156 related articles for article (PubMed ID: 23782779)
1. [Comparison of dose calculation algorithms in stereotactic radiation therapy in lung].
Tomiyama Y; Araki F; Kanetake N; Shimohigashi Y; Tominaga H; Sakata J; Oono T; Kouno T; Hioki K
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2013 Jun; 69(6):663-8. PubMed ID: 23782779
[TBL] [Abstract][Full Text] [Related]
2. Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions.
Ojala JJ; Kapanen MK; Hyödynmaa SJ; Wigren TK; Pitkänen MA
J Appl Clin Med Phys; 2014 Mar; 15(2):4662. PubMed ID: 24710454
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.
Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M
Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525
[TBL] [Abstract][Full Text] [Related]
4. Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor.
Matsuoka T; Araki F; Ohno T; Sakata J; Tominaga H
Med Dosim; 2019 Autumn; 44(3):284-290. PubMed ID: 30455092
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms.
Ong CCH; Ang KW; Soh RCX; Tin KM; Yap JHH; Lee JCL; Bragg CM
Med Dosim; 2017 Autumn; 42(3):216-222. PubMed ID: 28711478
[TBL] [Abstract][Full Text] [Related]
6. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
7. Use of a second-dose calculation algorithm to check dosimetric parameters for the dose distribution of a first-dose calculation algorithm for lung SBRT plans.
Tsuruta Y; Nakamura M; Miyabe Y; Nakata M; Ishihara Y; Mukumoto N; Akimoto M; Ono T; Yano S; Higashimura K; Matsuo Y; Mizowaki T; Hiraoka M
Phys Med; 2017 Dec; 44():86-95. PubMed ID: 28760507
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of Acuros XB algorithm based on RTOG 0813 dosimetric criteria for SBRT lung treatment with RapidArc.
Rana S; Rogers K; Pokharel S; Cheng C
J Appl Clin Med Phys; 2014 Jan; 15(1):4474. PubMed ID: 24423844
[TBL] [Abstract][Full Text] [Related]
9. A comprehensive evaluation of advanced dose calculation algorithms for brain stereotactic radiosurgery.
Yoon J; Jung H; Tanny SM; Lemus OMD; Milano MT; Hardy SJ; Usuki KY; Zheng D
J Appl Clin Med Phys; 2023 Nov; 24(11):e14169. PubMed ID: 37775989
[TBL] [Abstract][Full Text] [Related]
10. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods.
Mitsuyoshi T; Nakamura M; Matsuo Y; Ueki N; Nakamura A; Iizuka Y; Mampuya WA; Mizowaki T; Hiraoka M
Med Dosim; 2016 Winter; 41(4):305-309. PubMed ID: 27623737
[TBL] [Abstract][Full Text] [Related]
12. Still equivalent for dose calculation in the Monte Carlo era? A comparison of free breathing and average intensity projection CT datasets for lung SBRT using three generations of dose calculation algorithms.
Zvolanek K; Ma R; Zhou C; Liang X; Wang S; Verma V; Zhu X; Zhang Q; Driewer J; Lin C; Zhen W; Wahl A; Zhou SM; Zheng D
Med Phys; 2017 May; 44(5):1939-1947. PubMed ID: 28273341
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate.
Gopalakrishnan Z; Bhasi S; P R; Menon SV; B S; Thayil AG; Nair RK
Med Dosim; 2022 Autumn; 47(3):280-287. PubMed ID: 35690544
[TBL] [Abstract][Full Text] [Related]
14. Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size.
Huang B; Wu L; Lin P; Chen C
Radiat Oncol; 2015 Feb; 10():53. PubMed ID: 25886628
[TBL] [Abstract][Full Text] [Related]
15. Difference in dose-volumetric data between the analytical anisotropic algorithm, the dose-to-medium, and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy.
Mampuya WA; Nakamura M; Hirose Y; Kitsuda K; Ishigaki T; Mizowaki T; Hiraoka M
J Appl Clin Med Phys; 2016 Sep; 17(5):341-347. PubMed ID: 27685138
[TBL] [Abstract][Full Text] [Related]
16. SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.
Bush K; Wang L; Mok E
Med Phys; 2012 Jun; 39(6Part17):3816-3817. PubMed ID: 28517440
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases.
Zhen H; Hrycushko B; Lee H; Timmerman R; Pompoš A; Stojadinovic S; Foster R; Jiang SB; Solberg T; Gu X
J Appl Clin Med Phys; 2015 Jul; 16(4):181–192. PubMed ID: 26219014
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy.
Hirata K; Nakamura M; Yoshimura M; Mukumoto N; Nakata M; Ito H; Inokuchi H; Matsuo Y; Mizowaki T; Hiraoka M
J Appl Clin Med Phys; 2015 Jul; 16(4):52–64. PubMed ID: 26218997
[TBL] [Abstract][Full Text] [Related]
19. Variation of the prescription dose using the analytical anisotropic algorithm in lung stereotactic body radiation therapy.
Kawai D; Takahashi R; Kamima T; Baba H; Yamamoto T; Kubo Y; Ishibashi S; Higuchi Y; Tani K; Mizuno N; Jinno S; Tachibana H
Phys Med; 2017 Jun; 38():98-104. PubMed ID: 28610704
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric comparison of different algorithms in stereotactic body radiation therapy (SBRT) plan for non-small cell lung cancer (NSCLC).
Zhang J; Jiang D; Su H; Dai Z; Dai J; Liu H; Xie C; Yu H
Onco Targets Ther; 2019; 12():6385-6391. PubMed ID: 31496740
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]