These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

293 related articles for article (PubMed ID: 23760118)

  • 21. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study.
    Sungur M; Karakurt C; Ozbarlas N; Baspinar O
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):245-52. PubMed ID: 23460349
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.
    Wang JK; Wu MH; Lin MT; Chiu SN; Chen CA; Chiu HH
    Circ J; 2010 Feb; 74(2):361-4. PubMed ID: 20032563
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Safety of transcatheter patent ductus arteriosus closure in small weight infants.
    Drighil A; Al Jufan M; Al Omrane K; Al Atta J; Al Omrani A; Al Fadley F
    J Interv Cardiol; 2012 Aug; 25(4):391-4. PubMed ID: 22574623
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Closure of the patent ductus arteriosus with the new duct occluder II additional sizes device.
    Agnoletti G; Marini D; Villar AM; Bordese R; Gabbarini F
    Catheter Cardiovasc Interv; 2012 Jun; 79(7):1169-74. PubMed ID: 22422478
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II].
    Parra-Bravo JR; Osuna-Izaguirre MA; Beirana-Palencia L; Gálvez-Cancino F; Martínez-Monterrosas C; Lazo-Cárdenas C; Reyes-Vargas C
    Arch Cardiol Mex; 2014; 84(3):171-6. PubMed ID: 24998666
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Trans-catheter closure of patent ductus arteriosus-What is the best device?
    Ghasemi A; Pandya S; Reddy SV; Turner DR; Du W; Navabi MA; Mirzaaghayan MR; Kiani A; Sloan K; Forbes TJ
    Catheter Cardiovasc Interv; 2010 Nov; 76(5):687-95. PubMed ID: 20815044
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results.
    Sinha SK; Razi M; Pandey RN; Kumar P; Krishna V; Jha MJ; Mishra V; Asif M; Abdali N; Tewari P; Thakur R; Pandey U; Varma CM
    Anatol J Cardiol; 2017 Nov; 18(5):321-327. PubMed ID: 29145233
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder.
    García-Montes JA; Camacho-Castro A; Sandoval-Jones JP; Buendía-Hernández A; Calderón-Colmenero J; Patiño-Bahena E; Zabal C
    Cardiol Young; 2015 Mar; 25(3):491-5. PubMed ID: 24555910
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A follow-up study on transcatheter closure of patent ductus arteriosus with Amplatzer duct occluder in children].
    Li JJ; Li YF; Zhang ZW; Qian MY; Wang HS
    Zhonghua Er Ke Za Zhi; 2005 Aug; 43(8):608-11. PubMed ID: 16191275
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Surgical rescue of embolized amplatzer devices.
    Amanullah MM; Siddiqui MT; Khan MZ; Atiq MA
    J Card Surg; 2011 May; 26(3):254-8. PubMed ID: 21480992
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.
    Bilici M; Demir F; Akın A; Türe M; Balık H; Kuyumcu M
    Pediatr Cardiol; 2017 Dec; 38(8):1598-1605. PubMed ID: 28828684
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical evaluation of the new Amplatzer duct occluder II for patent arterial duct occlusion.
    Bhole V; Miller P; Mehta C; Stumper O; Reinhardt Z; De Giovanni JV
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):762-9. PubMed ID: 19522000
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Amplatzer Duct Occluder II Additional Sizes device for transcatheter PDA closure: initial experience.
    Bruckheimer E; Godfrey M; Dagan T; Levinzon M; Amir G; Birk E
    Catheter Cardiovasc Interv; 2014 Jun; 83(7):1097-101. PubMed ID: 24532416
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Patent ductus arteriosus endovascular closure by amplatzer duct occluder.
    Khelashvili V; Gogorishili I; Metreveli I; Tsintsadze A; Botsvadze T
    Georgian Med News; 2006 May; (134):19-22. PubMed ID: 16783056
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Early clinical experience with the new Amplatzer Ductal Occluder II for closure of the persistent arterial duct.
    Forsey J; Kenny D; Morgan G; Hayes A; Turner M; Tometzki A; Martin R
    Catheter Cardiovasc Interv; 2009 Oct; 74(4):615-23. PubMed ID: 19360878
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Transcatheter closure for patent ductus arteriosus in children].
    Shen XQ; Zhou SH; Fang ZF; Hu XQ; Qi SS; Chen GR; Wang C
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2006 Oct; 31(5):782-5. PubMed ID: 17062952
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Unconventional uses of septal occluder devices: Our experience reviewed.
    Awasthy N; Tomar M; Radhakrishnan S; Shrivastava S
    Indian Heart J; 2015; 67(2):128-35. PubMed ID: 26071291
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results.
    Masura J; Walsh KP; Thanopoulous B; Chan C; Bass J; Goussous Y; Gavora P; Hijazi ZM
    J Am Coll Cardiol; 1998 Mar; 31(4):878-82. PubMed ID: 9525563
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of long-term clinical outcome between transcatheter Amplatzer occlusion and surgical closure of isolated patent ductus arteriosus.
    Chen ZY; Wu LM; Luo YK; Lin CG; Peng YF; Zhen XC; Chen LL
    Chin Med J (Engl); 2009 May; 122(10):1123-7. PubMed ID: 19493456
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transthoracic Echocardiography-Guided Percutaneous Patent Ductus Arteriosus Occlusion: A New Strategy for Interventional Treatment.
    Pan XB; Ouyang WB; Wang SZ; Liu Y; Zhang DW; Zhang FW; Pang KJ; Zhang Z; Hu SS
    Echocardiography; 2016 Jul; 33(7):1040-5. PubMed ID: 27038152
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.