [Abstract][Full Text] [Related]
11. High precision measurements of atom column positions using model-based exit wave reconstruction.
De Backer A; Van Aert S; Van Dyck D
Ultramicroscopy; 2011; 111(9-10):1475-82. PubMed ID: 21930019
[TBL] [Abstract][Full Text] [Related]
12. Assessing the benefits of focal pair cryo-electron tomography.
Kudryashev M; Stahlberg H; Castaño-Díez D
J Struct Biol; 2012 May; 178(2):88-97. PubMed ID: 22056466
[TBL] [Abstract][Full Text] [Related]
13. Practical image restoration of thick biological specimens using multiple focus levels in transmission electron microscopy.
Han KF; Sedat JW; Agard DA
J Struct Biol; 1997 Dec; 120(3):237-44. PubMed ID: 9441929
[TBL] [Abstract][Full Text] [Related]
14. The wrap-around problem and optimal padding in the exit wave reconstruction using HRTEM images.
Lin F; Chen FR; Chen Q; Tang D; Peng LM
J Electron Microsc (Tokyo); 2006 Aug; 55(4):191-200. PubMed ID: 17050589
[TBL] [Abstract][Full Text] [Related]
15. Electron holography with a Cs-corrected transmission electron microscope.
Geiger D; Lichte H; Linck M; Lehmann M
Microsc Microanal; 2008 Feb; 14(1):68-81. PubMed ID: 18096096
[TBL] [Abstract][Full Text] [Related]
16. Improved Zernike-type phase contrast for transmission electron microscopy.
Koeck PJ
J Microsc; 2015 Jul; 259(1):74-8. PubMed ID: 25865092
[TBL] [Abstract][Full Text] [Related]
17. Combining real and reciprocal space information for aberration free coherent electron diffractive imaging.
Zuo JM; Zhang J; Huang W; Ran K; Jiang B
Ultramicroscopy; 2011 Jun; 111(7):817-23. PubMed ID: 21159441
[TBL] [Abstract][Full Text] [Related]
18. Effective phase correction function for high-resolution exit wave reconstruction by a three-dimensional Fourier filtering method.
Kawasaki T; Taya M; Nomaguchi T; Takai Y
Ultramicroscopy; 2005 Jan; 102(2):127-39. PubMed ID: 15590136
[TBL] [Abstract][Full Text] [Related]
19. Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.
Van Aert S; Chen JH; Van Dyck D
Ultramicroscopy; 2010 Oct; 110(11):1404-10. PubMed ID: 20655146
[TBL] [Abstract][Full Text] [Related]
20. Improved specimen reconstruction by Hilbert phase contrast tomography.
Barton B; Joos F; Schröder RR
J Struct Biol; 2008 Nov; 164(2):210-20. PubMed ID: 18725304
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]