167 related articles for article (PubMed ID: 23778400)
61. Measurement of total respiratory impedance in dogs by the forced oscillation technique.
Clercx C; Gustin P; Landser FJ; Van de Woestijne KP
Vet Res Commun; 1993; 17(3):227-39. PubMed ID: 8284900
[TBL] [Abstract][Full Text] [Related]
62. Neonatal total liquid ventilation: is low-frequency forced oscillation technique suitable for respiratory mechanics assessment?
Bossé D; Beaulieu A; Avoine O; Micheau P; Praud JP; Walti H
J Appl Physiol (1985); 2010 Aug; 109(2):501-10. PubMed ID: 20538848
[TBL] [Abstract][Full Text] [Related]
63. Within- and between-day variability of respiratory impedance, using impulse oscillometry in adolescent asthmatics.
Goldman MD; Carter R; Klein R; Fritz G; Carter B; Pachucki P
Pediatr Pulmonol; 2002 Oct; 34(4):312-9. PubMed ID: 12205573
[TBL] [Abstract][Full Text] [Related]
64. Cut-off value of FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction in a Korean population.
Chung KS; Jung JY; Park MS; Kim YS; Kim SK; Chang J; Song JH
Int J Chron Obstruct Pulmon Dis; 2016; 11():1957-63. PubMed ID: 27578970
[TBL] [Abstract][Full Text] [Related]
65. Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.
Farré R; Ferrer M; Rotger M; Navajas D
Eur Respir J; 1995 Jul; 8(7):1222-7. PubMed ID: 7589408
[TBL] [Abstract][Full Text] [Related]
66. Evaluation of respiratory system mechanics in mice using the forced oscillation technique.
McGovern TK; Robichaud A; Fereydoonzad L; Schuessler TF; Martin JG
J Vis Exp; 2013 May; (75):e50172. PubMed ID: 23711876
[TBL] [Abstract][Full Text] [Related]
67. Dynamic versus static respiratory mechanics in acute lung injury and acute respiratory distress syndrome.
Stahl CA; Möller K; Schumann S; Kuhlen R; Sydow M; Putensen C; Guttmann J
Crit Care Med; 2006 Aug; 34(8):2090-8. PubMed ID: 16755254
[TBL] [Abstract][Full Text] [Related]
68. Non-invasive forced oscillometry to quantify respiratory mechanics in term neonates.
Klinger AP; Travers CP; Martin A; Kuo HC; Alishlash AS; Harris WT; Carlo WA; Ambalavanan N
Pediatr Res; 2020 Aug; 88(2):293-299. PubMed ID: 31935746
[TBL] [Abstract][Full Text] [Related]
69. Specificity and sensitivity of respiratory impedance in assessing reversibility of airway obstruction in children.
Mazurek HK; Marchal F; Derelle J; Hatahet R; Moneret-Vautrin D; Monin P
Chest; 1995 Apr; 107(4):996-1002. PubMed ID: 7705167
[TBL] [Abstract][Full Text] [Related]
70. The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV
Li H; Liu C; Zhang Y; Xiao W
Respir Care; 2017 Mar; 62(3):363-369. PubMed ID: 27999150
[TBL] [Abstract][Full Text] [Related]
71. Assessment of pulmonary function in the early phase of ARDS in pediatric patients.
Newth CJ; Stretton M; Deakers TW; Hammer J
Pediatr Pulmonol; 1997 Mar; 23(3):169-75. PubMed ID: 9094724
[TBL] [Abstract][Full Text] [Related]
72. Clinical Significance of Forced Oscillation Technique for Evaluation of Small Airway Disease in Interstitial Lung Diseases.
Mikamo M; Fujisawa T; Oyama Y; Kono M; Enomoto N; Nakamura Y; Inui N; Sumikawa H; Johkoh T; Suda T
Lung; 2016 Dec; 194(6):975-983. PubMed ID: 27734159
[TBL] [Abstract][Full Text] [Related]
73. Effect of methacholine on peripheral lung mechanics and ventilation heterogeneity in asthma.
Downie SR; Salome CM; Verbanck S; Thompson BR; Berend N; King GG
J Appl Physiol (1985); 2013 Mar; 114(6):770-7. PubMed ID: 23372144
[TBL] [Abstract][Full Text] [Related]
74. Evaluation of respiratory impedance in asthma and COPD by an impulse oscillation system.
Kanda S; Fujimoto K; Komatsu Y; Yasuo M; Hanaoka M; Kubo K
Intern Med; 2010; 49(1):23-30. PubMed ID: 20045997
[TBL] [Abstract][Full Text] [Related]
75. A new application of an old method for respiratory mechanics measurements: the passive inflation method in newborn infants during pressure-controlled ventilation.
Storme L; Riou Y; Logier R; Dubos JP; Kacet N; Rousseau S; Lequien P
Pediatr Pulmonol; 1994 Oct; 18(4):244-54. PubMed ID: 7838624
[TBL] [Abstract][Full Text] [Related]
76. Alteration of thiol disulfide homeostasis and ischemia-modified albumin levels as indicators of oxidative status in patients with silicosis.
Karataş M; Büyükşekerci M; Gündüzöz M; Özakıncı G; Öziş TN; Gök G; Neşelioğlu S; Erel Ö
Toxicol Ind Health; 2021 Jan; 37(1):38-46. PubMed ID: 33305688
[TBL] [Abstract][Full Text] [Related]
77. Silicosis: expiratory thin-section CT assessment of airway obstruction.
Arakawa H; Gevenois PA; Saito Y; Shida H; De Maertelaer V; Morikubo H; Fujioka M
Radiology; 2005 Sep; 236(3):1059-66. PubMed ID: 16118178
[TBL] [Abstract][Full Text] [Related]
78. Computer simulation of respiratory impedance and flow transfer functions during high frequency oscillations.
Peslin R
Br J Anaesth; 1989; 63(7 Suppl 1):91S-94S. PubMed ID: 2611083
[TBL] [Abstract][Full Text] [Related]
79. The forced oscillation technique is a sensitive method for detecting obstructive airway disease in patients with primary Sjögren's syndrome.
Nilsson AM; Theander E; Hesselstrand R; Piitulainen E; Wollmer P; Mandl T
Scand J Rheumatol; 2014; 43(4):324-8. PubMed ID: 24392743
[TBL] [Abstract][Full Text] [Related]
80. Tidal changes in respiratory resistance are sensitive indicators of airway obstruction in children.
Czövek D; Shackleton C; Hantos Z; Taylor K; Kumar A; Chacko A; Ware RS; Makan G; Radics B; Gingl Z; Sly PD
Thorax; 2016 Oct; 71(10):907-15. PubMed ID: 27178219
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]