BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 23752352)

  • 1. Quantification of tumor necrosis factor-α and matrix metalloproteinases-3 in synovial fluid by a fiber-optic particle plasmon resonance sensor.
    Huang YC; Chiang CY; Li CH; Chang TC; Chiang CS; Chau LK; Huang KW; Wu CW; Wang SC; Lyu SR
    Analyst; 2013 Aug; 138(16):4599-606. PubMed ID: 23752352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fiber-optic particle plasmon resonance sensor for detection of interleukin-1β in synovial fluids.
    Chiang CY; Hsieh ML; Huang KW; Chau LK; Chang CM; Lyu SR
    Biosens Bioelectron; 2010 Nov; 26(3):1036-42. PubMed ID: 20833017
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct detection of orchid viruses using nanorod-based fiber optic particle plasmon resonance immunosensor.
    Lin HY; Huang CH; Lu SH; Kuo IT; Chau LK
    Biosens Bioelectron; 2014 Jan; 51():371-8. PubMed ID: 24001513
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Integration of fiber optic-particle plasmon resonance biosensor with microfluidic chip.
    Hsu WT; Hsieh WH; Cheng SF; Jen CP; Wu CC; Li CH; Lee CY; Li WY; Chau LK; Chiang CY; Lyu SR
    Anal Chim Acta; 2011 Jul; 697(1-2):75-82. PubMed ID: 21641421
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel U-bent fiber optic probe for localized surface plasmon resonance based biosensor.
    Sai VV; Kundu T; Mukherji S
    Biosens Bioelectron; 2009 May; 24(9):2804-9. PubMed ID: 19285853
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Serum and knee synovial fluid matrix metalloproteinase-13 and tumor necrosis factor-alpha levels in patients with late-stage osteoarthritis.
    Özler K; Aktaş E; Atay Ç; Yılmaz B; Arıkan M; Güngör Ş
    Acta Orthop Traumatol Turc; 2016; 50(3):356-61. PubMed ID: 27130394
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Metalloproteinases and tumor necrosis factor-alpha activities in synovial fluids of horses: correlation with articular cartilage alterations.
    Jouglin M; Robert C; Valette JP; Gavard F; Quintin-Colonna F; Denoix JM
    Vet Res; 2000; 31(5):507-15. PubMed ID: 11050746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using a fiber optic particle plasmon resonance biosensor to determine kinetic constants of antigen-antibody binding reaction.
    Chang TC; Wu CC; Wang SC; Chau LK; Hsieh WH
    Anal Chem; 2013 Jan; 85(1):245-50. PubMed ID: 23186304
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Matrix metalloproteinases MMP-3 and MMP-1 levels in sera and synovial fluids in patients with rheumatoid arthritis and osteoarthritis.
    Mahmoud RK; El-Ansary AK; El-Eishi HH; Kamal HM; El-Saeed NH
    Ital J Biochem; 2005; 54(3-4):248-57. PubMed ID: 16688934
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multiple resonance fiber-optic sensor with time division multiplexing for multianalyte detection.
    Lin HY; Huang CH; Huang CC; Liu YC; Chau LK
    Opt Lett; 2012 Oct; 37(19):3969-71. PubMed ID: 23027248
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dual-channel fiber surface plasmon resonance biological sensor based on a hybrid interrogation of intensity and wavelength modulation.
    Li L; Zhang X; Liang Y; Guang J; Peng W
    J Biomed Opt; 2016 Dec; 21(12):127001. PubMed ID: 27930775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MutS protein-based fiber optic particle plasmon resonance biosensor for detecting single nucleotide polymorphisms.
    Ngo LT; Wang WK; Tseng YT; Chang TC; Kuo PL; Chau LK; Huang TT
    Anal Bioanal Chem; 2021 May; 413(12):3329-3337. PubMed ID: 33712917
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fiber Optic Particle Plasmon Resonance-Based Immunoassay Using a Novel Multi-Microchannel Biochip.
    Chiang CY; Chen CH; Wang CT
    Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32485995
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fiber Optic Particle Plasmon Resonance Biosensor for Label-Free Detection of Nucleic Acids and Its Application to HLA-B27 mRNA Detection in Patients with Ankylosing Spondylitis.
    Tseng YT; Li WY; Yu YW; Chiang CY; Liu SQ; Chau LK; Lai NS; Chou CC
    Sensors (Basel); 2020 Jun; 20(11):. PubMed ID: 32492975
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surface plasmon resonance immunoassay for the detection of the TNFα biomarker in human serum.
    Martinez-Perdiguero J; Retolaza A; Bujanda L; Merino S
    Talanta; 2014 Feb; 119():492-7. PubMed ID: 24401446
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Matrix metalloproteinases and tissue inhibitors of metalloproteinases in synovial fluids of patients with temporomandibular joint osteoarthritis.
    Kanyama M; Kuboki T; Kojima S; Fujisawa T; Hattori T; Takigawa M; Yamashita A
    J Orofac Pain; 2000; 14(1):20-30. PubMed ID: 11203734
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical fiber surface plasmon resonance sensor using electroless-plated gold film for thrombin detection.
    Huang Y; Pu X; Qian H; Chuang CJ; Dong S; Wu J; Xue J; Cheng W; Ding S; Li S
    Anal Bioanal Chem; 2024 Mar; 416(6):1469-1483. PubMed ID: 38236393
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Self-referencing fiber optic particle plasmon resonance sensing system for real-time biological monitoring.
    Wu CW; Chiang CY; Chen CH; Chiang CS; Wang CT; Chau LK
    Talanta; 2016; 146():291-8. PubMed ID: 26695266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of antinuclear antibodies by a colloidal gold modified optical fiber: comparison with ELISA.
    Lai NS; Wang CC; Chiang HL; Chau LK
    Anal Bioanal Chem; 2007 Jun; 388(4):901-7. PubMed ID: 17476484
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Localized surface plasmon coupled fluorescence fiber-optic biosensor with gold nanoparticles.
    Hsieh BY; Chang YF; Ng MY; Liu WC; Lin CH; Wu HT; Chou C
    Anal Chem; 2007 May; 79(9):3487-93. PubMed ID: 17378542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.