134 related articles for article (PubMed ID: 23752352)
1. Quantification of tumor necrosis factor-α and matrix metalloproteinases-3 in synovial fluid by a fiber-optic particle plasmon resonance sensor.
Huang YC; Chiang CY; Li CH; Chang TC; Chiang CS; Chau LK; Huang KW; Wu CW; Wang SC; Lyu SR
Analyst; 2013 Aug; 138(16):4599-606. PubMed ID: 23752352
[TBL] [Abstract][Full Text] [Related]
2. Fiber-optic particle plasmon resonance sensor for detection of interleukin-1β in synovial fluids.
Chiang CY; Hsieh ML; Huang KW; Chau LK; Chang CM; Lyu SR
Biosens Bioelectron; 2010 Nov; 26(3):1036-42. PubMed ID: 20833017
[TBL] [Abstract][Full Text] [Related]
3. Direct detection of orchid viruses using nanorod-based fiber optic particle plasmon resonance immunosensor.
Lin HY; Huang CH; Lu SH; Kuo IT; Chau LK
Biosens Bioelectron; 2014 Jan; 51():371-8. PubMed ID: 24001513
[TBL] [Abstract][Full Text] [Related]
4. Integration of fiber optic-particle plasmon resonance biosensor with microfluidic chip.
Hsu WT; Hsieh WH; Cheng SF; Jen CP; Wu CC; Li CH; Lee CY; Li WY; Chau LK; Chiang CY; Lyu SR
Anal Chim Acta; 2011 Jul; 697(1-2):75-82. PubMed ID: 21641421
[TBL] [Abstract][Full Text] [Related]
5. Novel U-bent fiber optic probe for localized surface plasmon resonance based biosensor.
Sai VV; Kundu T; Mukherji S
Biosens Bioelectron; 2009 May; 24(9):2804-9. PubMed ID: 19285853
[TBL] [Abstract][Full Text] [Related]
6. Serum and knee synovial fluid matrix metalloproteinase-13 and tumor necrosis factor-alpha levels in patients with late-stage osteoarthritis.
Özler K; Aktaş E; Atay Ç; Yılmaz B; Arıkan M; Güngör Ş
Acta Orthop Traumatol Turc; 2016; 50(3):356-61. PubMed ID: 27130394
[TBL] [Abstract][Full Text] [Related]
7. Metalloproteinases and tumor necrosis factor-alpha activities in synovial fluids of horses: correlation with articular cartilage alterations.
Jouglin M; Robert C; Valette JP; Gavard F; Quintin-Colonna F; Denoix JM
Vet Res; 2000; 31(5):507-15. PubMed ID: 11050746
[TBL] [Abstract][Full Text] [Related]
8. Using a fiber optic particle plasmon resonance biosensor to determine kinetic constants of antigen-antibody binding reaction.
Chang TC; Wu CC; Wang SC; Chau LK; Hsieh WH
Anal Chem; 2013 Jan; 85(1):245-50. PubMed ID: 23186304
[TBL] [Abstract][Full Text] [Related]
9. Matrix metalloproteinases MMP-3 and MMP-1 levels in sera and synovial fluids in patients with rheumatoid arthritis and osteoarthritis.
Mahmoud RK; El-Ansary AK; El-Eishi HH; Kamal HM; El-Saeed NH
Ital J Biochem; 2005; 54(3-4):248-57. PubMed ID: 16688934
[TBL] [Abstract][Full Text] [Related]
10. Multiple resonance fiber-optic sensor with time division multiplexing for multianalyte detection.
Lin HY; Huang CH; Huang CC; Liu YC; Chau LK
Opt Lett; 2012 Oct; 37(19):3969-71. PubMed ID: 23027248
[TBL] [Abstract][Full Text] [Related]
11. Dual-channel fiber surface plasmon resonance biological sensor based on a hybrid interrogation of intensity and wavelength modulation.
Li L; Zhang X; Liang Y; Guang J; Peng W
J Biomed Opt; 2016 Dec; 21(12):127001. PubMed ID: 27930775
[TBL] [Abstract][Full Text] [Related]
12. MutS protein-based fiber optic particle plasmon resonance biosensor for detecting single nucleotide polymorphisms.
Ngo LT; Wang WK; Tseng YT; Chang TC; Kuo PL; Chau LK; Huang TT
Anal Bioanal Chem; 2021 May; 413(12):3329-3337. PubMed ID: 33712917
[TBL] [Abstract][Full Text] [Related]
13. Fiber Optic Particle Plasmon Resonance-Based Immunoassay Using a Novel Multi-Microchannel Biochip.
Chiang CY; Chen CH; Wang CT
Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32485995
[TBL] [Abstract][Full Text] [Related]
14. Fiber Optic Particle Plasmon Resonance Biosensor for Label-Free Detection of Nucleic Acids and Its Application to HLA-B27 mRNA Detection in Patients with Ankylosing Spondylitis.
Tseng YT; Li WY; Yu YW; Chiang CY; Liu SQ; Chau LK; Lai NS; Chou CC
Sensors (Basel); 2020 Jun; 20(11):. PubMed ID: 32492975
[TBL] [Abstract][Full Text] [Related]
15. Surface plasmon resonance immunoassay for the detection of the TNFα biomarker in human serum.
Martinez-Perdiguero J; Retolaza A; Bujanda L; Merino S
Talanta; 2014 Feb; 119():492-7. PubMed ID: 24401446
[TBL] [Abstract][Full Text] [Related]
16. Matrix metalloproteinases and tissue inhibitors of metalloproteinases in synovial fluids of patients with temporomandibular joint osteoarthritis.
Kanyama M; Kuboki T; Kojima S; Fujisawa T; Hattori T; Takigawa M; Yamashita A
J Orofac Pain; 2000; 14(1):20-30. PubMed ID: 11203734
[TBL] [Abstract][Full Text] [Related]
17. Optical fiber surface plasmon resonance sensor using electroless-plated gold film for thrombin detection.
Huang Y; Pu X; Qian H; Chuang CJ; Dong S; Wu J; Xue J; Cheng W; Ding S; Li S
Anal Bioanal Chem; 2024 Mar; 416(6):1469-1483. PubMed ID: 38236393
[TBL] [Abstract][Full Text] [Related]
18. Self-referencing fiber optic particle plasmon resonance sensing system for real-time biological monitoring.
Wu CW; Chiang CY; Chen CH; Chiang CS; Wang CT; Chau LK
Talanta; 2016; 146():291-8. PubMed ID: 26695266
[TBL] [Abstract][Full Text] [Related]
19. Detection of antinuclear antibodies by a colloidal gold modified optical fiber: comparison with ELISA.
Lai NS; Wang CC; Chiang HL; Chau LK
Anal Bioanal Chem; 2007 Jun; 388(4):901-7. PubMed ID: 17476484
[TBL] [Abstract][Full Text] [Related]
20. Localized surface plasmon coupled fluorescence fiber-optic biosensor with gold nanoparticles.
Hsieh BY; Chang YF; Ng MY; Liu WC; Lin CH; Wu HT; Chou C
Anal Chem; 2007 May; 79(9):3487-93. PubMed ID: 17378542
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]