These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 23756497)

  • 1. Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance.
    Guillot M; Gingras L; Archambault L; Beddar S; Beaulieu L
    Phys Med Biol; 2013 Jul; 58(13):4439-54. PubMed ID: 23756497
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. IMRT quality assurance using a second treatment planning system.
    Anjum MN; Parker W; Ruo R; Aldahlawi I; Afzal M
    Med Dosim; 2010; 35(4):274-9. PubMed ID: 19944590
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.
    Gagnon JC; Thériault D; Guillot M; Archambault L; Beddar S; Gingras L; Beaulieu L
    Med Phys; 2012 Jan; 39(1):429-36. PubMed ID: 22225313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning.
    Yang Y; Xing L
    Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An oscillating sweeping gap test for VMAT quality assurance.
    Bhagwat MS; Han Z; Ng SK; Zygmanski P
    Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy.
    Bayouth JE
    Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S93-7. PubMed ID: 18406947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
    Baker SJ; Budgell GJ; MacKay RI
    Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MLC quality assurance techniques for IMRT applications.
    Bayouth JE; Wendt D; Morrill SM
    Med Phys; 2003 May; 30(5):743-50. PubMed ID: 12772980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach.
    Wiezorek T; Banz N; Schwedas M; Scheithauer M; Salz H; Georg D; Wendt TG
    Strahlenther Onkol; 2005 Jul; 181(7):468-74. PubMed ID: 15995841
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma.
    Bai S; Li G; Wang M; Jiang Q; Zhang Y; Wei Y
    Med Dosim; 2013; 38(2):143-7. PubMed ID: 23402928
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V output.
    Agnew CE; King RB; Hounsell AR; McGarry CK
    Phys Med Biol; 2012 Nov; 57(21):6761-77. PubMed ID: 23032423
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a novel ArcCHECK(™) insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities.
    Fakir H; Gaede S; Mulligan M; Chen JZ
    Med Phys; 2012 Jul; 39(7):4203-8. PubMed ID: 22830753
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer.
    Kim Y; Verhey LJ; Xia P
    Phys Med Biol; 2007 Apr; 52(8):2147-56. PubMed ID: 17404460
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance.
    Yewondwossen M
    Med Dosim; 2012; 37(3):250-6. PubMed ID: 22189031
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Patient-related quality assurance with different combinations of treatment planning systems, techniques, and machines : A multi-institutional survey.
    Steiniger B; Berger R; Eilzer S; Kornhuber C; Lorenz K; Peil T; Reiffenstuhl C; Schilz J; Schröder D; Schwedas M; Pensold S; Walke M; Weibert K; Wolf U; Wiezorek T
    Strahlenther Onkol; 2017 Jan; 193(1):46-54. PubMed ID: 27812732
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance.
    Olch AJ; Whitaker ML
    Med Phys; 2010 Aug; 37(8):4485-94. PubMed ID: 20879607
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development and characterization of a tissue equivalent plastic scintillator based dosimetry system.
    Petric MP; Robar JL; Clark BG
    Med Phys; 2006 Jan; 33(1):96-105. PubMed ID: 16485414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An improvement in IMRT QA results and beam matching in linacs using statistical process control.
    Gagneur JD; Ezzell GA
    J Appl Clin Med Phys; 2014 Sep; 15(5):4927. PubMed ID: 25207579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the ArcCHECK QA system for IMRT and VMAT verification.
    Li G; Zhang Y; Jiang X; Bai S; Peng G; Wu K; Jiang Q
    Phys Med; 2013 May; 29(3):295-303. PubMed ID: 22583979
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.